Loading…

Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty

The direct manipulation of coronary blood flow to induce regional myocardial ischemia has been almost entirely limited to experimental animal models. Thus, the detection of ischemia-induced left ventricular dysfunction in human subjects has been generally limited to observations made under condition...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology 1985-02, Vol.5 (2), p.193-197
Main Authors: Hauser, Andrew M., Gangadharan, Vellappillil, Ramos, Renato G., Gordon, Seymour, Timmis, Gerald C., Dudlets, Patricia
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73
cites cdi_FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73
container_end_page 197
container_issue 2
container_start_page 193
container_title Journal of the American College of Cardiology
container_volume 5
creator Hauser, Andrew M.
Gangadharan, Vellappillil
Ramos, Renato G.
Gordon, Seymour
Timmis, Gerald C.
Dudlets, Patricia
description The direct manipulation of coronary blood flow to induce regional myocardial ischemia has been almost entirely limited to experimental animal models. Thus, the detection of ischemia-induced left ventricular dysfunction in human subjects has been generally limited to observations made under conditions of diagnostic loading or during spontaneous clinical events. Percutaneous coronary angioplasty requires repeated interruptions of coronary blood flow for periods as long as 1 minute. The resulting appearance of or increase in ischemia-produced changes in myocardial function were detected by two-dimensional echocardiography in 18 patients undergoing angioplasty of 22 coronary stenoses. Accordingly, left ventricular contraction was studied during 52 episodes of regional coronary blood flow interruption and reperfusion in the process of inflating and deflating the angioplasty balloon. Before angioplasty, left ventricular wall motion was normal in 14 patients. There was mild anteroapical hypokinesia in two patients, anteroapical akinesia in one and mild inferior hypokinesia in one. Balloon inflations repeatedly produced new or increased wall motion abnormalities in the distribution of the instrumented coronary artery in 19 (86.4%) of the 22 procedures, but did not alter wall motion during angioplasty of one left circumflex artery lesion, one highly collateralized left anterior descending artery stenosis and one left anterior descending stenosis that had already caused severe anteroapical dyssynergy. Hypokinesia, usually rapidly progressing to dyskinesia, began 19 ± 8 seconds (mean ± SD) after coronary occlusion. Wall motion began to normalize 17 ± 8 seconds after reperfusion. Electrocardiographic monitoring displayed ST segment shifts in eight procedures occurring 30 ± 5 seconds after coronary artery occlusion. These changes invariably occurred only after the onset of wall motion abnormalities and preceded or accompanied the onset of chest pain, which occurred at 39 ± 10 seconds in nine procedures. Two-dimensional echocardiography performed during coronary angioplasty provides a sensitive method for studying the myocardial mechanics of transient ischemia and reperfusion in patients. With this technique, left ventricular wall motion abnormalities are observed to invariably precede electrocardiographic changes and frequently occur without symptoms, which are the most delayed manifestation of ischemia.
doi_str_mv 10.1016/S0735-1097(85)80036-X
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_75945558</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S073510978580036X</els_id><sourcerecordid>75945558</sourcerecordid><originalsourceid>FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73</originalsourceid><addsrcrecordid>eNqFkcuKFDEUhoMoYzv6CANZiChYmnQqVanZiAzjBQZcjMLswqnkpDtSlZRJ1cA8ly9o-kIjblxlcb7z5_B_hFxw9o4z3ry_Za2QFWdd-1rJN4ox0VR3j8iKS6kqIbv2MVmdkKfkWc4_GWON4t0ZOROFaqVakd-3-GvBYJBGR0c0WwjewPCW4oBmTtFAsj5uEkxbbygES83g9whF5wqSd4sJJ4QZyzCmGCA9UEgzlicaMyzZx0B9oNtlhEB79GGTL-m12f6THvuM6R7mgmdql1S4vwLDxsdpgDw_PCdPHAwZXxzfc_Lj0_X3qy_VzbfPX68-3lRG1myuOtcrIVnPHFc9t31jseZWKcudEODkuq6FVNziWgBCJ4RsGtGDaxjU_dq14py8OuROKZaS8qxHnw0OAwSMS9at7GpZ2i6gPIAmxZwTOj0lP5arNWd6J0vvZemdCa2k3svSd2Xv4vjB0o9oT1tHO2X-8jiHXBp3CYLx-YR1bF2yRcE-HDAsZdx7TDobv3NqfSqGtI3-P4f8AYVDtvY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75945558</pqid></control><display><type>article</type><title>Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty</title><source>BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS</source><creator>Hauser, Andrew M. ; Gangadharan, Vellappillil ; Ramos, Renato G. ; Gordon, Seymour ; Timmis, Gerald C. ; Dudlets, Patricia</creator><creatorcontrib>Hauser, Andrew M. ; Gangadharan, Vellappillil ; Ramos, Renato G. ; Gordon, Seymour ; Timmis, Gerald C. ; Dudlets, Patricia</creatorcontrib><description>The direct manipulation of coronary blood flow to induce regional myocardial ischemia has been almost entirely limited to experimental animal models. Thus, the detection of ischemia-induced left ventricular dysfunction in human subjects has been generally limited to observations made under conditions of diagnostic loading or during spontaneous clinical events. Percutaneous coronary angioplasty requires repeated interruptions of coronary blood flow for periods as long as 1 minute. The resulting appearance of or increase in ischemia-produced changes in myocardial function were detected by two-dimensional echocardiography in 18 patients undergoing angioplasty of 22 coronary stenoses. Accordingly, left ventricular contraction was studied during 52 episodes of regional coronary blood flow interruption and reperfusion in the process of inflating and deflating the angioplasty balloon. Before angioplasty, left ventricular wall motion was normal in 14 patients. There was mild anteroapical hypokinesia in two patients, anteroapical akinesia in one and mild inferior hypokinesia in one. Balloon inflations repeatedly produced new or increased wall motion abnormalities in the distribution of the instrumented coronary artery in 19 (86.4%) of the 22 procedures, but did not alter wall motion during angioplasty of one left circumflex artery lesion, one highly collateralized left anterior descending artery stenosis and one left anterior descending stenosis that had already caused severe anteroapical dyssynergy. Hypokinesia, usually rapidly progressing to dyskinesia, began 19 ± 8 seconds (mean ± SD) after coronary occlusion. Wall motion began to normalize 17 ± 8 seconds after reperfusion. Electrocardiographic monitoring displayed ST segment shifts in eight procedures occurring 30 ± 5 seconds after coronary artery occlusion. These changes invariably occurred only after the onset of wall motion abnormalities and preceded or accompanied the onset of chest pain, which occurred at 39 ± 10 seconds in nine procedures. Two-dimensional echocardiography performed during coronary angioplasty provides a sensitive method for studying the myocardial mechanics of transient ischemia and reperfusion in patients. With this technique, left ventricular wall motion abnormalities are observed to invariably precede electrocardiographic changes and frequently occur without symptoms, which are the most delayed manifestation of ischemia.</description><identifier>ISSN: 0735-1097</identifier><identifier>EISSN: 1558-3597</identifier><identifier>DOI: 10.1016/S0735-1097(85)80036-X</identifier><identifier>PMID: 3155758</identifier><identifier>CODEN: JACCDI</identifier><language>eng</language><publisher>New York, NY: Elsevier Inc</publisher><subject>Adult ; Aged ; Angioplasty, Balloon ; Biological and medical sciences ; Biomechanical Phenomena ; Cardiology. Vascular system ; Coronary Circulation ; Coronary Disease - physiopathology ; Coronary Disease - therapy ; Coronary heart disease ; Echocardiography ; Electrocardiography ; Female ; Heart ; Heart Ventricles - physiopathology ; Humans ; Male ; Medical sciences ; Middle Aged ; Mitral Valve - physiopathology ; Perfusion</subject><ispartof>Journal of the American College of Cardiology, 1985-02, Vol.5 (2), p.193-197</ispartof><rights>1985 American College of Cardiology Foundation</rights><rights>1985 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73</citedby><cites>FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=9020163$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3155758$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hauser, Andrew M.</creatorcontrib><creatorcontrib>Gangadharan, Vellappillil</creatorcontrib><creatorcontrib>Ramos, Renato G.</creatorcontrib><creatorcontrib>Gordon, Seymour</creatorcontrib><creatorcontrib>Timmis, Gerald C.</creatorcontrib><creatorcontrib>Dudlets, Patricia</creatorcontrib><title>Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty</title><title>Journal of the American College of Cardiology</title><addtitle>J Am Coll Cardiol</addtitle><description>The direct manipulation of coronary blood flow to induce regional myocardial ischemia has been almost entirely limited to experimental animal models. Thus, the detection of ischemia-induced left ventricular dysfunction in human subjects has been generally limited to observations made under conditions of diagnostic loading or during spontaneous clinical events. Percutaneous coronary angioplasty requires repeated interruptions of coronary blood flow for periods as long as 1 minute. The resulting appearance of or increase in ischemia-produced changes in myocardial function were detected by two-dimensional echocardiography in 18 patients undergoing angioplasty of 22 coronary stenoses. Accordingly, left ventricular contraction was studied during 52 episodes of regional coronary blood flow interruption and reperfusion in the process of inflating and deflating the angioplasty balloon. Before angioplasty, left ventricular wall motion was normal in 14 patients. There was mild anteroapical hypokinesia in two patients, anteroapical akinesia in one and mild inferior hypokinesia in one. Balloon inflations repeatedly produced new or increased wall motion abnormalities in the distribution of the instrumented coronary artery in 19 (86.4%) of the 22 procedures, but did not alter wall motion during angioplasty of one left circumflex artery lesion, one highly collateralized left anterior descending artery stenosis and one left anterior descending stenosis that had already caused severe anteroapical dyssynergy. Hypokinesia, usually rapidly progressing to dyskinesia, began 19 ± 8 seconds (mean ± SD) after coronary occlusion. Wall motion began to normalize 17 ± 8 seconds after reperfusion. Electrocardiographic monitoring displayed ST segment shifts in eight procedures occurring 30 ± 5 seconds after coronary artery occlusion. These changes invariably occurred only after the onset of wall motion abnormalities and preceded or accompanied the onset of chest pain, which occurred at 39 ± 10 seconds in nine procedures. Two-dimensional echocardiography performed during coronary angioplasty provides a sensitive method for studying the myocardial mechanics of transient ischemia and reperfusion in patients. With this technique, left ventricular wall motion abnormalities are observed to invariably precede electrocardiographic changes and frequently occur without symptoms, which are the most delayed manifestation of ischemia.</description><subject>Adult</subject><subject>Aged</subject><subject>Angioplasty, Balloon</subject><subject>Biological and medical sciences</subject><subject>Biomechanical Phenomena</subject><subject>Cardiology. Vascular system</subject><subject>Coronary Circulation</subject><subject>Coronary Disease - physiopathology</subject><subject>Coronary Disease - therapy</subject><subject>Coronary heart disease</subject><subject>Echocardiography</subject><subject>Electrocardiography</subject><subject>Female</subject><subject>Heart</subject><subject>Heart Ventricles - physiopathology</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Mitral Valve - physiopathology</subject><subject>Perfusion</subject><issn>0735-1097</issn><issn>1558-3597</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1985</creationdate><recordtype>article</recordtype><recordid>eNqFkcuKFDEUhoMoYzv6CANZiChYmnQqVanZiAzjBQZcjMLswqnkpDtSlZRJ1cA8ly9o-kIjblxlcb7z5_B_hFxw9o4z3ry_Za2QFWdd-1rJN4ox0VR3j8iKS6kqIbv2MVmdkKfkWc4_GWON4t0ZOROFaqVakd-3-GvBYJBGR0c0WwjewPCW4oBmTtFAsj5uEkxbbygES83g9whF5wqSd4sJJ4QZyzCmGCA9UEgzlicaMyzZx0B9oNtlhEB79GGTL-m12f6THvuM6R7mgmdql1S4vwLDxsdpgDw_PCdPHAwZXxzfc_Lj0_X3qy_VzbfPX68-3lRG1myuOtcrIVnPHFc9t31jseZWKcudEODkuq6FVNziWgBCJ4RsGtGDaxjU_dq14py8OuROKZaS8qxHnw0OAwSMS9at7GpZ2i6gPIAmxZwTOj0lP5arNWd6J0vvZemdCa2k3svSd2Xv4vjB0o9oT1tHO2X-8jiHXBp3CYLx-YR1bF2yRcE-HDAsZdx7TDobv3NqfSqGtI3-P4f8AYVDtvY</recordid><startdate>198502</startdate><enddate>198502</enddate><creator>Hauser, Andrew M.</creator><creator>Gangadharan, Vellappillil</creator><creator>Ramos, Renato G.</creator><creator>Gordon, Seymour</creator><creator>Timmis, Gerald C.</creator><creator>Dudlets, Patricia</creator><general>Elsevier Inc</general><general>Elsevier Science</general><scope>6I.</scope><scope>AAFTH</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198502</creationdate><title>Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty</title><author>Hauser, Andrew M. ; Gangadharan, Vellappillil ; Ramos, Renato G. ; Gordon, Seymour ; Timmis, Gerald C. ; Dudlets, Patricia</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1985</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Angioplasty, Balloon</topic><topic>Biological and medical sciences</topic><topic>Biomechanical Phenomena</topic><topic>Cardiology. Vascular system</topic><topic>Coronary Circulation</topic><topic>Coronary Disease - physiopathology</topic><topic>Coronary Disease - therapy</topic><topic>Coronary heart disease</topic><topic>Echocardiography</topic><topic>Electrocardiography</topic><topic>Female</topic><topic>Heart</topic><topic>Heart Ventricles - physiopathology</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Mitral Valve - physiopathology</topic><topic>Perfusion</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hauser, Andrew M.</creatorcontrib><creatorcontrib>Gangadharan, Vellappillil</creatorcontrib><creatorcontrib>Ramos, Renato G.</creatorcontrib><creatorcontrib>Gordon, Seymour</creatorcontrib><creatorcontrib>Timmis, Gerald C.</creatorcontrib><creatorcontrib>Dudlets, Patricia</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the American College of Cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hauser, Andrew M.</au><au>Gangadharan, Vellappillil</au><au>Ramos, Renato G.</au><au>Gordon, Seymour</au><au>Timmis, Gerald C.</au><au>Dudlets, Patricia</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty</atitle><jtitle>Journal of the American College of Cardiology</jtitle><addtitle>J Am Coll Cardiol</addtitle><date>1985-02</date><risdate>1985</risdate><volume>5</volume><issue>2</issue><spage>193</spage><epage>197</epage><pages>193-197</pages><issn>0735-1097</issn><eissn>1558-3597</eissn><coden>JACCDI</coden><abstract>The direct manipulation of coronary blood flow to induce regional myocardial ischemia has been almost entirely limited to experimental animal models. Thus, the detection of ischemia-induced left ventricular dysfunction in human subjects has been generally limited to observations made under conditions of diagnostic loading or during spontaneous clinical events. Percutaneous coronary angioplasty requires repeated interruptions of coronary blood flow for periods as long as 1 minute. The resulting appearance of or increase in ischemia-produced changes in myocardial function were detected by two-dimensional echocardiography in 18 patients undergoing angioplasty of 22 coronary stenoses. Accordingly, left ventricular contraction was studied during 52 episodes of regional coronary blood flow interruption and reperfusion in the process of inflating and deflating the angioplasty balloon. Before angioplasty, left ventricular wall motion was normal in 14 patients. There was mild anteroapical hypokinesia in two patients, anteroapical akinesia in one and mild inferior hypokinesia in one. Balloon inflations repeatedly produced new or increased wall motion abnormalities in the distribution of the instrumented coronary artery in 19 (86.4%) of the 22 procedures, but did not alter wall motion during angioplasty of one left circumflex artery lesion, one highly collateralized left anterior descending artery stenosis and one left anterior descending stenosis that had already caused severe anteroapical dyssynergy. Hypokinesia, usually rapidly progressing to dyskinesia, began 19 ± 8 seconds (mean ± SD) after coronary occlusion. Wall motion began to normalize 17 ± 8 seconds after reperfusion. Electrocardiographic monitoring displayed ST segment shifts in eight procedures occurring 30 ± 5 seconds after coronary artery occlusion. These changes invariably occurred only after the onset of wall motion abnormalities and preceded or accompanied the onset of chest pain, which occurred at 39 ± 10 seconds in nine procedures. Two-dimensional echocardiography performed during coronary angioplasty provides a sensitive method for studying the myocardial mechanics of transient ischemia and reperfusion in patients. With this technique, left ventricular wall motion abnormalities are observed to invariably precede electrocardiographic changes and frequently occur without symptoms, which are the most delayed manifestation of ischemia.</abstract><cop>New York, NY</cop><pub>Elsevier Inc</pub><pmid>3155758</pmid><doi>10.1016/S0735-1097(85)80036-X</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0735-1097
ispartof Journal of the American College of Cardiology, 1985-02, Vol.5 (2), p.193-197
issn 0735-1097
1558-3597
language eng
recordid cdi_proquest_miscellaneous_75945558
source BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS
subjects Adult
Aged
Angioplasty, Balloon
Biological and medical sciences
Biomechanical Phenomena
Cardiology. Vascular system
Coronary Circulation
Coronary Disease - physiopathology
Coronary Disease - therapy
Coronary heart disease
Echocardiography
Electrocardiography
Female
Heart
Heart Ventricles - physiopathology
Humans
Male
Medical sciences
Middle Aged
Mitral Valve - physiopathology
Perfusion
title Sequence of mechanical, electrocardiographic and clinical effects of repeated coronary artery occlusion in human beings: Echocardiographic observations during coronary angioplasty
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T04%3A32%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sequence%20of%20mechanical,%20electrocardiographic%20and%20clinical%20effects%20of%20repeated%20coronary%20artery%20occlusion%20in%20human%20beings:%20Echocardiographic%20observations%20during%20coronary%20angioplasty&rft.jtitle=Journal%20of%20the%20American%20College%20of%20Cardiology&rft.au=Hauser,%20Andrew%20M.&rft.date=1985-02&rft.volume=5&rft.issue=2&rft.spage=193&rft.epage=197&rft.pages=193-197&rft.issn=0735-1097&rft.eissn=1558-3597&rft.coden=JACCDI&rft_id=info:doi/10.1016/S0735-1097(85)80036-X&rft_dat=%3Cproquest_cross%3E75945558%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c540t-9fb8350b0f18b1db6de41d88d1f33af52443581de23aea9335663baf60a4b2f73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=75945558&rft_id=info:pmid/3155758&rfr_iscdi=true