New and old contrast agents: pharmacology, tissue opacification, and excretory urography

In equivalent doses for intravenous urograms conventional ionic contrast agents give iodine concentrations in the urine of approximately 30 mg iodine/ml, nonionic contrast media provide approximately 50 mg iodine/ml, and the ionic dimer Hexabrix approximately 70 mg iodine/mL. These new low osmolalit...

Full description

Saved in:
Bibliographic Details
Published in:Urologic radiology 1988-01, Vol.10 (1), p.2-5
Main Author: SPATARO, R. F
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In equivalent doses for intravenous urograms conventional ionic contrast agents give iodine concentrations in the urine of approximately 30 mg iodine/ml, nonionic contrast media provide approximately 50 mg iodine/ml, and the ionic dimer Hexabrix approximately 70 mg iodine/mL. These new low osmolality, contrast media provide significantly higher urinary iodine concentrations than conventional ionic contrast media, provide better diagnostic quality excretory urograms, better patient tolerance, and fewer adverse side-effects and serious reactions. These new low osmolality, contrast media have significant advantages in intravenous urography in both safety and efficacy when compared to conventional higher osmolality contrast media.
ISSN:0171-1091