Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility

A facility for the monochromator-based calibration of transfer standard detectors using a cryogenic radiometer has been set up at the National Research Council of Canada (NRC). A brief status report is given on this facility, which has undergone some modifications since it was first set up in 1994....

Full description

Saved in:
Bibliographic Details
Published in:Metrologia 1998-08, Vol.35 (4), p.363-368
Main Author: Boivin, L P
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3
cites cdi_FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3
container_end_page 368
container_issue 4
container_start_page 363
container_title Metrologia
container_volume 35
creator Boivin, L P
description A facility for the monochromator-based calibration of transfer standard detectors using a cryogenic radiometer has been set up at the National Research Council of Canada (NRC). A brief status report is given on this facility, which has undergone some modifications since it was first set up in 1994. Measurements so far have concentrated on the spectral range 450 nm to 700 nm. The wavelength calibration of the monochromator used with this facility is discussed in detail. Two types of transfer radiometer have been developed for use with the cryogenic radiometer. The original radiometers use a single photodiode and incorporate a quartz window. The second type of radiometer is a windowless three-detector trap using special 18 mm properties of these two types of transfer radiometer are compared: spectral responsivity, uniformity, polarization sensitivity, and linearity. Results of calibrations of these radiometers over one to two years are presented. These measurements suggest that the long-term reproducibility of the calibrations is approximately 0.025% for a single radiometer, but close to 0.01% for a group of radiometers. The transfer radiometers can be used to calibrate accurately other detectors using auxiliary apparatus. Measurements are presented which suggest that the transfer uncertainty is close to 0.01% on average. The accuracy of the cryogenic-radiometer-based calibrations can be estimated by linking them to the international comparison of spectral-responsivity scales carried out at the Bureau International des Poids et Mesures in 1994 under the auspices of the Consultative Committee for Photometry and Radiometry (CCPR). From this comparison, it is estimated that the overall accuracy of the cryogenic radiometer calibrations is better than 0.05% in the range 450 nm to 700 nm. 18 mm silicon photodiodes. Some of the
doi_str_mv 10.1088/0026-1394/35/4/24
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_743310336</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>743310336</sourcerecordid><originalsourceid>FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3</originalsourceid><addsrcrecordid>eNp1kD1PwzAQhj2ARCn8ADZvMBDqzyYZUcWXVMQCs-U452KUxMF2QPn3pCqqkCqmO9097zs8CF1QckNJUSwIYcuM8lIsuFyIBRNHaLa_naDTGD8IoTmT-QwNz6DjEKCFLkU8RNdtcPr2OI09ROwtTkF30ULAQdfOt5CmtYYvaHwPNbY-YI1b33nzHnyrkw9ZpeP0MWH0G-ic-Ru02rjGpfEMHVvdRDj_nXP0dn_3unrM1i8PT6vbdWYEKVMmNSFQ1rmRltZsWXFelkxKwYSVBVhCapAFAw2CVlTXRQlWSENFZSWRlFd8ji53vX3wnwPEpFoXDTSN7sAPUeWCc0o4X04k3ZEm-BgDWNUH1-owKkrU1qraGlRbg4pLJRQTU-Zql3G-3-MHmOprO6HXh-j_zT_M_IlK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>743310336</pqid></control><display><type>article</type><title>Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility</title><source>Institute of Physics:Jisc Collections:IOP Publishing Journal Archive 1874-1998 (access period 2020 to 2024)</source><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Boivin, L P</creator><creatorcontrib>Boivin, L P</creatorcontrib><description>A facility for the monochromator-based calibration of transfer standard detectors using a cryogenic radiometer has been set up at the National Research Council of Canada (NRC). A brief status report is given on this facility, which has undergone some modifications since it was first set up in 1994. Measurements so far have concentrated on the spectral range 450 nm to 700 nm. The wavelength calibration of the monochromator used with this facility is discussed in detail. Two types of transfer radiometer have been developed for use with the cryogenic radiometer. The original radiometers use a single photodiode and incorporate a quartz window. The second type of radiometer is a windowless three-detector trap using special 18 mm properties of these two types of transfer radiometer are compared: spectral responsivity, uniformity, polarization sensitivity, and linearity. Results of calibrations of these radiometers over one to two years are presented. These measurements suggest that the long-term reproducibility of the calibrations is approximately 0.025% for a single radiometer, but close to 0.01% for a group of radiometers. The transfer radiometers can be used to calibrate accurately other detectors using auxiliary apparatus. Measurements are presented which suggest that the transfer uncertainty is close to 0.01% on average. The accuracy of the cryogenic-radiometer-based calibrations can be estimated by linking them to the international comparison of spectral-responsivity scales carried out at the Bureau International des Poids et Mesures in 1994 under the auspices of the Consultative Committee for Photometry and Radiometry (CCPR). From this comparison, it is estimated that the overall accuracy of the cryogenic radiometer calibrations is better than 0.05% in the range 450 nm to 700 nm. 18 mm silicon photodiodes. Some of the</description><identifier>ISSN: 0026-1394</identifier><identifier>DOI: 10.1088/0026-1394/35/4/24</identifier><language>eng</language><publisher>IOP Publishing</publisher><ispartof>Metrologia, 1998-08, Vol.35 (4), p.363-368</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3</citedby><cites>FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0026-1394/35/4/24/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53925</link.rule.ids></links><search><creatorcontrib>Boivin, L P</creatorcontrib><title>Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility</title><title>Metrologia</title><description>A facility for the monochromator-based calibration of transfer standard detectors using a cryogenic radiometer has been set up at the National Research Council of Canada (NRC). A brief status report is given on this facility, which has undergone some modifications since it was first set up in 1994. Measurements so far have concentrated on the spectral range 450 nm to 700 nm. The wavelength calibration of the monochromator used with this facility is discussed in detail. Two types of transfer radiometer have been developed for use with the cryogenic radiometer. The original radiometers use a single photodiode and incorporate a quartz window. The second type of radiometer is a windowless three-detector trap using special 18 mm properties of these two types of transfer radiometer are compared: spectral responsivity, uniformity, polarization sensitivity, and linearity. Results of calibrations of these radiometers over one to two years are presented. These measurements suggest that the long-term reproducibility of the calibrations is approximately 0.025% for a single radiometer, but close to 0.01% for a group of radiometers. The transfer radiometers can be used to calibrate accurately other detectors using auxiliary apparatus. Measurements are presented which suggest that the transfer uncertainty is close to 0.01% on average. The accuracy of the cryogenic-radiometer-based calibrations can be estimated by linking them to the international comparison of spectral-responsivity scales carried out at the Bureau International des Poids et Mesures in 1994 under the auspices of the Consultative Committee for Photometry and Radiometry (CCPR). From this comparison, it is estimated that the overall accuracy of the cryogenic radiometer calibrations is better than 0.05% in the range 450 nm to 700 nm. 18 mm silicon photodiodes. Some of the</description><issn>0026-1394</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNp1kD1PwzAQhj2ARCn8ADZvMBDqzyYZUcWXVMQCs-U452KUxMF2QPn3pCqqkCqmO9097zs8CF1QckNJUSwIYcuM8lIsuFyIBRNHaLa_naDTGD8IoTmT-QwNz6DjEKCFLkU8RNdtcPr2OI09ROwtTkF30ULAQdfOt5CmtYYvaHwPNbY-YI1b33nzHnyrkw9ZpeP0MWH0G-ic-Ru02rjGpfEMHVvdRDj_nXP0dn_3unrM1i8PT6vbdWYEKVMmNSFQ1rmRltZsWXFelkxKwYSVBVhCapAFAw2CVlTXRQlWSENFZSWRlFd8ji53vX3wnwPEpFoXDTSN7sAPUeWCc0o4X04k3ZEm-BgDWNUH1-owKkrU1qraGlRbg4pLJRQTU-Zql3G-3-MHmOprO6HXh-j_zT_M_IlK</recordid><startdate>19980801</startdate><enddate>19980801</enddate><creator>Boivin, L P</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>19980801</creationdate><title>Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility</title><author>Boivin, L P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boivin, L P</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Metrologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boivin, L P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility</atitle><jtitle>Metrologia</jtitle><date>1998-08-01</date><risdate>1998</risdate><volume>35</volume><issue>4</issue><spage>363</spage><epage>368</epage><pages>363-368</pages><issn>0026-1394</issn><abstract>A facility for the monochromator-based calibration of transfer standard detectors using a cryogenic radiometer has been set up at the National Research Council of Canada (NRC). A brief status report is given on this facility, which has undergone some modifications since it was first set up in 1994. Measurements so far have concentrated on the spectral range 450 nm to 700 nm. The wavelength calibration of the monochromator used with this facility is discussed in detail. Two types of transfer radiometer have been developed for use with the cryogenic radiometer. The original radiometers use a single photodiode and incorporate a quartz window. The second type of radiometer is a windowless three-detector trap using special 18 mm properties of these two types of transfer radiometer are compared: spectral responsivity, uniformity, polarization sensitivity, and linearity. Results of calibrations of these radiometers over one to two years are presented. These measurements suggest that the long-term reproducibility of the calibrations is approximately 0.025% for a single radiometer, but close to 0.01% for a group of radiometers. The transfer radiometers can be used to calibrate accurately other detectors using auxiliary apparatus. Measurements are presented which suggest that the transfer uncertainty is close to 0.01% on average. The accuracy of the cryogenic-radiometer-based calibrations can be estimated by linking them to the international comparison of spectral-responsivity scales carried out at the Bureau International des Poids et Mesures in 1994 under the auspices of the Consultative Committee for Photometry and Radiometry (CCPR). From this comparison, it is estimated that the overall accuracy of the cryogenic radiometer calibrations is better than 0.05% in the range 450 nm to 700 nm. 18 mm silicon photodiodes. Some of the</abstract><pub>IOP Publishing</pub><doi>10.1088/0026-1394/35/4/24</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0026-1394
ispartof Metrologia, 1998-08, Vol.35 (4), p.363-368
issn 0026-1394
language eng
recordid cdi_proquest_miscellaneous_743310336
source Institute of Physics:Jisc Collections:IOP Publishing Journal Archive 1874-1998 (access period 2020 to 2024); Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)
title Measurements using two types of transfer radiometer developed for a monochromator-based cryogenic radiometer facility
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T07%3A02%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurements%20using%20two%20types%20of%20transfer%20radiometer%20developed%20for%20a%20monochromator-based%20cryogenic%20radiometer%20facility&rft.jtitle=Metrologia&rft.au=Boivin,%20L%20P&rft.date=1998-08-01&rft.volume=35&rft.issue=4&rft.spage=363&rft.epage=368&rft.pages=363-368&rft.issn=0026-1394&rft_id=info:doi/10.1088/0026-1394/35/4/24&rft_dat=%3Cproquest_cross%3E743310336%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c409t-5a00e9d7c5f1d26b3399255424f58ef00de582eae41b1ad89ef45c14bf50513b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=743310336&rft_id=info:pmid/&rfr_iscdi=true