Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications

A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB...

Full description

Saved in:
Bibliographic Details
Published in:Analytical biochemistry 1995, Vol.224 (1), p.212-220
Main Authors: Yun, J.H., Meyerhoff, M.E., Yang, V.C.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c339t-fcb8ec8d28e10b86752729c2b32296fe1bf19719caafe407ebfb9f1650a58e193
cites
container_end_page 220
container_issue 1
container_start_page 212
container_title Analytical biochemistry
container_volume 224
creator Yun, J.H.
Meyerhoff, M.E.
Yang, V.C.
description A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB) (at 1 wt%), within a specially formulated polymer membrane composed of 33 wt% 2-nitrophenyl octyl ether (2-NPOE), and 66 wt% poly(vinyl chloride) (PVC). When the polymer film is mounted in an appropriate electrode body, the resulting membrane electrode responds reproducibly to protamine via a nonequilibrium quasi-steady-state change in the phase boundary potential at the membrane/sample interface. Such response can be used to directly monitor, via classical potentiometric titrations, the binding between protamine and a variety of native (porcine and beef) as well as low-molecular-weight heparins. Scatchard analysis of the EMF titration data provides binding constants and stoichiometries for protamine-heparin interactions. The electrode can be further used to follow the enzymatic digestion of protamine by trypsin. In the presence of a given level of protamine, initial rates of potential decrease (− dE/ dt) are shown to be linearly related to trypsin activity in solution over the range of 0-130 units/ml. The speed and simplicity of the protamine sensor make it an attractive alternative to classical methods for studying the interaction of protamine with other biologically important macromolecules as well as the proteolytic activity and reaction kinetics of trypsin.
doi_str_mv 10.1006/abio.1995.1032
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77210451</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003269785710329</els_id><sourcerecordid>77210451</sourcerecordid><originalsourceid>FETCH-LOGICAL-c339t-fcb8ec8d28e10b86752729c2b32296fe1bf19719caafe407ebfb9f1650a58e193</originalsourceid><addsrcrecordid>eNp1kM9LwzAUx4Moc06v3oSevHUm6Y803nTMHzBxoJ5Dkr5gpG1q0g3mX2_KhjdPL4_vD14-CF0SPCcYlzdSWTcnnBdxzegRmhLMyxRnmB-jKcY4S2nJ2Sk6C-ELY0LyopygCWMxzPIpEmvvBtnaDtI36IId7BaStWt2LfjkBVrlZQfJsgE9eFfDbbL4lF7qAbz9kYN1XSK7Orm3Tnay2Q1Wyya56_smPkY1nKMTI5sAF4c5Qx8Py_fFU7p6fXxe3K1SnWV8SI1WFeiqphUQrKqSFZRRrqnKKOWlAaIM4YxwLaWBHDNQRnFDygLLIkZ4NkPX-97eu-8NhEG0Nmhomni-2wTBGCU4L0g0zvdG7V0IHozovW2l3wmCxUhUjETFSFSMRGPg6tC8US3Uf_YDwqhXex3i97YWvAjaQqehtj5SE7Wz_1X_AgNdhr0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77210451</pqid></control><display><type>article</type><title>Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications</title><source>ScienceDirect Freedom Collection</source><creator>Yun, J.H. ; Meyerhoff, M.E. ; Yang, V.C.</creator><creatorcontrib>Yun, J.H. ; Meyerhoff, M.E. ; Yang, V.C.</creatorcontrib><description>A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB) (at 1 wt%), within a specially formulated polymer membrane composed of 33 wt% 2-nitrophenyl octyl ether (2-NPOE), and 66 wt% poly(vinyl chloride) (PVC). When the polymer film is mounted in an appropriate electrode body, the resulting membrane electrode responds reproducibly to protamine via a nonequilibrium quasi-steady-state change in the phase boundary potential at the membrane/sample interface. Such response can be used to directly monitor, via classical potentiometric titrations, the binding between protamine and a variety of native (porcine and beef) as well as low-molecular-weight heparins. Scatchard analysis of the EMF titration data provides binding constants and stoichiometries for protamine-heparin interactions. The electrode can be further used to follow the enzymatic digestion of protamine by trypsin. In the presence of a given level of protamine, initial rates of potential decrease (− dE/ dt) are shown to be linearly related to trypsin activity in solution over the range of 0-130 units/ml. The speed and simplicity of the protamine sensor make it an attractive alternative to classical methods for studying the interaction of protamine with other biologically important macromolecules as well as the proteolytic activity and reaction kinetics of trypsin.</description><identifier>ISSN: 0003-2697</identifier><identifier>EISSN: 1096-0309</identifier><identifier>DOI: 10.1006/abio.1995.1032</identifier><identifier>PMID: 7710074</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Electrodes ; Heparin - analysis ; Membranes, Artificial ; Potentiometry ; Protamines - pharmacology ; Trypsin - metabolism</subject><ispartof>Analytical biochemistry, 1995, Vol.224 (1), p.212-220</ispartof><rights>1995 Academic Press</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c339t-fcb8ec8d28e10b86752729c2b32296fe1bf19719caafe407ebfb9f1650a58e193</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7710074$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yun, J.H.</creatorcontrib><creatorcontrib>Meyerhoff, M.E.</creatorcontrib><creatorcontrib>Yang, V.C.</creatorcontrib><title>Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications</title><title>Analytical biochemistry</title><addtitle>Anal Biochem</addtitle><description>A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB) (at 1 wt%), within a specially formulated polymer membrane composed of 33 wt% 2-nitrophenyl octyl ether (2-NPOE), and 66 wt% poly(vinyl chloride) (PVC). When the polymer film is mounted in an appropriate electrode body, the resulting membrane electrode responds reproducibly to protamine via a nonequilibrium quasi-steady-state change in the phase boundary potential at the membrane/sample interface. Such response can be used to directly monitor, via classical potentiometric titrations, the binding between protamine and a variety of native (porcine and beef) as well as low-molecular-weight heparins. Scatchard analysis of the EMF titration data provides binding constants and stoichiometries for protamine-heparin interactions. The electrode can be further used to follow the enzymatic digestion of protamine by trypsin. In the presence of a given level of protamine, initial rates of potential decrease (− dE/ dt) are shown to be linearly related to trypsin activity in solution over the range of 0-130 units/ml. The speed and simplicity of the protamine sensor make it an attractive alternative to classical methods for studying the interaction of protamine with other biologically important macromolecules as well as the proteolytic activity and reaction kinetics of trypsin.</description><subject>Electrodes</subject><subject>Heparin - analysis</subject><subject>Membranes, Artificial</subject><subject>Potentiometry</subject><subject>Protamines - pharmacology</subject><subject>Trypsin - metabolism</subject><issn>0003-2697</issn><issn>1096-0309</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNp1kM9LwzAUx4Moc06v3oSevHUm6Y803nTMHzBxoJ5Dkr5gpG1q0g3mX2_KhjdPL4_vD14-CF0SPCcYlzdSWTcnnBdxzegRmhLMyxRnmB-jKcY4S2nJ2Sk6C-ELY0LyopygCWMxzPIpEmvvBtnaDtI36IId7BaStWt2LfjkBVrlZQfJsgE9eFfDbbL4lF7qAbz9kYN1XSK7Orm3Tnay2Q1Wyya56_smPkY1nKMTI5sAF4c5Qx8Py_fFU7p6fXxe3K1SnWV8SI1WFeiqphUQrKqSFZRRrqnKKOWlAaIM4YxwLaWBHDNQRnFDygLLIkZ4NkPX-97eu-8NhEG0Nmhomni-2wTBGCU4L0g0zvdG7V0IHozovW2l3wmCxUhUjETFSFSMRGPg6tC8US3Uf_YDwqhXex3i97YWvAjaQqehtj5SE7Wz_1X_AgNdhr0</recordid><startdate>1995</startdate><enddate>1995</enddate><creator>Yun, J.H.</creator><creator>Meyerhoff, M.E.</creator><creator>Yang, V.C.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1995</creationdate><title>Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications</title><author>Yun, J.H. ; Meyerhoff, M.E. ; Yang, V.C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c339t-fcb8ec8d28e10b86752729c2b32296fe1bf19719caafe407ebfb9f1650a58e193</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Electrodes</topic><topic>Heparin - analysis</topic><topic>Membranes, Artificial</topic><topic>Potentiometry</topic><topic>Protamines - pharmacology</topic><topic>Trypsin - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yun, J.H.</creatorcontrib><creatorcontrib>Meyerhoff, M.E.</creatorcontrib><creatorcontrib>Yang, V.C.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical biochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yun, J.H.</au><au>Meyerhoff, M.E.</au><au>Yang, V.C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications</atitle><jtitle>Analytical biochemistry</jtitle><addtitle>Anal Biochem</addtitle><date>1995</date><risdate>1995</risdate><volume>224</volume><issue>1</issue><spage>212</spage><epage>220</epage><pages>212-220</pages><issn>0003-2697</issn><eissn>1096-0309</eissn><abstract>A polymeric membrane electrode that exhibits significant and analytically useful potentiometric response to submicromolar levels of the heparin antagonist, protamine, is reported. The sensor is prepared by incorporating a lipophilic cation exchanger, potassium tetrakis(4-chlorophenyl)borate (KTpClPB) (at 1 wt%), within a specially formulated polymer membrane composed of 33 wt% 2-nitrophenyl octyl ether (2-NPOE), and 66 wt% poly(vinyl chloride) (PVC). When the polymer film is mounted in an appropriate electrode body, the resulting membrane electrode responds reproducibly to protamine via a nonequilibrium quasi-steady-state change in the phase boundary potential at the membrane/sample interface. Such response can be used to directly monitor, via classical potentiometric titrations, the binding between protamine and a variety of native (porcine and beef) as well as low-molecular-weight heparins. Scatchard analysis of the EMF titration data provides binding constants and stoichiometries for protamine-heparin interactions. The electrode can be further used to follow the enzymatic digestion of protamine by trypsin. In the presence of a given level of protamine, initial rates of potential decrease (− dE/ dt) are shown to be linearly related to trypsin activity in solution over the range of 0-130 units/ml. The speed and simplicity of the protamine sensor make it an attractive alternative to classical methods for studying the interaction of protamine with other biologically important macromolecules as well as the proteolytic activity and reaction kinetics of trypsin.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>7710074</pmid><doi>10.1006/abio.1995.1032</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2697
ispartof Analytical biochemistry, 1995, Vol.224 (1), p.212-220
issn 0003-2697
1096-0309
language eng
recordid cdi_proquest_miscellaneous_77210451
source ScienceDirect Freedom Collection
subjects Electrodes
Heparin - analysis
Membranes, Artificial
Potentiometry
Protamines - pharmacology
Trypsin - metabolism
title Protamine-Sensitive Polymer Membrane Electrode: Characterization and Bioanalytical Applications
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T08%3A25%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Protamine-Sensitive%20Polymer%20Membrane%20Electrode:%20Characterization%20and%20Bioanalytical%20Applications&rft.jtitle=Analytical%20biochemistry&rft.au=Yun,%20J.H.&rft.date=1995&rft.volume=224&rft.issue=1&rft.spage=212&rft.epage=220&rft.pages=212-220&rft.issn=0003-2697&rft.eissn=1096-0309&rft_id=info:doi/10.1006/abio.1995.1032&rft_dat=%3Cproquest_cross%3E77210451%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c339t-fcb8ec8d28e10b86752729c2b32296fe1bf19719caafe407ebfb9f1650a58e193%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=77210451&rft_id=info:pmid/7710074&rfr_iscdi=true