Loading…

Radiographic calculation of anteversion in acetabular prostheses

The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Antero...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of arthroplasty 1995-06, Vol.10 (3), p.369-372
Main Authors: Hassan, Douglas M., Johnston, Geoffrey H.F., Dust, William N.C., Watson, L. Glen, Cassidy, David
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3
cites cdi_FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3
container_end_page 372
container_issue 3
container_start_page 369
container_title The Journal of arthroplasty
container_volume 10
creator Hassan, Douglas M.
Johnston, Geoffrey H.F.
Dust, William N.C.
Watson, L. Glen
Cassidy, David
description The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Anteroposterior radiographs were taken with the cup in five different positions of anteversion. These were reviewed by five orthopaedic surgeons, and measurements were taken from each radiograph. From these measurements, the mathematically derived degree of version was calculated. The results were examined for accuracy and intraobserver reliability. It was concluded that intraobserver reliability was very good and that the accuracy was within a clinically acceptable range. This technique could be useful in studying the “safe zone” for acetabular prostheses.
doi_str_mv 10.1016/S0883-5403(05)80187-1
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77518280</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0883540305801871</els_id><sourcerecordid>77518280</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3</originalsourceid><addsrcrecordid>eNqFkElLxEAQhRtRxnH0JwzkJHqI9prunFQGNxgQXM5NLxWnJZOM3cmA_97MgldPRfFe1av6EJoSfEUwKa7fsFIsFxyzCywuFSZK5uQAjYlgNFccF4do_Gc5RicpfWFMiBB8hEaykKwkcoxuX40P7Wc0q0VwmTO162vThbbJ2iozTQdriGnThiYzDjpjBz1mq9imbgEJ0ik6qkyd4GxfJ-jj4f599pTPXx6fZ3fz3HFCu5wXFShsCiaowBwsFV4RSbxktuLS-pJaWnIjvSqJLxXIonTWMc8ppt5bwybofLd3iP7uIXV6GZKDujYNtH3SUgqiqMKDUeyMbrgxRaj0KoaliT-aYL0hp7fk9AaLxkJvyWkyzE33Ab1dgv-b2qMa9JudDsOX6wBRJxegceBDBNdp34Z_En4BJqt95A</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77518280</pqid></control><display><type>article</type><title>Radiographic calculation of anteversion in acetabular prostheses</title><source>ScienceDirect Journals</source><creator>Hassan, Douglas M. ; Johnston, Geoffrey H.F. ; Dust, William N.C. ; Watson, L. Glen ; Cassidy, David</creator><creatorcontrib>Hassan, Douglas M. ; Johnston, Geoffrey H.F. ; Dust, William N.C. ; Watson, L. Glen ; Cassidy, David</creatorcontrib><description>The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Anteroposterior radiographs were taken with the cup in five different positions of anteversion. These were reviewed by five orthopaedic surgeons, and measurements were taken from each radiograph. From these measurements, the mathematically derived degree of version was calculated. The results were examined for accuracy and intraobserver reliability. It was concluded that intraobserver reliability was very good and that the accuracy was within a clinically acceptable range. This technique could be useful in studying the “safe zone” for acetabular prostheses.</description><identifier>ISSN: 0883-5403</identifier><identifier>EISSN: 1532-8406</identifier><identifier>DOI: 10.1016/S0883-5403(05)80187-1</identifier><identifier>PMID: 7673917</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>acetabular anteversion ; acetabular prosthesis ; Acetabulum - anatomy &amp; histology ; Acetabulum - diagnostic imaging ; dislocation ; hip arthroplasty ; Hip Prosthesis ; Humans ; Models, Theoretical ; Observer Variation ; radiographic calculation ; Radiography</subject><ispartof>The Journal of arthroplasty, 1995-06, Vol.10 (3), p.369-372</ispartof><rights>1995 Churchill Livingstone Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3</citedby><cites>FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7673917$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hassan, Douglas M.</creatorcontrib><creatorcontrib>Johnston, Geoffrey H.F.</creatorcontrib><creatorcontrib>Dust, William N.C.</creatorcontrib><creatorcontrib>Watson, L. Glen</creatorcontrib><creatorcontrib>Cassidy, David</creatorcontrib><title>Radiographic calculation of anteversion in acetabular prostheses</title><title>The Journal of arthroplasty</title><addtitle>J Arthroplasty</addtitle><description>The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Anteroposterior radiographs were taken with the cup in five different positions of anteversion. These were reviewed by five orthopaedic surgeons, and measurements were taken from each radiograph. From these measurements, the mathematically derived degree of version was calculated. The results were examined for accuracy and intraobserver reliability. It was concluded that intraobserver reliability was very good and that the accuracy was within a clinically acceptable range. This technique could be useful in studying the “safe zone” for acetabular prostheses.</description><subject>acetabular anteversion</subject><subject>acetabular prosthesis</subject><subject>Acetabulum - anatomy &amp; histology</subject><subject>Acetabulum - diagnostic imaging</subject><subject>dislocation</subject><subject>hip arthroplasty</subject><subject>Hip Prosthesis</subject><subject>Humans</subject><subject>Models, Theoretical</subject><subject>Observer Variation</subject><subject>radiographic calculation</subject><subject>Radiography</subject><issn>0883-5403</issn><issn>1532-8406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><recordid>eNqFkElLxEAQhRtRxnH0JwzkJHqI9prunFQGNxgQXM5NLxWnJZOM3cmA_97MgldPRfFe1av6EJoSfEUwKa7fsFIsFxyzCywuFSZK5uQAjYlgNFccF4do_Gc5RicpfWFMiBB8hEaykKwkcoxuX40P7Wc0q0VwmTO162vThbbJ2iozTQdriGnThiYzDjpjBz1mq9imbgEJ0ik6qkyd4GxfJ-jj4f599pTPXx6fZ3fz3HFCu5wXFShsCiaowBwsFV4RSbxktuLS-pJaWnIjvSqJLxXIonTWMc8ppt5bwybofLd3iP7uIXV6GZKDujYNtH3SUgqiqMKDUeyMbrgxRaj0KoaliT-aYL0hp7fk9AaLxkJvyWkyzE33Ab1dgv-b2qMa9JudDsOX6wBRJxegceBDBNdp34Z_En4BJqt95A</recordid><startdate>19950601</startdate><enddate>19950601</enddate><creator>Hassan, Douglas M.</creator><creator>Johnston, Geoffrey H.F.</creator><creator>Dust, William N.C.</creator><creator>Watson, L. Glen</creator><creator>Cassidy, David</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19950601</creationdate><title>Radiographic calculation of anteversion in acetabular prostheses</title><author>Hassan, Douglas M. ; Johnston, Geoffrey H.F. ; Dust, William N.C. ; Watson, L. Glen ; Cassidy, David</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>acetabular anteversion</topic><topic>acetabular prosthesis</topic><topic>Acetabulum - anatomy &amp; histology</topic><topic>Acetabulum - diagnostic imaging</topic><topic>dislocation</topic><topic>hip arthroplasty</topic><topic>Hip Prosthesis</topic><topic>Humans</topic><topic>Models, Theoretical</topic><topic>Observer Variation</topic><topic>radiographic calculation</topic><topic>Radiography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hassan, Douglas M.</creatorcontrib><creatorcontrib>Johnston, Geoffrey H.F.</creatorcontrib><creatorcontrib>Dust, William N.C.</creatorcontrib><creatorcontrib>Watson, L. Glen</creatorcontrib><creatorcontrib>Cassidy, David</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>The Journal of arthroplasty</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hassan, Douglas M.</au><au>Johnston, Geoffrey H.F.</au><au>Dust, William N.C.</au><au>Watson, L. Glen</au><au>Cassidy, David</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Radiographic calculation of anteversion in acetabular prostheses</atitle><jtitle>The Journal of arthroplasty</jtitle><addtitle>J Arthroplasty</addtitle><date>1995-06-01</date><risdate>1995</risdate><volume>10</volume><issue>3</issue><spage>369</spage><epage>372</epage><pages>369-372</pages><issn>0883-5403</issn><eissn>1532-8406</eissn><abstract>The position of the acetabular prosthesis is critical for preventing dislocation following total hip arthroplasty. The reliability of a mathematical model for radiographically calculated acetabular cup version was examined. A porous-coated anatomic acetabular prosthesis was mounted in a mold. Anteroposterior radiographs were taken with the cup in five different positions of anteversion. These were reviewed by five orthopaedic surgeons, and measurements were taken from each radiograph. From these measurements, the mathematically derived degree of version was calculated. The results were examined for accuracy and intraobserver reliability. It was concluded that intraobserver reliability was very good and that the accuracy was within a clinically acceptable range. This technique could be useful in studying the “safe zone” for acetabular prostheses.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>7673917</pmid><doi>10.1016/S0883-5403(05)80187-1</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-5403
ispartof The Journal of arthroplasty, 1995-06, Vol.10 (3), p.369-372
issn 0883-5403
1532-8406
language eng
recordid cdi_proquest_miscellaneous_77518280
source ScienceDirect Journals
subjects acetabular anteversion
acetabular prosthesis
Acetabulum - anatomy & histology
Acetabulum - diagnostic imaging
dislocation
hip arthroplasty
Hip Prosthesis
Humans
Models, Theoretical
Observer Variation
radiographic calculation
Radiography
title Radiographic calculation of anteversion in acetabular prostheses
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T07%3A15%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Radiographic%20calculation%20of%20anteversion%20in%20acetabular%20prostheses&rft.jtitle=The%20Journal%20of%20arthroplasty&rft.au=Hassan,%20Douglas%20M.&rft.date=1995-06-01&rft.volume=10&rft.issue=3&rft.spage=369&rft.epage=372&rft.pages=369-372&rft.issn=0883-5403&rft.eissn=1532-8406&rft_id=info:doi/10.1016/S0883-5403(05)80187-1&rft_dat=%3Cproquest_cross%3E77518280%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c412t-46fe80a6352504eb25d8171d73bf47bd92b294a7d891d98e769cbc3d4202ddba3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=77518280&rft_id=info:pmid/7673917&rfr_iscdi=true