Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience

To assess the long‐term capability of single atrioven ticular (AV) lead VDD pacing systems using close atrial dipoles to assure reliable atrial guided pacing, the safety and efficacy of 86 VDD units implanted in 73 patients at a single center since November 1988 was reviewed. All patients suffered f...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 1994-11, Vol.17 (11), p.1865-1869
Main Authors: ANSANI, LUCIA, PERCOCO, GIAN FRANCO, GUARDIGLI, GABRIELE, TOSELLI, TIZIANO, ANTONIOLI, GIAN ENRICO
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3
cites cdi_FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3
container_end_page 1869
container_issue 11
container_start_page 1865
container_title Pacing and clinical electrophysiology
container_volume 17
creator ANSANI, LUCIA
PERCOCO, GIAN FRANCO
GUARDIGLI, GABRIELE
TOSELLI, TIZIANO
ANTONIOLI, GIAN ENRICO
description To assess the long‐term capability of single atrioven ticular (AV) lead VDD pacing systems using close atrial dipoles to assure reliable atrial guided pacing, the safety and efficacy of 86 VDD units implanted in 73 patients at a single center since November 1988 was reviewed. All patients suffered from advanced AV block with normal sinoatrial function. Sixty five patients received a LEM/CCS Twinal 30/30S system, four patients received a Vitatron‐Saphir system, and four patients received a Medtronic Thera VDR 8348 system. All patients underwent provocative tests in search of myopotential interference, and Holter recordings; in a group of patients who underwent pacemaker replacement a comparison was made between implant and replacement measurements. The mean follow‐up duration was 27.3 months. A high percentage of successfully VDD paced patients and a low incidence of pacemaker malfunction, regularly solved by pacemaker reprogramming, was reported. Atrial signal amplitudes comparable to those measured at implant were found at replacement in all patients. These data support the long‐term reliability of single AV lead VDD pacing systems with closely spaced atrial dipoles, as well as stable atrial sensing by floating bipolar atrial electrodes and effective atrial synchronous ventricular pacing over time.
doi_str_mv 10.1111/j.1540-8159.1994.tb03764.x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77712073</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77712073</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3</originalsourceid><addsrcrecordid>eNqVkE1v0zAYxy0EGmXwEZAsDtyS2XEcJztRdd2GFI2xliFOluM-GS7OC3YKzW0fHUetescXy_6_PHp-CH2gJKbhXGxjylMS5ZQXMS2KNB4qwkSWxvsXaHaSXqIZoamIcpYXr9Eb77eEkIyk_AydiTzlIk9m6Lns2qdoDa7BD2CNqow1w4i7Gq9M-2QBl6A2eD44oyxeja3-6bq223l8r3QwhC8_QOPxNz-9FrbzYEe86pWGU-zK9J0Ff4mvzR-IfoByeLnvwRloNbxFr2plPbw73udofb1cL26j8svN58W8jDTjjEdCZ1mlE8GTsI7KE8UEqWnFk03FK6G1UpwpnqSJToucqkowSvSmAi4UL2jNztHHQ23vut878INsjNdgrWohrCOFEDQhggXj5cGoXee9g1r2zjTKjZISOdGXWzkhlhNiOdGXR_pyH8Lvj1N2VQObU_SIO-ifDvpfY2H8j2Z5P18saZ7xUBEdKkwAvz9VKPdLZoIJLr_f3cjHh0dS3t5dya_sHzVtpbQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77712073</pqid></control><display><type>article</type><title>Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience</title><source>EBSCOhost SPORTDiscus with Full Text</source><creator>ANSANI, LUCIA ; PERCOCO, GIAN FRANCO ; GUARDIGLI, GABRIELE ; TOSELLI, TIZIANO ; ANTONIOLI, GIAN ENRICO</creator><creatorcontrib>ANSANI, LUCIA ; PERCOCO, GIAN FRANCO ; GUARDIGLI, GABRIELE ; TOSELLI, TIZIANO ; ANTONIOLI, GIAN ENRICO</creatorcontrib><description>To assess the long‐term capability of single atrioven ticular (AV) lead VDD pacing systems using close atrial dipoles to assure reliable atrial guided pacing, the safety and efficacy of 86 VDD units implanted in 73 patients at a single center since November 1988 was reviewed. All patients suffered from advanced AV block with normal sinoatrial function. Sixty five patients received a LEM/CCS Twinal 30/30S system, four patients received a Vitatron‐Saphir system, and four patients received a Medtronic Thera VDR 8348 system. All patients underwent provocative tests in search of myopotential interference, and Holter recordings; in a group of patients who underwent pacemaker replacement a comparison was made between implant and replacement measurements. The mean follow‐up duration was 27.3 months. A high percentage of successfully VDD paced patients and a low incidence of pacemaker malfunction, regularly solved by pacemaker reprogramming, was reported. Atrial signal amplitudes comparable to those measured at implant were found at replacement in all patients. These data support the long‐term reliability of single AV lead VDD pacing systems with closely spaced atrial dipoles, as well as stable atrial sensing by floating bipolar atrial electrodes and effective atrial synchronous ventricular pacing over time.</description><identifier>ISSN: 0147-8389</identifier><identifier>EISSN: 1540-8159</identifier><identifier>DOI: 10.1111/j.1540-8159.1994.tb03764.x</identifier><identifier>PMID: 7845782</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Aged ; Aged, 80 and over ; closely spaced floating atrial dipole ; Electrocardiography ; Equipment Failure ; Female ; Follow-Up Studies ; Heart Block - physiopathology ; Heart Block - therapy ; Humans ; Male ; Middle Aged ; Pacemaker, Artificial - adverse effects ; single lead VDD pacing</subject><ispartof>Pacing and clinical electrophysiology, 1994-11, Vol.17 (11), p.1865-1869</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3</citedby><cites>FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7845782$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ANSANI, LUCIA</creatorcontrib><creatorcontrib>PERCOCO, GIAN FRANCO</creatorcontrib><creatorcontrib>GUARDIGLI, GABRIELE</creatorcontrib><creatorcontrib>TOSELLI, TIZIANO</creatorcontrib><creatorcontrib>ANTONIOLI, GIAN ENRICO</creatorcontrib><title>Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience</title><title>Pacing and clinical electrophysiology</title><addtitle>Pacing Clin Electrophysiol</addtitle><description>To assess the long‐term capability of single atrioven ticular (AV) lead VDD pacing systems using close atrial dipoles to assure reliable atrial guided pacing, the safety and efficacy of 86 VDD units implanted in 73 patients at a single center since November 1988 was reviewed. All patients suffered from advanced AV block with normal sinoatrial function. Sixty five patients received a LEM/CCS Twinal 30/30S system, four patients received a Vitatron‐Saphir system, and four patients received a Medtronic Thera VDR 8348 system. All patients underwent provocative tests in search of myopotential interference, and Holter recordings; in a group of patients who underwent pacemaker replacement a comparison was made between implant and replacement measurements. The mean follow‐up duration was 27.3 months. A high percentage of successfully VDD paced patients and a low incidence of pacemaker malfunction, regularly solved by pacemaker reprogramming, was reported. Atrial signal amplitudes comparable to those measured at implant were found at replacement in all patients. These data support the long‐term reliability of single AV lead VDD pacing systems with closely spaced atrial dipoles, as well as stable atrial sensing by floating bipolar atrial electrodes and effective atrial synchronous ventricular pacing over time.</description><subject>Aged</subject><subject>Aged, 80 and over</subject><subject>closely spaced floating atrial dipole</subject><subject>Electrocardiography</subject><subject>Equipment Failure</subject><subject>Female</subject><subject>Follow-Up Studies</subject><subject>Heart Block - physiopathology</subject><subject>Heart Block - therapy</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Pacemaker, Artificial - adverse effects</subject><subject>single lead VDD pacing</subject><issn>0147-8389</issn><issn>1540-8159</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNqVkE1v0zAYxy0EGmXwEZAsDtyS2XEcJztRdd2GFI2xliFOluM-GS7OC3YKzW0fHUetescXy_6_PHp-CH2gJKbhXGxjylMS5ZQXMS2KNB4qwkSWxvsXaHaSXqIZoamIcpYXr9Eb77eEkIyk_AydiTzlIk9m6Lns2qdoDa7BD2CNqow1w4i7Gq9M-2QBl6A2eD44oyxeja3-6bq223l8r3QwhC8_QOPxNz-9FrbzYEe86pWGU-zK9J0Ff4mvzR-IfoByeLnvwRloNbxFr2plPbw73udofb1cL26j8svN58W8jDTjjEdCZ1mlE8GTsI7KE8UEqWnFk03FK6G1UpwpnqSJToucqkowSvSmAi4UL2jNztHHQ23vut878INsjNdgrWohrCOFEDQhggXj5cGoXee9g1r2zjTKjZISOdGXWzkhlhNiOdGXR_pyH8Lvj1N2VQObU_SIO-ifDvpfY2H8j2Z5P18saZ7xUBEdKkwAvz9VKPdLZoIJLr_f3cjHh0dS3t5dya_sHzVtpbQ</recordid><startdate>199411</startdate><enddate>199411</enddate><creator>ANSANI, LUCIA</creator><creator>PERCOCO, GIAN FRANCO</creator><creator>GUARDIGLI, GABRIELE</creator><creator>TOSELLI, TIZIANO</creator><creator>ANTONIOLI, GIAN ENRICO</creator><general>Blackwell Publishing Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199411</creationdate><title>Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience</title><author>ANSANI, LUCIA ; PERCOCO, GIAN FRANCO ; GUARDIGLI, GABRIELE ; TOSELLI, TIZIANO ; ANTONIOLI, GIAN ENRICO</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Aged</topic><topic>Aged, 80 and over</topic><topic>closely spaced floating atrial dipole</topic><topic>Electrocardiography</topic><topic>Equipment Failure</topic><topic>Female</topic><topic>Follow-Up Studies</topic><topic>Heart Block - physiopathology</topic><topic>Heart Block - therapy</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Pacemaker, Artificial - adverse effects</topic><topic>single lead VDD pacing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ANSANI, LUCIA</creatorcontrib><creatorcontrib>PERCOCO, GIAN FRANCO</creatorcontrib><creatorcontrib>GUARDIGLI, GABRIELE</creatorcontrib><creatorcontrib>TOSELLI, TIZIANO</creatorcontrib><creatorcontrib>ANTONIOLI, GIAN ENRICO</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Pacing and clinical electrophysiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ANSANI, LUCIA</au><au>PERCOCO, GIAN FRANCO</au><au>GUARDIGLI, GABRIELE</au><au>TOSELLI, TIZIANO</au><au>ANTONIOLI, GIAN ENRICO</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience</atitle><jtitle>Pacing and clinical electrophysiology</jtitle><addtitle>Pacing Clin Electrophysiol</addtitle><date>1994-11</date><risdate>1994</risdate><volume>17</volume><issue>11</issue><spage>1865</spage><epage>1869</epage><pages>1865-1869</pages><issn>0147-8389</issn><eissn>1540-8159</eissn><abstract>To assess the long‐term capability of single atrioven ticular (AV) lead VDD pacing systems using close atrial dipoles to assure reliable atrial guided pacing, the safety and efficacy of 86 VDD units implanted in 73 patients at a single center since November 1988 was reviewed. All patients suffered from advanced AV block with normal sinoatrial function. Sixty five patients received a LEM/CCS Twinal 30/30S system, four patients received a Vitatron‐Saphir system, and four patients received a Medtronic Thera VDR 8348 system. All patients underwent provocative tests in search of myopotential interference, and Holter recordings; in a group of patients who underwent pacemaker replacement a comparison was made between implant and replacement measurements. The mean follow‐up duration was 27.3 months. A high percentage of successfully VDD paced patients and a low incidence of pacemaker malfunction, regularly solved by pacemaker reprogramming, was reported. Atrial signal amplitudes comparable to those measured at implant were found at replacement in all patients. These data support the long‐term reliability of single AV lead VDD pacing systems with closely spaced atrial dipoles, as well as stable atrial sensing by floating bipolar atrial electrodes and effective atrial synchronous ventricular pacing over time.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><pmid>7845782</pmid><doi>10.1111/j.1540-8159.1994.tb03764.x</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0147-8389
ispartof Pacing and clinical electrophysiology, 1994-11, Vol.17 (11), p.1865-1869
issn 0147-8389
1540-8159
language eng
recordid cdi_proquest_miscellaneous_77712073
source EBSCOhost SPORTDiscus with Full Text
subjects Aged
Aged, 80 and over
closely spaced floating atrial dipole
Electrocardiography
Equipment Failure
Female
Follow-Up Studies
Heart Block - physiopathology
Heart Block - therapy
Humans
Male
Middle Aged
Pacemaker, Artificial - adverse effects
single lead VDD pacing
title Long-Term Reliability of Single Lead Atrial Synchronous Pacing Systems Using Closely Spaced Atrial Dipoles: Five-Year Experience
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T21%3A07%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Long-Term%20Reliability%20of%20Single%20Lead%20Atrial%20Synchronous%20Pacing%20Systems%20Using%20Closely%20Spaced%20Atrial%20Dipoles:%20Five-Year%20Experience&rft.jtitle=Pacing%20and%20clinical%20electrophysiology&rft.au=ANSANI,%20LUCIA&rft.date=1994-11&rft.volume=17&rft.issue=11&rft.spage=1865&rft.epage=1869&rft.pages=1865-1869&rft.issn=0147-8389&rft.eissn=1540-8159&rft_id=info:doi/10.1111/j.1540-8159.1994.tb03764.x&rft_dat=%3Cproquest_cross%3E77712073%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3535-7c66bc2752838a82a370f1b52db5b7ccaa53a5242c4981ab7310cdbe57a591f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=77712073&rft_id=info:pmid/7845782&rfr_iscdi=true