Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry
This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-lin...
Saved in:
Published in: | Chemosphere (Oxford) 2010-09, Vol.80 (11), p.1370-1376 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3 |
---|---|
cites | cdi_FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3 |
container_end_page | 1376 |
container_issue | 11 |
container_start_page | 1370 |
container_title | Chemosphere (Oxford) |
container_volume | 80 |
creator | Robbat, Albert Considine, Thomas Antle, Patrick M. |
description | This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140
°C temperature limit restricts analyte collection in soil to
C
2-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater. |
doi_str_mv | 10.1016/j.chemosphere.2010.06.005 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_759313945</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0045653510006521</els_id><sourcerecordid>754018875</sourcerecordid><originalsourceid>FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3</originalsourceid><addsrcrecordid>eNqNkcuO1DAQRS0EYpqBX0BhgWCTHjvxI1miFi9pJBbA2qrY5YlbSRzsBKn5ehy6eazQrCyVzi1X1SHkBaN7Rpm8Oe5Nj2NIc48R9xXNdSr3lIoHZMca1ZasapuHZEcpF6UUtbgiT1I6UprDon1MrioqWi6U2JHj57VLa3RgsLC4oFl8mIrgChdS8kPhVhyKOQzDusC0pKI7FXMflpAp_wN-wTDZ4g5SYfoYRljCXYS5P92MkFKR5twxl3GJp6fkkYMh4bPLe02-vnv75fChvP30_uPhzW1puGJLWVnnqAQA47BD10ppqeLY8JaBdMpxrFxFLVpOO14b50AA2NZV0FAlOqyvyatz3zmGbyumRY8-GRwGmDCsSSvR1qzO-9-D5JQ1jdrI1_8lmVSM8-2sGW3PqIn5hBGdnqMfIZ40o3rTp4_6H31606ep1Flfzj6_fLN2I9o_yd--MvDyAkAyMLgIk_HpL1dXrFJyG-Jw5jAf-rvHqJPxOBm0PmYj2gZ_j3F-ArWVwpo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1671442059</pqid></control><display><type>article</type><title>Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry</title><source>ScienceDirect Freedom Collection</source><creator>Robbat, Albert ; Considine, Thomas ; Antle, Patrick M.</creator><creatorcontrib>Robbat, Albert ; Considine, Thomas ; Antle, Patrick M.</creatorcontrib><description>This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140
°C temperature limit restricts analyte collection in soil to
C
2-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater.</description><identifier>ISSN: 0045-6535</identifier><identifier>EISSN: 1879-1298</identifier><identifier>DOI: 10.1016/j.chemosphere.2010.06.005</identifier><identifier>PMID: 20594575</identifier><identifier>CODEN: CMSHAF</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>Applied sciences ; Coal tar ; Coal Tar - analysis ; Crude oil ; Dense non aqueous phase liquids ; Environmental Monitoring - methods ; Exact sciences and technology ; Fossil Fuels - analysis ; Gas chromatography ; Gas Chromatography-Mass Spectrometry ; GC/MS ; Groundwater ; Hazardous waste site characterization ; Hazardous wastes ; Hydrocarbons - analysis ; In situ sampling probe ; Kinetics ; Mass spectrometry ; Photochemical Processes ; Photoionization ; Photoionization detector ; Pollutants ; Pollution ; Polytetrafluoroethylenes ; Soil Pollutants - analysis ; Subsurface ; Water Pollutants - analysis</subject><ispartof>Chemosphere (Oxford), 2010-09, Vol.80 (11), p.1370-1376</ispartof><rights>2010 Elsevier Ltd</rights><rights>2015 INIST-CNRS</rights><rights>Copyright (c) 2010 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3</citedby><cites>FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=23212769$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20594575$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Robbat, Albert</creatorcontrib><creatorcontrib>Considine, Thomas</creatorcontrib><creatorcontrib>Antle, Patrick M.</creatorcontrib><title>Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry</title><title>Chemosphere (Oxford)</title><addtitle>Chemosphere</addtitle><description>This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140
°C temperature limit restricts analyte collection in soil to
C
2-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater.</description><subject>Applied sciences</subject><subject>Coal tar</subject><subject>Coal Tar - analysis</subject><subject>Crude oil</subject><subject>Dense non aqueous phase liquids</subject><subject>Environmental Monitoring - methods</subject><subject>Exact sciences and technology</subject><subject>Fossil Fuels - analysis</subject><subject>Gas chromatography</subject><subject>Gas Chromatography-Mass Spectrometry</subject><subject>GC/MS</subject><subject>Groundwater</subject><subject>Hazardous waste site characterization</subject><subject>Hazardous wastes</subject><subject>Hydrocarbons - analysis</subject><subject>In situ sampling probe</subject><subject>Kinetics</subject><subject>Mass spectrometry</subject><subject>Photochemical Processes</subject><subject>Photoionization</subject><subject>Photoionization detector</subject><subject>Pollutants</subject><subject>Pollution</subject><subject>Polytetrafluoroethylenes</subject><subject>Soil Pollutants - analysis</subject><subject>Subsurface</subject><subject>Water Pollutants - analysis</subject><issn>0045-6535</issn><issn>1879-1298</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqNkcuO1DAQRS0EYpqBX0BhgWCTHjvxI1miFi9pJBbA2qrY5YlbSRzsBKn5ehy6eazQrCyVzi1X1SHkBaN7Rpm8Oe5Nj2NIc48R9xXNdSr3lIoHZMca1ZasapuHZEcpF6UUtbgiT1I6UprDon1MrioqWi6U2JHj57VLa3RgsLC4oFl8mIrgChdS8kPhVhyKOQzDusC0pKI7FXMflpAp_wN-wTDZ4g5SYfoYRljCXYS5P92MkFKR5twxl3GJp6fkkYMh4bPLe02-vnv75fChvP30_uPhzW1puGJLWVnnqAQA47BD10ppqeLY8JaBdMpxrFxFLVpOO14b50AA2NZV0FAlOqyvyatz3zmGbyumRY8-GRwGmDCsSSvR1qzO-9-D5JQ1jdrI1_8lmVSM8-2sGW3PqIn5hBGdnqMfIZ40o3rTp4_6H31606ep1Flfzj6_fLN2I9o_yd--MvDyAkAyMLgIk_HpL1dXrFJyG-Jw5jAf-rvHqJPxOBm0PmYj2gZ_j3F-ArWVwpo</recordid><startdate>20100901</startdate><enddate>20100901</enddate><creator>Robbat, Albert</creator><creator>Considine, Thomas</creator><creator>Antle, Patrick M.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SU</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope><scope>7X8</scope><scope>7ST</scope><scope>7TV</scope><scope>F1W</scope><scope>H95</scope><scope>H96</scope><scope>L.G</scope><scope>SOI</scope></search><sort><creationdate>20100901</creationdate><title>Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry</title><author>Robbat, Albert ; Considine, Thomas ; Antle, Patrick M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Applied sciences</topic><topic>Coal tar</topic><topic>Coal Tar - analysis</topic><topic>Crude oil</topic><topic>Dense non aqueous phase liquids</topic><topic>Environmental Monitoring - methods</topic><topic>Exact sciences and technology</topic><topic>Fossil Fuels - analysis</topic><topic>Gas chromatography</topic><topic>Gas Chromatography-Mass Spectrometry</topic><topic>GC/MS</topic><topic>Groundwater</topic><topic>Hazardous waste site characterization</topic><topic>Hazardous wastes</topic><topic>Hydrocarbons - analysis</topic><topic>In situ sampling probe</topic><topic>Kinetics</topic><topic>Mass spectrometry</topic><topic>Photochemical Processes</topic><topic>Photoionization</topic><topic>Photoionization detector</topic><topic>Pollutants</topic><topic>Pollution</topic><topic>Polytetrafluoroethylenes</topic><topic>Soil Pollutants - analysis</topic><topic>Subsurface</topic><topic>Water Pollutants - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Robbat, Albert</creatorcontrib><creatorcontrib>Considine, Thomas</creatorcontrib><creatorcontrib>Antle, Patrick M.</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Environmental Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Pollution Abstracts</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 1: Biological Sciences & Living Resources</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy & Non-Living Resources</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Environment Abstracts</collection><jtitle>Chemosphere (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Robbat, Albert</au><au>Considine, Thomas</au><au>Antle, Patrick M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry</atitle><jtitle>Chemosphere (Oxford)</jtitle><addtitle>Chemosphere</addtitle><date>2010-09-01</date><risdate>2010</risdate><volume>80</volume><issue>11</issue><spage>1370</spage><epage>1376</epage><pages>1370-1376</pages><issn>0045-6535</issn><eissn>1879-1298</eissn><coden>CMSHAF</coden><abstract>This paper describes analysis of environmental pollutants at depth without bringing sample to the surface. It is based on an improved 3-stage Peltier freeze trap, which efficiently pre-concentrates volatile coal tar and petroleum hydrocarbons, and an integrated system for detecting pollutants on-line, in real-time by photoionization detection and quantitation by gas chromatography/mass spectrometry (GC/MS) as the probe is advanced into the subsurface. Findings indicate measurement precision and accuracy for volatiles meet EPA criteria for hazardous waste site investigations. When a Teflon membrane inlet is used to detect contaminants in groundwater, its 140
°C temperature limit restricts analyte collection in soil to
C
2-phenanthrenes. Two case studies demonstrate the probe is well-suited to tracking petroleum and coal tar plumes from source to groundwater.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><pmid>20594575</pmid><doi>10.1016/j.chemosphere.2010.06.005</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0045-6535 |
ispartof | Chemosphere (Oxford), 2010-09, Vol.80 (11), p.1370-1376 |
issn | 0045-6535 1879-1298 |
language | eng |
recordid | cdi_proquest_miscellaneous_759313945 |
source | ScienceDirect Freedom Collection |
subjects | Applied sciences Coal tar Coal Tar - analysis Crude oil Dense non aqueous phase liquids Environmental Monitoring - methods Exact sciences and technology Fossil Fuels - analysis Gas chromatography Gas Chromatography-Mass Spectrometry GC/MS Groundwater Hazardous waste site characterization Hazardous wastes Hydrocarbons - analysis In situ sampling probe Kinetics Mass spectrometry Photochemical Processes Photoionization Photoionization detector Pollutants Pollution Polytetrafluoroethylenes Soil Pollutants - analysis Subsurface Water Pollutants - analysis |
title | Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T05%3A04%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Subsurface%20detection%20of%20fossil%20fuel%20pollutants%20by%20photoionization%20and%20gas%20chromatography/mass%20spectrometry&rft.jtitle=Chemosphere%20(Oxford)&rft.au=Robbat,%20Albert&rft.date=2010-09-01&rft.volume=80&rft.issue=11&rft.spage=1370&rft.epage=1376&rft.pages=1370-1376&rft.issn=0045-6535&rft.eissn=1879-1298&rft.coden=CMSHAF&rft_id=info:doi/10.1016/j.chemosphere.2010.06.005&rft_dat=%3Cproquest_cross%3E754018875%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c471t-2dff06aaacfebef966d074e8491a6f7f4e2f20ded40b43cffa5aad9f2a8075be3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1671442059&rft_id=info:pmid/20594575&rfr_iscdi=true |