Loading…
Improved B sub(0) field map estimation for high field EPI
Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To...
Saved in:
Published in: | Magnetic resonance imaging 2010-04, Vol.28 (3), p.441-450 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 450 |
container_issue | 3 |
container_start_page | 441 |
container_title | Magnetic resonance imaging |
container_volume | 28 |
creator | Poot, Dirk HJ Pintjens, Wouter Verhoye, Marleen Van der Linden, Annemie Sijbers, Jan |
description | Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B sub(0) field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method. |
doi_str_mv | 10.1016/j.mri.2009.12.020 |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_746302695</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>746302695</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_7463026953</originalsourceid><addsrcrecordid>eNqNjL0OgjAYRTtoIv48gFs3dbB-bS2EVYORzcHBjVQpUtJSpODzy8ADON3hnHMRWlMgFGh4qIhtNWEAMaGMAIMJCiDisI-YeMzQ3PsKAATjIkBxapvWfVWOT9j3zy3scKGVybGVDVa-01Z22tW4cC0u9bscaXJLl2haSOPVatwF2lyS-_m6H_4-_ZBmVvuXMkbWyvU-i44hBxbGgv9v_gDFyT3R</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>746302695</pqid></control><display><type>article</type><title>Improved B sub(0) field map estimation for high field EPI</title><source>ScienceDirect Freedom Collection</source><creator>Poot, Dirk HJ ; Pintjens, Wouter ; Verhoye, Marleen ; Van der Linden, Annemie ; Sijbers, Jan</creator><creatorcontrib>Poot, Dirk HJ ; Pintjens, Wouter ; Verhoye, Marleen ; Van der Linden, Annemie ; Sijbers, Jan</creatorcontrib><description>Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B sub(0) field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.</description><identifier>ISSN: 0730-725X</identifier><identifier>DOI: 10.1016/j.mri.2009.12.020</identifier><language>eng</language><ispartof>Magnetic resonance imaging, 2010-04, Vol.28 (3), p.441-450</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Poot, Dirk HJ</creatorcontrib><creatorcontrib>Pintjens, Wouter</creatorcontrib><creatorcontrib>Verhoye, Marleen</creatorcontrib><creatorcontrib>Van der Linden, Annemie</creatorcontrib><creatorcontrib>Sijbers, Jan</creatorcontrib><title>Improved B sub(0) field map estimation for high field EPI</title><title>Magnetic resonance imaging</title><description>Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B sub(0) field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.</description><issn>0730-725X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqNjL0OgjAYRTtoIv48gFs3dbB-bS2EVYORzcHBjVQpUtJSpODzy8ADON3hnHMRWlMgFGh4qIhtNWEAMaGMAIMJCiDisI-YeMzQ3PsKAATjIkBxapvWfVWOT9j3zy3scKGVybGVDVa-01Z22tW4cC0u9bscaXJLl2haSOPVatwF2lyS-_m6H_4-_ZBmVvuXMkbWyvU-i44hBxbGgv9v_gDFyT3R</recordid><startdate>20100401</startdate><enddate>20100401</enddate><creator>Poot, Dirk HJ</creator><creator>Pintjens, Wouter</creator><creator>Verhoye, Marleen</creator><creator>Van der Linden, Annemie</creator><creator>Sijbers, Jan</creator><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20100401</creationdate><title>Improved B sub(0) field map estimation for high field EPI</title><author>Poot, Dirk HJ ; Pintjens, Wouter ; Verhoye, Marleen ; Van der Linden, Annemie ; Sijbers, Jan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_7463026953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Poot, Dirk HJ</creatorcontrib><creatorcontrib>Pintjens, Wouter</creatorcontrib><creatorcontrib>Verhoye, Marleen</creatorcontrib><creatorcontrib>Van der Linden, Annemie</creatorcontrib><creatorcontrib>Sijbers, Jan</creatorcontrib><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Magnetic resonance imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Poot, Dirk HJ</au><au>Pintjens, Wouter</au><au>Verhoye, Marleen</au><au>Van der Linden, Annemie</au><au>Sijbers, Jan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Improved B sub(0) field map estimation for high field EPI</atitle><jtitle>Magnetic resonance imaging</jtitle><date>2010-04-01</date><risdate>2010</risdate><volume>28</volume><issue>3</issue><spage>441</spage><epage>450</epage><pages>441-450</pages><issn>0730-725X</issn><abstract>Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B sub(0) field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.</abstract><doi>10.1016/j.mri.2009.12.020</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0730-725X |
ispartof | Magnetic resonance imaging, 2010-04, Vol.28 (3), p.441-450 |
issn | 0730-725X |
language | eng |
recordid | cdi_proquest_miscellaneous_746302695 |
source | ScienceDirect Freedom Collection |
title | Improved B sub(0) field map estimation for high field EPI |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T13%3A39%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Improved%20B%20sub(0)%20field%20map%20estimation%20for%20high%20field%20EPI&rft.jtitle=Magnetic%20resonance%20imaging&rft.au=Poot,%20Dirk%20HJ&rft.date=2010-04-01&rft.volume=28&rft.issue=3&rft.spage=441&rft.epage=450&rft.pages=441-450&rft.issn=0730-725X&rft_id=info:doi/10.1016/j.mri.2009.12.020&rft_dat=%3Cproquest%3E746302695%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_7463026953%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=746302695&rft_id=info:pmid/&rfr_iscdi=true |