Intraoperative electromyography during thoracolumbar spinal surgery

Intraoperative electromyography can provide useful information regarding lumbosacral nerve root function during thoracolumbar spinal surgery. Free-running electromyography provides continuous feedback regarding the location and potential for surgical injury to the lumbosacral nerve roots within the...

Full description

Saved in:
Bibliographic Details
Published in:Spine (Philadelphia, Pa. 1976) Pa. 1976), 1998-09, Vol.23 (17), p.1915-1922
Main Author: Holland, N R
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03
cites cdi_FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03
container_end_page 1922
container_issue 17
container_start_page 1915
container_title Spine (Philadelphia, Pa. 1976)
container_volume 23
creator Holland, N R
description Intraoperative electromyography can provide useful information regarding lumbosacral nerve root function during thoracolumbar spinal surgery. Free-running electromyography provides continuous feedback regarding the location and potential for surgical injury to the lumbosacral nerve roots within the operative field. Stimulus-evoked electromyography can confirm that transpedicular instrumentation has been positioned correctly within the bony cortex. However, electromyography has a number of potential limitations, which are discussed in this article along with improved methods to increase the overall efficacy of intraoperative electromyography, including: 1) Electromyography is sensitive to blunt lumbosacral nerve root irritation or injury, but may provide misleading results with "clean" nerve root transection. 2) Electromyography must be recorded from muscles belonging to myotomes appropriate for the nerve roots considered at risk from surgery. 3) Electromyography can be effective only with careful monitoring and titration of pharmacologic neuromuscular junction blockade. 4) When transpedicular instrumentation is stimulated, an exposed nerve root should be stimulated directly as a positive control whenever possible. 5) Pedicle holes and screws should be stimulated with single shocks at low-stimulus intensities when pharmacologic neuromuscular blockade is excessive. 6) Chronically compressed nerve roots that have undergone axonotmesis (wallerian degeneration) have higher thresholds for activation from electrical and mechanical stimulation. 7) Hence, whenever axonotmetic nerve root injury is suspected, the stimulus thresholds for transpedicular holes and screws must be specifically compared with those required for the direct activation of the adjacent nerve root (and not published guideline threshold values).
doi_str_mv 10.1097/00007632-199809010-00023
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_73941278</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73941278</sourcerecordid><originalsourceid>FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03</originalsourceid><addsrcrecordid>eNo9kEtPwzAQhH0AlVL4CUg5cQv4kcTxEVU8KlXiAmdr66zboCQO6wQp_54ApXNZaTSzI32MJYLfCW70PZ-lCyVTYUzJDRc8nR2pztiSq0KmMlPFBbuM8WO2CyXMgi2MLqTOxZKtN91AEHokGOovTLBBN1Bop7An6A9TUo1Ud_tkOAQCF5qx3QElsa87aJI40h5pumLnHpqI18e7Yu9Pj2_rl3T7-rxZP2xTpwQf0tJk4AwomUntAAonMPMoMoS8kJUA3OUowHssvQKtK6e0cabKEbnypedqxW7__vYUPkeMg23r6LBpoMMwRquVyYTU5Rws_4KOQoyE3vZUt0CTFdz-MLP_zOyJmf1lNldvjhvjrsXqVDwCU999SGvZ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73941278</pqid></control><display><type>article</type><title>Intraoperative electromyography during thoracolumbar spinal surgery</title><source>HEAL-Link subscriptions: Lippincott Williams &amp; Wilkins</source><creator>Holland, N R</creator><creatorcontrib>Holland, N R</creatorcontrib><description>Intraoperative electromyography can provide useful information regarding lumbosacral nerve root function during thoracolumbar spinal surgery. Free-running electromyography provides continuous feedback regarding the location and potential for surgical injury to the lumbosacral nerve roots within the operative field. Stimulus-evoked electromyography can confirm that transpedicular instrumentation has been positioned correctly within the bony cortex. However, electromyography has a number of potential limitations, which are discussed in this article along with improved methods to increase the overall efficacy of intraoperative electromyography, including: 1) Electromyography is sensitive to blunt lumbosacral nerve root irritation or injury, but may provide misleading results with "clean" nerve root transection. 2) Electromyography must be recorded from muscles belonging to myotomes appropriate for the nerve roots considered at risk from surgery. 3) Electromyography can be effective only with careful monitoring and titration of pharmacologic neuromuscular junction blockade. 4) When transpedicular instrumentation is stimulated, an exposed nerve root should be stimulated directly as a positive control whenever possible. 5) Pedicle holes and screws should be stimulated with single shocks at low-stimulus intensities when pharmacologic neuromuscular blockade is excessive. 6) Chronically compressed nerve roots that have undergone axonotmesis (wallerian degeneration) have higher thresholds for activation from electrical and mechanical stimulation. 7) Hence, whenever axonotmetic nerve root injury is suspected, the stimulus thresholds for transpedicular holes and screws must be specifically compared with those required for the direct activation of the adjacent nerve root (and not published guideline threshold values).</description><identifier>ISSN: 0362-2436</identifier><identifier>DOI: 10.1097/00007632-199809010-00023</identifier><identifier>PMID: 9762751</identifier><language>eng</language><publisher>United States</publisher><subject>Electromyography - methods ; Humans ; Lumbar Vertebrae - surgery ; Monitoring, Intraoperative - methods ; Spinal Fusion ; Thoracic Vertebrae - surgery</subject><ispartof>Spine (Philadelphia, Pa. 1976), 1998-09, Vol.23 (17), p.1915-1922</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03</citedby><cites>FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9762751$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Holland, N R</creatorcontrib><title>Intraoperative electromyography during thoracolumbar spinal surgery</title><title>Spine (Philadelphia, Pa. 1976)</title><addtitle>Spine (Phila Pa 1976)</addtitle><description>Intraoperative electromyography can provide useful information regarding lumbosacral nerve root function during thoracolumbar spinal surgery. Free-running electromyography provides continuous feedback regarding the location and potential for surgical injury to the lumbosacral nerve roots within the operative field. Stimulus-evoked electromyography can confirm that transpedicular instrumentation has been positioned correctly within the bony cortex. However, electromyography has a number of potential limitations, which are discussed in this article along with improved methods to increase the overall efficacy of intraoperative electromyography, including: 1) Electromyography is sensitive to blunt lumbosacral nerve root irritation or injury, but may provide misleading results with "clean" nerve root transection. 2) Electromyography must be recorded from muscles belonging to myotomes appropriate for the nerve roots considered at risk from surgery. 3) Electromyography can be effective only with careful monitoring and titration of pharmacologic neuromuscular junction blockade. 4) When transpedicular instrumentation is stimulated, an exposed nerve root should be stimulated directly as a positive control whenever possible. 5) Pedicle holes and screws should be stimulated with single shocks at low-stimulus intensities when pharmacologic neuromuscular blockade is excessive. 6) Chronically compressed nerve roots that have undergone axonotmesis (wallerian degeneration) have higher thresholds for activation from electrical and mechanical stimulation. 7) Hence, whenever axonotmetic nerve root injury is suspected, the stimulus thresholds for transpedicular holes and screws must be specifically compared with those required for the direct activation of the adjacent nerve root (and not published guideline threshold values).</description><subject>Electromyography - methods</subject><subject>Humans</subject><subject>Lumbar Vertebrae - surgery</subject><subject>Monitoring, Intraoperative - methods</subject><subject>Spinal Fusion</subject><subject>Thoracic Vertebrae - surgery</subject><issn>0362-2436</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNo9kEtPwzAQhH0AlVL4CUg5cQv4kcTxEVU8KlXiAmdr66zboCQO6wQp_54ApXNZaTSzI32MJYLfCW70PZ-lCyVTYUzJDRc8nR2pztiSq0KmMlPFBbuM8WO2CyXMgi2MLqTOxZKtN91AEHokGOovTLBBN1Bop7An6A9TUo1Ud_tkOAQCF5qx3QElsa87aJI40h5pumLnHpqI18e7Yu9Pj2_rl3T7-rxZP2xTpwQf0tJk4AwomUntAAonMPMoMoS8kJUA3OUowHssvQKtK6e0cabKEbnypedqxW7__vYUPkeMg23r6LBpoMMwRquVyYTU5Rws_4KOQoyE3vZUt0CTFdz-MLP_zOyJmf1lNldvjhvjrsXqVDwCU999SGvZ</recordid><startdate>19980901</startdate><enddate>19980901</enddate><creator>Holland, N R</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19980901</creationdate><title>Intraoperative electromyography during thoracolumbar spinal surgery</title><author>Holland, N R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Electromyography - methods</topic><topic>Humans</topic><topic>Lumbar Vertebrae - surgery</topic><topic>Monitoring, Intraoperative - methods</topic><topic>Spinal Fusion</topic><topic>Thoracic Vertebrae - surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Holland, N R</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Holland, N R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Intraoperative electromyography during thoracolumbar spinal surgery</atitle><jtitle>Spine (Philadelphia, Pa. 1976)</jtitle><addtitle>Spine (Phila Pa 1976)</addtitle><date>1998-09-01</date><risdate>1998</risdate><volume>23</volume><issue>17</issue><spage>1915</spage><epage>1922</epage><pages>1915-1922</pages><issn>0362-2436</issn><abstract>Intraoperative electromyography can provide useful information regarding lumbosacral nerve root function during thoracolumbar spinal surgery. Free-running electromyography provides continuous feedback regarding the location and potential for surgical injury to the lumbosacral nerve roots within the operative field. Stimulus-evoked electromyography can confirm that transpedicular instrumentation has been positioned correctly within the bony cortex. However, electromyography has a number of potential limitations, which are discussed in this article along with improved methods to increase the overall efficacy of intraoperative electromyography, including: 1) Electromyography is sensitive to blunt lumbosacral nerve root irritation or injury, but may provide misleading results with "clean" nerve root transection. 2) Electromyography must be recorded from muscles belonging to myotomes appropriate for the nerve roots considered at risk from surgery. 3) Electromyography can be effective only with careful monitoring and titration of pharmacologic neuromuscular junction blockade. 4) When transpedicular instrumentation is stimulated, an exposed nerve root should be stimulated directly as a positive control whenever possible. 5) Pedicle holes and screws should be stimulated with single shocks at low-stimulus intensities when pharmacologic neuromuscular blockade is excessive. 6) Chronically compressed nerve roots that have undergone axonotmesis (wallerian degeneration) have higher thresholds for activation from electrical and mechanical stimulation. 7) Hence, whenever axonotmetic nerve root injury is suspected, the stimulus thresholds for transpedicular holes and screws must be specifically compared with those required for the direct activation of the adjacent nerve root (and not published guideline threshold values).</abstract><cop>United States</cop><pmid>9762751</pmid><doi>10.1097/00007632-199809010-00023</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0362-2436
ispartof Spine (Philadelphia, Pa. 1976), 1998-09, Vol.23 (17), p.1915-1922
issn 0362-2436
language eng
recordid cdi_proquest_miscellaneous_73941278
source HEAL-Link subscriptions: Lippincott Williams & Wilkins
subjects Electromyography - methods
Humans
Lumbar Vertebrae - surgery
Monitoring, Intraoperative - methods
Spinal Fusion
Thoracic Vertebrae - surgery
title Intraoperative electromyography during thoracolumbar spinal surgery
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-10T02%3A48%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Intraoperative%20electromyography%20during%20thoracolumbar%20spinal%20surgery&rft.jtitle=Spine%20(Philadelphia,%20Pa.%201976)&rft.au=Holland,%20N%20R&rft.date=1998-09-01&rft.volume=23&rft.issue=17&rft.spage=1915&rft.epage=1922&rft.pages=1915-1922&rft.issn=0362-2436&rft_id=info:doi/10.1097/00007632-199809010-00023&rft_dat=%3Cproquest_cross%3E73941278%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c310t-894ac9a32427caa6c1e4fe14ea562d1aeb5e1affe8f3a77dc379c9d5ee03f8f03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=73941278&rft_id=info:pmid/9762751&rfr_iscdi=true