Estimation of arterial PCO2 during high frequency jet ventilation: studies in the dog
The arterial to end-tidal PCO2 difference (PaCO2-PE'CO2) was measured in five anaesthetized dogs during controlled ventilation at 0.25 Hz (15 b.p.m.) and during high frequency jet ventilation at 1, 3 and 5 Hz. Because of the slow response of the infra-red carbon dioxide analyser, satisfactory r...
Saved in:
Published in: | British journal of anaesthesia : BJA 1987-02, Vol.59 (2), p.240-246 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The arterial to end-tidal PCO2 difference (PaCO2-PE'CO2) was measured in five anaesthetized dogs during controlled ventilation at 0.25 Hz (15 b.p.m.) and during high frequency jet ventilation at 1, 3 and 5 Hz. Because of the slow response of the infra-red carbon dioxide analyser, satisfactory recordings of end-tidal carbon dioxide could not be obtained at frequencies greater than 1 Hz. The interruption of high frequency jet ventilation by conventional ventilation resulted in approximately equal arterial and end-tidal PCO2 values during the first breath, and restoration of the normal arterial to end-tidal PCO2 difference by the third breath. It is concluded that, when high frequency jet ventilation at 1, 3 or 5 Hz is interrupted with normal tidal volumes at low frequencies, the arterial PCO2 can be estimated from recordings of the end-tidal PCO2. |
---|---|