Loading…

Quantitation of polar analytes using column-switching: Application to oxycodone and three metabolites in human plasma

We present herein a sensitive and selective assay for the determination of oxycodone and its main metabolites, oxymorphone, noroxycodone and noroxymorphone in human plasma, using column-switching and liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). Sample preparation comprised p...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2010-03, Vol.878 (7), p.637-644
Main Authors: Wagner, M., Bourgogne, E., Varesio, E., Hopfgartner, G.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present herein a sensitive and selective assay for the determination of oxycodone and its main metabolites, oxymorphone, noroxycodone and noroxymorphone in human plasma, using column-switching and liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). Sample preparation comprised protein precipitation with perchloric acid. After neutralization, the supernatant was injected without any evaporation step onto a polymeric, pH-resistant cartridge (HySphere Resin GP 10–12 μm) for sample clean-up (Prospekt II). The latter operation was achieved by using alkaline conditions to ensure retention of analytes and methanol for matrix interference removal. More than two hundred plasma samples could be analyzed with a single cartridge. Analytes were desorbed in the backflush mode and were separated on a conventional reversed phase column (XTerra MS 4.6 × 50 mm, 3.5 μm), using an acidic mobile phase (i.e. containing 0.1% of formic acid). Mass spectrometric detection was achieved with a 4000 Q TRAP equipped with an atmospheric pressure chemical ionization (APCI) source, in positive ionization mode, operated in the selected reaction monitoring mode (SRM). Starting from a plasma volume of 250 μl, quantification ranges were 25–10,000 pg/ml for OXM and NOXM and 50–10,000 pg/ml for OXC and NOXC. Accuracy was found to be within 98% and 108% and precision better than 7%. Replicate determination of incurred or study samples ensured the method to be reproducible and usable for clinical studies.
ISSN:1570-0232
1873-376X
DOI:10.1016/j.jchromb.2010.01.014