Biological application of microelectrode arrays in drug discovery and basic research

Electrical activity of electrogenic cells in neuronal and cardiac tissue can be recorded by means of microelectrode arrays (MEAs) that offer the unique possibility for non-invasive extracellular recording from as many as 60 sites simultaneously. Since its introduction 30 years ago, the technology an...

Full description

Saved in:
Bibliographic Details
Published in:Analytical and bioanalytical chemistry 2003-10, Vol.377 (3), p.486-495
Main Authors: Stett, Alfred, Egert, Ulrich, Guenther, Elke, Hofmann, Frank, Meyer, Thomas, Nisch, Wilfried, Haemmerle, Hugo
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c431t-15bcc2b73575df4e2bc1207fb373c260a1c8c3d689f3ddfde0d6ece2b6717c113
cites
container_end_page 495
container_issue 3
container_start_page 486
container_title Analytical and bioanalytical chemistry
container_volume 377
creator Stett, Alfred
Egert, Ulrich
Guenther, Elke
Hofmann, Frank
Meyer, Thomas
Nisch, Wilfried
Haemmerle, Hugo
description Electrical activity of electrogenic cells in neuronal and cardiac tissue can be recorded by means of microelectrode arrays (MEAs) that offer the unique possibility for non-invasive extracellular recording from as many as 60 sites simultaneously. Since its introduction 30 years ago, the technology and the related culture methods for electrophysiological cell and tissue assays have been continually improved and have found their way into many academic and industrial laboratories. Currently, this technology is attracting increased interest owing to the industrial need to screen selected compounds against ion channel targets in their native environment at organic, cellular, and sub-cellular level. As the MEA technology can be applied to any electrogenic tissue (i.e., central and peripheral neurons, heart cells, and muscle cells), the MEA biosensor is an ideal in vitro system to monitor both acute and chronic effects of drugs and toxins and to perform functional studies under physiological or induced pathophysiological conditions that mimic in vivo damages. By recording the electrical response of various locations on a tissue, a spatial map of drug effects at different sites can be generated, providing important clues about a drug's specificity. In this survey, examples of MEA biosensor applications are described that have been developed for drug screening and discovery and safety pharmacology in the field of cardiac and neural research. Additionally, biophysical basics of recording and concepts for analysis of extracellular electrical signals are presented.
doi_str_mv 10.1007/s00216-003-2149-x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75697522</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75697522</sourcerecordid><originalsourceid>FETCH-LOGICAL-c431t-15bcc2b73575df4e2bc1207fb373c260a1c8c3d689f3ddfde0d6ece2b6717c113</originalsourceid><addsrcrecordid>eNqFkD1PwzAQhi0EolD4ASzIE1vAZ8d2MkLFl1SJpcyWYzvFKImDnaD235OqFYxMd8Pzvrp7ELoCcguEyLtECAWREcIyCnmZbY7QGQgoMio4Of7dczpD5yl9EgK8AHGKZkBLygQpztDqwYcmrL3RDdZ930zL4EOHQ41bb2JwjTNDDNZhHaPeJuw7bOO4xtYnE75d3GLdWVzp5A2OLjkdzccFOql1k9zlYc7R-9PjavGSLd-eXxf3y8zkDIYMeGUMrSTjkts6d7QyQImsKyaZoYJoMIVhVhRlzaytrSNWODNhQoI0AGyObva9fQxfo0uDaqerXNPozoUxKclFKTml_4Iw6ZCU70DYg9PrKUVXqz76VsetAqJ2ztXeuZqcq51ztZky14fysWqd_UscJLMfLcB-IQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>19237252</pqid></control><display><type>article</type><title>Biological application of microelectrode arrays in drug discovery and basic research</title><source>Springer Link</source><creator>Stett, Alfred ; Egert, Ulrich ; Guenther, Elke ; Hofmann, Frank ; Meyer, Thomas ; Nisch, Wilfried ; Haemmerle, Hugo</creator><creatorcontrib>Stett, Alfred ; Egert, Ulrich ; Guenther, Elke ; Hofmann, Frank ; Meyer, Thomas ; Nisch, Wilfried ; Haemmerle, Hugo</creatorcontrib><description>Electrical activity of electrogenic cells in neuronal and cardiac tissue can be recorded by means of microelectrode arrays (MEAs) that offer the unique possibility for non-invasive extracellular recording from as many as 60 sites simultaneously. Since its introduction 30 years ago, the technology and the related culture methods for electrophysiological cell and tissue assays have been continually improved and have found their way into many academic and industrial laboratories. Currently, this technology is attracting increased interest owing to the industrial need to screen selected compounds against ion channel targets in their native environment at organic, cellular, and sub-cellular level. As the MEA technology can be applied to any electrogenic tissue (i.e., central and peripheral neurons, heart cells, and muscle cells), the MEA biosensor is an ideal in vitro system to monitor both acute and chronic effects of drugs and toxins and to perform functional studies under physiological or induced pathophysiological conditions that mimic in vivo damages. By recording the electrical response of various locations on a tissue, a spatial map of drug effects at different sites can be generated, providing important clues about a drug's specificity. In this survey, examples of MEA biosensor applications are described that have been developed for drug screening and discovery and safety pharmacology in the field of cardiac and neural research. Additionally, biophysical basics of recording and concepts for analysis of extracellular electrical signals are presented.</description><identifier>ISSN: 1618-2642</identifier><identifier>EISSN: 1618-2650</identifier><identifier>DOI: 10.1007/s00216-003-2149-x</identifier><identifier>PMID: 12923608</identifier><language>eng</language><publisher>Germany</publisher><subject>Action Potentials - physiology ; Animals ; Biosensing Techniques - instrumentation ; Biosensing Techniques - methods ; Cells, Cultured ; Drug Evaluation, Preclinical - instrumentation ; Drug Evaluation, Preclinical - methods ; Electrophysiology ; Heart - drug effects ; Humans ; Microelectrodes ; Myocardium - cytology ; Neurons - physiology ; Organ Culture Techniques</subject><ispartof>Analytical and bioanalytical chemistry, 2003-10, Vol.377 (3), p.486-495</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c431t-15bcc2b73575df4e2bc1207fb373c260a1c8c3d689f3ddfde0d6ece2b6717c113</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12923608$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stett, Alfred</creatorcontrib><creatorcontrib>Egert, Ulrich</creatorcontrib><creatorcontrib>Guenther, Elke</creatorcontrib><creatorcontrib>Hofmann, Frank</creatorcontrib><creatorcontrib>Meyer, Thomas</creatorcontrib><creatorcontrib>Nisch, Wilfried</creatorcontrib><creatorcontrib>Haemmerle, Hugo</creatorcontrib><title>Biological application of microelectrode arrays in drug discovery and basic research</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><description>Electrical activity of electrogenic cells in neuronal and cardiac tissue can be recorded by means of microelectrode arrays (MEAs) that offer the unique possibility for non-invasive extracellular recording from as many as 60 sites simultaneously. Since its introduction 30 years ago, the technology and the related culture methods for electrophysiological cell and tissue assays have been continually improved and have found their way into many academic and industrial laboratories. Currently, this technology is attracting increased interest owing to the industrial need to screen selected compounds against ion channel targets in their native environment at organic, cellular, and sub-cellular level. As the MEA technology can be applied to any electrogenic tissue (i.e., central and peripheral neurons, heart cells, and muscle cells), the MEA biosensor is an ideal in vitro system to monitor both acute and chronic effects of drugs and toxins and to perform functional studies under physiological or induced pathophysiological conditions that mimic in vivo damages. By recording the electrical response of various locations on a tissue, a spatial map of drug effects at different sites can be generated, providing important clues about a drug's specificity. In this survey, examples of MEA biosensor applications are described that have been developed for drug screening and discovery and safety pharmacology in the field of cardiac and neural research. Additionally, biophysical basics of recording and concepts for analysis of extracellular electrical signals are presented.</description><subject>Action Potentials - physiology</subject><subject>Animals</subject><subject>Biosensing Techniques - instrumentation</subject><subject>Biosensing Techniques - methods</subject><subject>Cells, Cultured</subject><subject>Drug Evaluation, Preclinical - instrumentation</subject><subject>Drug Evaluation, Preclinical - methods</subject><subject>Electrophysiology</subject><subject>Heart - drug effects</subject><subject>Humans</subject><subject>Microelectrodes</subject><subject>Myocardium - cytology</subject><subject>Neurons - physiology</subject><subject>Organ Culture Techniques</subject><issn>1618-2642</issn><issn>1618-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2003</creationdate><recordtype>article</recordtype><recordid>eNqFkD1PwzAQhi0EolD4ASzIE1vAZ8d2MkLFl1SJpcyWYzvFKImDnaD235OqFYxMd8Pzvrp7ELoCcguEyLtECAWREcIyCnmZbY7QGQgoMio4Of7dczpD5yl9EgK8AHGKZkBLygQpztDqwYcmrL3RDdZ930zL4EOHQ41bb2JwjTNDDNZhHaPeJuw7bOO4xtYnE75d3GLdWVzp5A2OLjkdzccFOql1k9zlYc7R-9PjavGSLd-eXxf3y8zkDIYMeGUMrSTjkts6d7QyQImsKyaZoYJoMIVhVhRlzaytrSNWODNhQoI0AGyObva9fQxfo0uDaqerXNPozoUxKclFKTml_4Iw6ZCU70DYg9PrKUVXqz76VsetAqJ2ztXeuZqcq51ztZky14fysWqd_UscJLMfLcB-IQ</recordid><startdate>20031001</startdate><enddate>20031001</enddate><creator>Stett, Alfred</creator><creator>Egert, Ulrich</creator><creator>Guenther, Elke</creator><creator>Hofmann, Frank</creator><creator>Meyer, Thomas</creator><creator>Nisch, Wilfried</creator><creator>Haemmerle, Hugo</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20031001</creationdate><title>Biological application of microelectrode arrays in drug discovery and basic research</title><author>Stett, Alfred ; Egert, Ulrich ; Guenther, Elke ; Hofmann, Frank ; Meyer, Thomas ; Nisch, Wilfried ; Haemmerle, Hugo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c431t-15bcc2b73575df4e2bc1207fb373c260a1c8c3d689f3ddfde0d6ece2b6717c113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2003</creationdate><topic>Action Potentials - physiology</topic><topic>Animals</topic><topic>Biosensing Techniques - instrumentation</topic><topic>Biosensing Techniques - methods</topic><topic>Cells, Cultured</topic><topic>Drug Evaluation, Preclinical - instrumentation</topic><topic>Drug Evaluation, Preclinical - methods</topic><topic>Electrophysiology</topic><topic>Heart - drug effects</topic><topic>Humans</topic><topic>Microelectrodes</topic><topic>Myocardium - cytology</topic><topic>Neurons - physiology</topic><topic>Organ Culture Techniques</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stett, Alfred</creatorcontrib><creatorcontrib>Egert, Ulrich</creatorcontrib><creatorcontrib>Guenther, Elke</creatorcontrib><creatorcontrib>Hofmann, Frank</creatorcontrib><creatorcontrib>Meyer, Thomas</creatorcontrib><creatorcontrib>Nisch, Wilfried</creatorcontrib><creatorcontrib>Haemmerle, Hugo</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stett, Alfred</au><au>Egert, Ulrich</au><au>Guenther, Elke</au><au>Hofmann, Frank</au><au>Meyer, Thomas</au><au>Nisch, Wilfried</au><au>Haemmerle, Hugo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biological application of microelectrode arrays in drug discovery and basic research</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><addtitle>Anal Bioanal Chem</addtitle><date>2003-10-01</date><risdate>2003</risdate><volume>377</volume><issue>3</issue><spage>486</spage><epage>495</epage><pages>486-495</pages><issn>1618-2642</issn><eissn>1618-2650</eissn><abstract>Electrical activity of electrogenic cells in neuronal and cardiac tissue can be recorded by means of microelectrode arrays (MEAs) that offer the unique possibility for non-invasive extracellular recording from as many as 60 sites simultaneously. Since its introduction 30 years ago, the technology and the related culture methods for electrophysiological cell and tissue assays have been continually improved and have found their way into many academic and industrial laboratories. Currently, this technology is attracting increased interest owing to the industrial need to screen selected compounds against ion channel targets in their native environment at organic, cellular, and sub-cellular level. As the MEA technology can be applied to any electrogenic tissue (i.e., central and peripheral neurons, heart cells, and muscle cells), the MEA biosensor is an ideal in vitro system to monitor both acute and chronic effects of drugs and toxins and to perform functional studies under physiological or induced pathophysiological conditions that mimic in vivo damages. By recording the electrical response of various locations on a tissue, a spatial map of drug effects at different sites can be generated, providing important clues about a drug's specificity. In this survey, examples of MEA biosensor applications are described that have been developed for drug screening and discovery and safety pharmacology in the field of cardiac and neural research. Additionally, biophysical basics of recording and concepts for analysis of extracellular electrical signals are presented.</abstract><cop>Germany</cop><pmid>12923608</pmid><doi>10.1007/s00216-003-2149-x</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1618-2642
ispartof Analytical and bioanalytical chemistry, 2003-10, Vol.377 (3), p.486-495
issn 1618-2642
1618-2650
language eng
recordid cdi_proquest_miscellaneous_75697522
source Springer Link
subjects Action Potentials - physiology
Animals
Biosensing Techniques - instrumentation
Biosensing Techniques - methods
Cells, Cultured
Drug Evaluation, Preclinical - instrumentation
Drug Evaluation, Preclinical - methods
Electrophysiology
Heart - drug effects
Humans
Microelectrodes
Myocardium - cytology
Neurons - physiology
Organ Culture Techniques
title Biological application of microelectrode arrays in drug discovery and basic research
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T22%3A16%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biological%20application%20of%20microelectrode%20arrays%20in%20drug%20discovery%20and%20basic%20research&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=Stett,%20Alfred&rft.date=2003-10-01&rft.volume=377&rft.issue=3&rft.spage=486&rft.epage=495&rft.pages=486-495&rft.issn=1618-2642&rft.eissn=1618-2650&rft_id=info:doi/10.1007/s00216-003-2149-x&rft_dat=%3Cproquest_cross%3E75697522%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c431t-15bcc2b73575df4e2bc1207fb373c260a1c8c3d689f3ddfde0d6ece2b6717c113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=19237252&rft_id=info:pmid/12923608&rfr_iscdi=true