A high efficiency method for purification and assay of bee venom phospholipase A2

Phosphotipase A2 (PLA2) is the main allergen of hymenopteran venoms, We describe a highly efficient reverse phase high performance liquid chromatographic method (HPLC) for isolating PLA2 from crude bee venom. This method removes all detectable contaminants such as melittin from PLA2 while preserving...

Full description

Saved in:
Bibliographic Details
Published in:Pathology 1995, Vol.27 (2), p.157-160
Main Authors: Ameratunga, R.V., Hawkins, R., Prestidge, R., Marbrook, J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Phosphotipase A2 (PLA2) is the main allergen of hymenopteran venoms, We describe a highly efficient reverse phase high performance liquid chromatographic method (HPLC) for isolating PLA2 from crude bee venom. This method removes all detectable contaminants such as melittin from PLA2 while preserving the hemolytic action of PLA2. In addition we describe a simple functional assay of PLA2 based on its propensity to cause hemolysis of guina pig red blood cells. These techniques are particularly well suited to the isolation and assessment of PLA2 of venoms which are available in limited quantities.
ISSN:0031-3025
1465-3931
DOI:10.1080/00313029500169782