Loading…

Morphology and measurements of the cervical spinal cord in computer-assisted myelography

Thirty-six control subjects had computer assisted myelography (CAM) using the EMI CT 5005 scanner. The normal cervical cord is elliptical, more circular at the upper and lower ends and flatter in the mid-segments. Asymptomatic cord deformities, usually mild, were present in nine subjects (25%). Four...

Full description

Saved in:
Bibliographic Details
Published in:Neuroradiology 1985-09, Vol.27 (5), p.399-402
Main Authors: YU, Y. L, DU BOULAY, G. H, STEVENS, J. M, KENDALL, B. E
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3
cites cdi_FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3
container_end_page 402
container_issue 5
container_start_page 399
container_title Neuroradiology
container_volume 27
creator YU, Y. L
DU BOULAY, G. H
STEVENS, J. M
KENDALL, B. E
description Thirty-six control subjects had computer assisted myelography (CAM) using the EMI CT 5005 scanner. The normal cervical cord is elliptical, more circular at the upper and lower ends and flatter in the mid-segments. Asymptomatic cord deformities, usually mild, were present in nine subjects (25%). Four measurements, namely, sagittal diameter (APD), transverse diameter (TD), area (a) and circumference (c) were made and two more parameters calculated i.e. APD/TD ratio and circularity (= 4 pi a/c2). These control values form the basis of qualitative and quantitative assessment of cord deformity. When cord measurements are to be used, control values should be obtained for each scanner and procedures should be standardized.
doi_str_mv 10.1007/bf00327602
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_76438646</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>76438646</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3</originalsourceid><addsrcrecordid>eNo9kD1PwzAYhC0EKqWwsCNlQAxIATtO_DFCRQGpiAUktsh2XtOgJA52gpR_j1FLpxvuuRsehM4JviEY81ttMaYZZzg7QHOS0ywlMsOHaI5xJlIqc3yMTkL4whHjlM_QLMeF4DSbo48X5_uNa9znlKiuSlpQYfTQQjeExNlk2EBiwP_URjVJ6OsuhnG-SuouZtuPA_hUhVCHAeJ6gvjkVb-ZTtGRVU2As10u0Pvq4W35lK5fH5-Xd-vUUM6HtLAKiBQEWAGMayol4cBBF4rivJKgQGsjjWAgdVFllEkLVGlCQVpLhKELdLX97b37HiEMZVsHA02jOnBjKDnLqWA5i-D1FjTeheDBlr2vW-WnkuDyT2N5v_rXGOGL3euoW6j26M5b7C93vQrRjPWqM3XYY6KghOeC_gIPOHt7</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>76438646</pqid></control><display><type>article</type><title>Morphology and measurements of the cervical spinal cord in computer-assisted myelography</title><source>Springer Online Journal Archives (Through 1996)</source><creator>YU, Y. L ; DU BOULAY, G. H ; STEVENS, J. M ; KENDALL, B. E</creator><creatorcontrib>YU, Y. L ; DU BOULAY, G. H ; STEVENS, J. M ; KENDALL, B. E</creatorcontrib><description>Thirty-six control subjects had computer assisted myelography (CAM) using the EMI CT 5005 scanner. The normal cervical cord is elliptical, more circular at the upper and lower ends and flatter in the mid-segments. Asymptomatic cord deformities, usually mild, were present in nine subjects (25%). Four measurements, namely, sagittal diameter (APD), transverse diameter (TD), area (a) and circumference (c) were made and two more parameters calculated i.e. APD/TD ratio and circularity (= 4 pi a/c2). These control values form the basis of qualitative and quantitative assessment of cord deformity. When cord measurements are to be used, control values should be obtained for each scanner and procedures should be standardized.</description><identifier>ISSN: 0028-3940</identifier><identifier>EISSN: 1432-1920</identifier><identifier>DOI: 10.1007/bf00327602</identifier><identifier>PMID: 4058732</identifier><identifier>CODEN: NRDYAB</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Female ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Myelography ; Nervous system ; Radiodiagnosis. Nmr imagery. Nmr spectrometry ; Reference Values ; Spinal Cord - diagnostic imaging ; Tomography, X-Ray Computed</subject><ispartof>Neuroradiology, 1985-09, Vol.27 (5), p.399-402</ispartof><rights>1986 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3</citedby><cites>FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=8531748$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/4058732$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>YU, Y. L</creatorcontrib><creatorcontrib>DU BOULAY, G. H</creatorcontrib><creatorcontrib>STEVENS, J. M</creatorcontrib><creatorcontrib>KENDALL, B. E</creatorcontrib><title>Morphology and measurements of the cervical spinal cord in computer-assisted myelography</title><title>Neuroradiology</title><addtitle>Neuroradiology</addtitle><description>Thirty-six control subjects had computer assisted myelography (CAM) using the EMI CT 5005 scanner. The normal cervical cord is elliptical, more circular at the upper and lower ends and flatter in the mid-segments. Asymptomatic cord deformities, usually mild, were present in nine subjects (25%). Four measurements, namely, sagittal diameter (APD), transverse diameter (TD), area (a) and circumference (c) were made and two more parameters calculated i.e. APD/TD ratio and circularity (= 4 pi a/c2). These control values form the basis of qualitative and quantitative assessment of cord deformity. When cord measurements are to be used, control values should be obtained for each scanner and procedures should be standardized.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Female</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Myelography</subject><subject>Nervous system</subject><subject>Radiodiagnosis. Nmr imagery. Nmr spectrometry</subject><subject>Reference Values</subject><subject>Spinal Cord - diagnostic imaging</subject><subject>Tomography, X-Ray Computed</subject><issn>0028-3940</issn><issn>1432-1920</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1985</creationdate><recordtype>article</recordtype><recordid>eNo9kD1PwzAYhC0EKqWwsCNlQAxIATtO_DFCRQGpiAUktsh2XtOgJA52gpR_j1FLpxvuuRsehM4JviEY81ttMaYZZzg7QHOS0ywlMsOHaI5xJlIqc3yMTkL4whHjlM_QLMeF4DSbo48X5_uNa9znlKiuSlpQYfTQQjeExNlk2EBiwP_URjVJ6OsuhnG-SuouZtuPA_hUhVCHAeJ6gvjkVb-ZTtGRVU2As10u0Pvq4W35lK5fH5-Xd-vUUM6HtLAKiBQEWAGMayol4cBBF4rivJKgQGsjjWAgdVFllEkLVGlCQVpLhKELdLX97b37HiEMZVsHA02jOnBjKDnLqWA5i-D1FjTeheDBlr2vW-WnkuDyT2N5v_rXGOGL3euoW6j26M5b7C93vQrRjPWqM3XYY6KghOeC_gIPOHt7</recordid><startdate>198509</startdate><enddate>198509</enddate><creator>YU, Y. L</creator><creator>DU BOULAY, G. H</creator><creator>STEVENS, J. M</creator><creator>KENDALL, B. E</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198509</creationdate><title>Morphology and measurements of the cervical spinal cord in computer-assisted myelography</title><author>YU, Y. L ; DU BOULAY, G. H ; STEVENS, J. M ; KENDALL, B. E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1985</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Female</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Myelography</topic><topic>Nervous system</topic><topic>Radiodiagnosis. Nmr imagery. Nmr spectrometry</topic><topic>Reference Values</topic><topic>Spinal Cord - diagnostic imaging</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>YU, Y. L</creatorcontrib><creatorcontrib>DU BOULAY, G. H</creatorcontrib><creatorcontrib>STEVENS, J. M</creatorcontrib><creatorcontrib>KENDALL, B. E</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Neuroradiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>YU, Y. L</au><au>DU BOULAY, G. H</au><au>STEVENS, J. M</au><au>KENDALL, B. E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Morphology and measurements of the cervical spinal cord in computer-assisted myelography</atitle><jtitle>Neuroradiology</jtitle><addtitle>Neuroradiology</addtitle><date>1985-09</date><risdate>1985</risdate><volume>27</volume><issue>5</issue><spage>399</spage><epage>402</epage><pages>399-402</pages><issn>0028-3940</issn><eissn>1432-1920</eissn><coden>NRDYAB</coden><abstract>Thirty-six control subjects had computer assisted myelography (CAM) using the EMI CT 5005 scanner. The normal cervical cord is elliptical, more circular at the upper and lower ends and flatter in the mid-segments. Asymptomatic cord deformities, usually mild, were present in nine subjects (25%). Four measurements, namely, sagittal diameter (APD), transverse diameter (TD), area (a) and circumference (c) were made and two more parameters calculated i.e. APD/TD ratio and circularity (= 4 pi a/c2). These control values form the basis of qualitative and quantitative assessment of cord deformity. When cord measurements are to be used, control values should be obtained for each scanner and procedures should be standardized.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>4058732</pmid><doi>10.1007/bf00327602</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0028-3940
ispartof Neuroradiology, 1985-09, Vol.27 (5), p.399-402
issn 0028-3940
1432-1920
language eng
recordid cdi_proquest_miscellaneous_76438646
source Springer Online Journal Archives (Through 1996)
subjects Adult
Aged
Biological and medical sciences
Female
Humans
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Middle Aged
Myelography
Nervous system
Radiodiagnosis. Nmr imagery. Nmr spectrometry
Reference Values
Spinal Cord - diagnostic imaging
Tomography, X-Ray Computed
title Morphology and measurements of the cervical spinal cord in computer-assisted myelography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T09%3A24%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Morphology%20and%20measurements%20of%20the%20cervical%20spinal%20cord%20in%20computer-assisted%20myelography&rft.jtitle=Neuroradiology&rft.au=YU,%20Y.%20L&rft.date=1985-09&rft.volume=27&rft.issue=5&rft.spage=399&rft.epage=402&rft.pages=399-402&rft.issn=0028-3940&rft.eissn=1432-1920&rft.coden=NRDYAB&rft_id=info:doi/10.1007/bf00327602&rft_dat=%3Cproquest_cross%3E76438646%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c377t-5fae1981e65e67b39917e7eb5a304d9eaebbc9c86e9b5d2369fe3ab13e9ff18c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=76438646&rft_id=info:pmid/4058732&rfr_iscdi=true