Loading…

A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis

For the experimental studies on chronic coronary stenosis, an ameroid constrictor was modified to facilitate serial cineangiographic evaluation of the degree of arterial narrowing. A radiolucent plastic ring instead of a stainless frame was used to prevent outward swelling of the ameroid material. C...

Full description

Saved in:
Bibliographic Details
Published in:Basic research in cardiology 1980-07, Vol.75 (4), p.537-543
Main Authors: Inou, T, Tomoike, H, Watanabe, K, Kikuchi, Y, Mizukami, M, Kurozumi, T, Nakamura, M
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493
cites cdi_FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493
container_end_page 543
container_issue 4
container_start_page 537
container_title Basic research in cardiology
container_volume 75
creator Inou, T
Tomoike, H
Watanabe, K
Kikuchi, Y
Mizukami, M
Kurozumi, T
Nakamura, M
description For the experimental studies on chronic coronary stenosis, an ameroid constrictor was modified to facilitate serial cineangiographic evaluation of the degree of arterial narrowing. A radiolucent plastic ring instead of a stainless frame was used to prevent outward swelling of the ameroid material. Coronary cineangiography was performed 10, 20 and 30 days after the implantation of the modified ameroid constrictor on the left circumflex coronary artery (LCX), which could prove the progressive coronary stenosis of 57, 78 and 88% on the respective days. Collateral channels from the anterior descending branch of the left coronary artery to the LCX were demonstrated angiographically in 5 out of the 6 dogs on the 30th day.
doi_str_mv 10.1007/BF01907835
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75340789</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75340789</sourcerecordid><originalsourceid>FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493</originalsourceid><addsrcrecordid>eNpFkMFLwzAUh4Moc04v3oWcPAjVpEma5jiHU2HgRcFbSZPXUWmTmbRK_3sjG3p4vAfv48ePD6FLSm4pIfLufk2oIrJk4gjNKWcioyVhx2hOGCFZyfPyFJ3F-EEI5UVBZ2gmOSuUknPUL7GD727CFr6g8zuw-D0LesJD0C7udAA3YN1D8K3Fxrs4hNYMPuAmTRxGO2Hv8C74bYAY23T7Bm-DtqPuEh-802FKIDgf23iOThrdRbg47AV6Wz-8rp6yzcvj82q5yUxe5kNWCyPyklPbMCIYZUTVSrO6KA1Io5RQAoSgrJY2B6o4y0VeC-ClTO_CcMUW6Hqfm4p9jhCHqm-jga7TDvwYKykYT75-wZs9aIKPMUBT7ULbp8oVJdWv2-rfbYKvDqlj3YP9Qw8y2Q_XuXT6</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75340789</pqid></control><display><type>article</type><title>A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis</title><source>Springer LINK Archives</source><creator>Inou, T ; Tomoike, H ; Watanabe, K ; Kikuchi, Y ; Mizukami, M ; Kurozumi, T ; Nakamura, M</creator><creatorcontrib>Inou, T ; Tomoike, H ; Watanabe, K ; Kikuchi, Y ; Mizukami, M ; Kurozumi, T ; Nakamura, M</creatorcontrib><description>For the experimental studies on chronic coronary stenosis, an ameroid constrictor was modified to facilitate serial cineangiographic evaluation of the degree of arterial narrowing. A radiolucent plastic ring instead of a stainless frame was used to prevent outward swelling of the ameroid material. Coronary cineangiography was performed 10, 20 and 30 days after the implantation of the modified ameroid constrictor on the left circumflex coronary artery (LCX), which could prove the progressive coronary stenosis of 57, 78 and 88% on the respective days. Collateral channels from the anterior descending branch of the left coronary artery to the LCX were demonstrated angiographically in 5 out of the 6 dogs on the 30th day.</description><identifier>ISSN: 0300-8428</identifier><identifier>EISSN: 1435-1803</identifier><identifier>DOI: 10.1007/BF01907835</identifier><identifier>PMID: 7436997</identifier><language>eng</language><publisher>Germany</publisher><subject>Animals ; Arteries - pathology ; Constriction ; Coronary Angiography ; Coronary Disease - diagnostic imaging ; Coronary Disease - etiology ; Coronary Disease - pathology ; Coronary Vessels - pathology ; Dogs ; Plastics</subject><ispartof>Basic research in cardiology, 1980-07, Vol.75 (4), p.537-543</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493</citedby><cites>FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7436997$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Inou, T</creatorcontrib><creatorcontrib>Tomoike, H</creatorcontrib><creatorcontrib>Watanabe, K</creatorcontrib><creatorcontrib>Kikuchi, Y</creatorcontrib><creatorcontrib>Mizukami, M</creatorcontrib><creatorcontrib>Kurozumi, T</creatorcontrib><creatorcontrib>Nakamura, M</creatorcontrib><title>A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis</title><title>Basic research in cardiology</title><addtitle>Basic Res Cardiol</addtitle><description>For the experimental studies on chronic coronary stenosis, an ameroid constrictor was modified to facilitate serial cineangiographic evaluation of the degree of arterial narrowing. A radiolucent plastic ring instead of a stainless frame was used to prevent outward swelling of the ameroid material. Coronary cineangiography was performed 10, 20 and 30 days after the implantation of the modified ameroid constrictor on the left circumflex coronary artery (LCX), which could prove the progressive coronary stenosis of 57, 78 and 88% on the respective days. Collateral channels from the anterior descending branch of the left coronary artery to the LCX were demonstrated angiographically in 5 out of the 6 dogs on the 30th day.</description><subject>Animals</subject><subject>Arteries - pathology</subject><subject>Constriction</subject><subject>Coronary Angiography</subject><subject>Coronary Disease - diagnostic imaging</subject><subject>Coronary Disease - etiology</subject><subject>Coronary Disease - pathology</subject><subject>Coronary Vessels - pathology</subject><subject>Dogs</subject><subject>Plastics</subject><issn>0300-8428</issn><issn>1435-1803</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1980</creationdate><recordtype>article</recordtype><recordid>eNpFkMFLwzAUh4Moc04v3oWcPAjVpEma5jiHU2HgRcFbSZPXUWmTmbRK_3sjG3p4vAfv48ePD6FLSm4pIfLufk2oIrJk4gjNKWcioyVhx2hOGCFZyfPyFJ3F-EEI5UVBZ2gmOSuUknPUL7GD727CFr6g8zuw-D0LesJD0C7udAA3YN1D8K3Fxrs4hNYMPuAmTRxGO2Hv8C74bYAY23T7Bm-DtqPuEh-802FKIDgf23iOThrdRbg47AV6Wz-8rp6yzcvj82q5yUxe5kNWCyPyklPbMCIYZUTVSrO6KA1Io5RQAoSgrJY2B6o4y0VeC-ClTO_CcMUW6Hqfm4p9jhCHqm-jga7TDvwYKykYT75-wZs9aIKPMUBT7ULbp8oVJdWv2-rfbYKvDqlj3YP9Qw8y2Q_XuXT6</recordid><startdate>198007</startdate><enddate>198007</enddate><creator>Inou, T</creator><creator>Tomoike, H</creator><creator>Watanabe, K</creator><creator>Kikuchi, Y</creator><creator>Mizukami, M</creator><creator>Kurozumi, T</creator><creator>Nakamura, M</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198007</creationdate><title>A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis</title><author>Inou, T ; Tomoike, H ; Watanabe, K ; Kikuchi, Y ; Mizukami, M ; Kurozumi, T ; Nakamura, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1980</creationdate><topic>Animals</topic><topic>Arteries - pathology</topic><topic>Constriction</topic><topic>Coronary Angiography</topic><topic>Coronary Disease - diagnostic imaging</topic><topic>Coronary Disease - etiology</topic><topic>Coronary Disease - pathology</topic><topic>Coronary Vessels - pathology</topic><topic>Dogs</topic><topic>Plastics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Inou, T</creatorcontrib><creatorcontrib>Tomoike, H</creatorcontrib><creatorcontrib>Watanabe, K</creatorcontrib><creatorcontrib>Kikuchi, Y</creatorcontrib><creatorcontrib>Mizukami, M</creatorcontrib><creatorcontrib>Kurozumi, T</creatorcontrib><creatorcontrib>Nakamura, M</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Basic research in cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Inou, T</au><au>Tomoike, H</au><au>Watanabe, K</au><au>Kikuchi, Y</au><au>Mizukami, M</au><au>Kurozumi, T</au><au>Nakamura, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis</atitle><jtitle>Basic research in cardiology</jtitle><addtitle>Basic Res Cardiol</addtitle><date>1980-07</date><risdate>1980</risdate><volume>75</volume><issue>4</issue><spage>537</spage><epage>543</epage><pages>537-543</pages><issn>0300-8428</issn><eissn>1435-1803</eissn><abstract>For the experimental studies on chronic coronary stenosis, an ameroid constrictor was modified to facilitate serial cineangiographic evaluation of the degree of arterial narrowing. A radiolucent plastic ring instead of a stainless frame was used to prevent outward swelling of the ameroid material. Coronary cineangiography was performed 10, 20 and 30 days after the implantation of the modified ameroid constrictor on the left circumflex coronary artery (LCX), which could prove the progressive coronary stenosis of 57, 78 and 88% on the respective days. Collateral channels from the anterior descending branch of the left coronary artery to the LCX were demonstrated angiographically in 5 out of the 6 dogs on the 30th day.</abstract><cop>Germany</cop><pmid>7436997</pmid><doi>10.1007/BF01907835</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0300-8428
ispartof Basic research in cardiology, 1980-07, Vol.75 (4), p.537-543
issn 0300-8428
1435-1803
language eng
recordid cdi_proquest_miscellaneous_75340789
source Springer LINK Archives
subjects Animals
Arteries - pathology
Constriction
Coronary Angiography
Coronary Disease - diagnostic imaging
Coronary Disease - etiology
Coronary Disease - pathology
Coronary Vessels - pathology
Dogs
Plastics
title A newly developed X-ray transparent ameroid constrictor for study on progression of gradual coronary stenosis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T14%3A26%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20newly%20developed%20X-ray%20transparent%20ameroid%20constrictor%20for%20study%20on%20progression%20of%20gradual%20coronary%20stenosis&rft.jtitle=Basic%20research%20in%20cardiology&rft.au=Inou,%20T&rft.date=1980-07&rft.volume=75&rft.issue=4&rft.spage=537&rft.epage=543&rft.pages=537-543&rft.issn=0300-8428&rft.eissn=1435-1803&rft_id=info:doi/10.1007/BF01907835&rft_dat=%3Cproquest_cross%3E75340789%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c282t-b5c52841df30531309b9a3b68ce7c99595e5513b7d2e1943252b5e487e7c6c493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=75340789&rft_id=info:pmid/7436997&rfr_iscdi=true