Loading…
Storage-phosphor autoradiography: A rapid and highly sensitive method for spatial imaging and quantitation of radioisotopes
This study evaluates a storage-phosphor imaging system for rapid autoradiography and quantitation of β- and γ-ray emitters in mice. Known quantities of authentic 3H, 14C, and 195mPt (0.06 to 31,714 DPM/mm 2) were exposed to imaging plates of the storage-phosphor system for 0.5 min to 15 hr at room t...
Saved in:
Published in: | Journal of pharmacological and toxicological methods 1995-06, Vol.33 (3), p.171-178 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study evaluates a storage-phosphor imaging system for rapid autoradiography and quantitation of β- and γ-ray emitters in mice. Known quantities of authentic
3H,
14C, and
195mPt (0.06 to 31,714 DPM/mm
2) were exposed to imaging plates of the storage-phosphor system for 0.5 min to 15 hr at room temperature. Immediately after exposure, the imaging plates were scanned and the autoradiograms were quantified. Radioactivity as low as 1.8 DPM/mm
2 (
3H), 0.06 DPM/mm
2 (
14C) and 3.1 DPM/mm
2 (
195mPt) was visualized and quantified in 8 hr (
3H and
14C) and 6 min (
195mPt), respectively. The system displayed a linear range of four to five orders of magnitude (
14C: 0.5 to 6,914 DPM/mm
2 for 2-hr exposure;
3H: 1.8 to 15,372 DPM/mm
2 for 15-hr exposure; and
195mPt: 66 to 198,000 DPM 6 min-exposure). Variation from scan-to-scan was small (< 1% to 5%) and was more pronounced at the lower detection limits and exposure periods. Similar sensitivity, linearity, and variability were obtained in cryosections of murine tumors treated with
14C-fluorouracil or
3H-epinephrine and whole-body autoradiograms of mice treated with
195mPt-cisplatin via liver. The high sensitivity allowed noninvasive imaging of live unanesthetized mice treated with
195mPt with a short exposure time (105 sec). These results validate, for the first time, the high sensitivity, linearity, and wide dynamic range of storage-phosphor technology for quantitative autoradiography of
14C,
3H, and
195mPt isotopes. Storage-phosphor imaging will be useful in rapid quantitative autoradiographic disposition studies of radiolabeled drugs and excipients
in vitro and
in vivo. |
---|---|
ISSN: | 1056-8719 1873-488X |
DOI: | 10.1016/1056-8719(94)00089-M |