New and old contrast agents: pharmacology, tissue opacification, and excretory urography
In equivalent doses for intravenous urograms conventional ionic contrast agents give iodine concentrations in the urine of approximately 30 mg iodine/ml, nonionic contrast media provide approximately 50 mg iodine/ml, and the ionic dimer Hexabrix approximately 70 mg iodine/mL. These new low osmolalit...
Saved in:
Published in: | Urologic radiology 1988-01, Vol.10 (1), p.2-5 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In equivalent doses for intravenous urograms conventional ionic contrast agents give iodine concentrations in the urine of approximately 30 mg iodine/ml, nonionic contrast media provide approximately 50 mg iodine/ml, and the ionic dimer Hexabrix approximately 70 mg iodine/mL. These new low osmolality, contrast media provide significantly higher urinary iodine concentrations than conventional ionic contrast media, provide better diagnostic quality excretory urograms, better patient tolerance, and fewer adverse side-effects and serious reactions. These new low osmolality, contrast media have significant advantages in intravenous urography in both safety and efficacy when compared to conventional higher osmolality contrast media. |
---|---|
ISSN: | 0171-1091 |
DOI: | 10.1007/BF02926526 |