Retrieval of a stripped abutment screw: A clinical report
Mechanical complications, such as loosening or damaging of the prosthetic components of an osseointegrated implant, may occur. Stripping of the implant abutment screw head can be a serious problem which can render an implant unusable. This report describes a clinical situation involving a patient wh...
Saved in:
Published in: | The Journal of prosthetic dentistry 2010-10, Vol.104 (4), p.212-215 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Mechanical complications, such as loosening or damaging of the prosthetic components of an osseointegrated implant, may occur. Stripping of the implant abutment screw head can be a serious problem which can render an implant unusable. This report describes a clinical situation involving a patient who presented with a fractured screw-retained interim crown. Upon further examination, it was determined that the abutment screw head was stripped. There was limited access and visibility in this situation since the implant was a bone-level implant. The procedure used for the removal of the stripped abutment screw head is described in detail in this clinical report. |
---|---|