The difference between visual and instrumental analyses of a shade selection on natural teeth was investigated. With visual analysis, five prosthodontist examined the middle third of the unrestored maxillary right central incisor of a patient using VITAPEN classical and Vita Toothguide 3D-MASTER t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Wuhan University of Technology. Materials science edition 2010-02, Vol.25 (1), p.62-67
Main Authors: Choi, Jee-Ha, Park, Ju-Mi, Ahn, Seung-Geun, Song, Kwang-Yeob, Lee, Min-Ho, Jung, Jae-Youn, Wang, Xinyu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The difference between visual and instrumental analyses of a shade selection on natural teeth was investigated. With visual analysis, five prosthodontist examined the middle third of the unrestored maxillary right central incisor of a patient using VITAPEN classical and Vita Toothguide 3D-MASTER tooth shade guide. In instrumental analysis, one prosthodontist examined the same teeth using a spectrophotometer (ShadepilotTM, Degudent, Hanau-Wolfgang, Germany, software 2.40). Overall, instrumental analysis is more accurate and reproducible than a visual assessment. However, the difference is clinically acceptable.