Loading…

Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation

Pulsed and continuous‐wave (CW) lasers were compared as excitation sources for surface‐enhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signal‐to‐noise ratio and more sensitive detection by a factor of ∼50 compared with the high peak power, low repetit...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Raman spectroscopy 2005-06, Vol.36 (6-7), p.600-605
Main Authors: Littleford, Rachael E., Cunningham, Dale, Matousek, Pavel, Towrie, Michael, Parker, Anthony W., Khan, Imran, McComb, David, Ewen Smith, W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703
cites cdi_FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703
container_end_page 605
container_issue 6-7
container_start_page 600
container_title Journal of Raman spectroscopy
container_volume 36
creator Littleford, Rachael E.
Cunningham, Dale
Matousek, Pavel
Towrie, Michael
Parker, Anthony W.
Khan, Imran
McComb, David
Ewen Smith, W.
description Pulsed and continuous‐wave (CW) lasers were compared as excitation sources for surface‐enhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signal‐to‐noise ratio and more sensitive detection by a factor of ∼50 compared with the high peak power, low repetition rate pulsed configuration used. The SERRS intensity using a pulsed laser produced a non‐linear response with respect to changes in power of the laser. At powers of less than ∼0.012 mW, the absolute intensity under the peaks of the CW and pulsed SERRS spectra converged, suggesting that lower peak power, high repetition rate systems may be more effective excitation sources for SERRS. Transmission electron microscopy of pulsed laser‐irradiated silver particles showed significant sample damage and morphological changes. This problem was overcome with the use of a recirculating large‐volume flow cell system, providing a fresh sample for each measurement. A picosecond‐resolved time delay experiment found that SERRS intensity decreased by ∼60% when exposed to a 400 nm pump pulse and probed with a 529 nm pulse. As the time delay between pump and probe increased the system recovered gradually to ∼60% of the original SERRS intensity after 50 ps, where it remained constant. This suggests that the surface bonding between the silver and the dye is significantly perturbed, with some nanoscale diffusion occurring of the dye away from the metal surface. Hence chemical enhancement is temporarily prevented and electromagnetic enhancement is reduced as a function of 1/r3 as the dye moves away from the surface. Additionally, transient heating of the colloidal particles caused by the pulsed laser may also lead to plasmon shifts and changes in absorption intensity. Other factors such as surface annealing or decomposition of the silver particle or dye due the extreme temperature conditions may account for the permanent loss in SERRS intensity. Copyright © 2005 John Wiley & Sons, Ltd.
doi_str_mv 10.1002/jrs.1336
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_787071381</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>29560759</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703</originalsourceid><addsrcrecordid>eNp90EFLwzAUB_AgCs4p-BF6Ui-dL02bNEcdbipDxzbwJCHLXrXapTNp3fbtbZkIHvTy3jv8-PP4E3JKoUcBoss353uUMb5HOhSkCOMkSfZJB5gQIcQpPyRH3r8BgJScdsjztHaZNhiifdXW4CJw6EvbnsFEL7UNvNFVhS63L0Ht27mqC984bReBKW2V27qsfbjWnxgU2qMLcGPySld5aY_JQaYbffK9u2Q2uJn1b8PR4_CufzUKDeOchxnGERdmztOEUYOxkFxKuohkivFCApVUcIjn84zOhY4MRw6GJZGJojRjAliXnO9iV678qNFXapl7g0WhLTa_KZEKEJSltJFn_8pIJhxEIht4sYPGld47zNTK5UvttoqCaotWTdGqLbqh4Y6u8wK3fzp1P5n-9rmvcPPjtXtXXDCRqKeHoRqP2fWgPwbF2Rd5vY6D</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>29560759</pqid></control><display><type>article</type><title>Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Littleford, Rachael E. ; Cunningham, Dale ; Matousek, Pavel ; Towrie, Michael ; Parker, Anthony W. ; Khan, Imran ; McComb, David ; Ewen Smith, W.</creator><creatorcontrib>Littleford, Rachael E. ; Cunningham, Dale ; Matousek, Pavel ; Towrie, Michael ; Parker, Anthony W. ; Khan, Imran ; McComb, David ; Ewen Smith, W.</creatorcontrib><description>Pulsed and continuous‐wave (CW) lasers were compared as excitation sources for surface‐enhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signal‐to‐noise ratio and more sensitive detection by a factor of ∼50 compared with the high peak power, low repetition rate pulsed configuration used. The SERRS intensity using a pulsed laser produced a non‐linear response with respect to changes in power of the laser. At powers of less than ∼0.012 mW, the absolute intensity under the peaks of the CW and pulsed SERRS spectra converged, suggesting that lower peak power, high repetition rate systems may be more effective excitation sources for SERRS. Transmission electron microscopy of pulsed laser‐irradiated silver particles showed significant sample damage and morphological changes. This problem was overcome with the use of a recirculating large‐volume flow cell system, providing a fresh sample for each measurement. A picosecond‐resolved time delay experiment found that SERRS intensity decreased by ∼60% when exposed to a 400 nm pump pulse and probed with a 529 nm pulse. As the time delay between pump and probe increased the system recovered gradually to ∼60% of the original SERRS intensity after 50 ps, where it remained constant. This suggests that the surface bonding between the silver and the dye is significantly perturbed, with some nanoscale diffusion occurring of the dye away from the metal surface. Hence chemical enhancement is temporarily prevented and electromagnetic enhancement is reduced as a function of 1/r3 as the dye moves away from the surface. Additionally, transient heating of the colloidal particles caused by the pulsed laser may also lead to plasmon shifts and changes in absorption intensity. Other factors such as surface annealing or decomposition of the silver particle or dye due the extreme temperature conditions may account for the permanent loss in SERRS intensity. Copyright © 2005 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0377-0486</identifier><identifier>EISSN: 1097-4555</identifier><identifier>DOI: 10.1002/jrs.1336</identifier><language>eng</language><publisher>Chichester, UK: John Wiley &amp; Sons, Ltd</publisher><subject>Dyes ; Excitation ; Lasers ; Nanostructure ; Pulsed lasers ; Raman scattering ; Silver ; silver nanoparticles ; Spectra ; surface-enhanced resonance Raman scattering</subject><ispartof>Journal of Raman spectroscopy, 2005-06, Vol.36 (6-7), p.600-605</ispartof><rights>Copyright © 2005 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703</citedby><cites>FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Littleford, Rachael E.</creatorcontrib><creatorcontrib>Cunningham, Dale</creatorcontrib><creatorcontrib>Matousek, Pavel</creatorcontrib><creatorcontrib>Towrie, Michael</creatorcontrib><creatorcontrib>Parker, Anthony W.</creatorcontrib><creatorcontrib>Khan, Imran</creatorcontrib><creatorcontrib>McComb, David</creatorcontrib><creatorcontrib>Ewen Smith, W.</creatorcontrib><title>Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation</title><title>Journal of Raman spectroscopy</title><addtitle>J. Raman Spectrosc</addtitle><description>Pulsed and continuous‐wave (CW) lasers were compared as excitation sources for surface‐enhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signal‐to‐noise ratio and more sensitive detection by a factor of ∼50 compared with the high peak power, low repetition rate pulsed configuration used. The SERRS intensity using a pulsed laser produced a non‐linear response with respect to changes in power of the laser. At powers of less than ∼0.012 mW, the absolute intensity under the peaks of the CW and pulsed SERRS spectra converged, suggesting that lower peak power, high repetition rate systems may be more effective excitation sources for SERRS. Transmission electron microscopy of pulsed laser‐irradiated silver particles showed significant sample damage and morphological changes. This problem was overcome with the use of a recirculating large‐volume flow cell system, providing a fresh sample for each measurement. A picosecond‐resolved time delay experiment found that SERRS intensity decreased by ∼60% when exposed to a 400 nm pump pulse and probed with a 529 nm pulse. As the time delay between pump and probe increased the system recovered gradually to ∼60% of the original SERRS intensity after 50 ps, where it remained constant. This suggests that the surface bonding between the silver and the dye is significantly perturbed, with some nanoscale diffusion occurring of the dye away from the metal surface. Hence chemical enhancement is temporarily prevented and electromagnetic enhancement is reduced as a function of 1/r3 as the dye moves away from the surface. Additionally, transient heating of the colloidal particles caused by the pulsed laser may also lead to plasmon shifts and changes in absorption intensity. Other factors such as surface annealing or decomposition of the silver particle or dye due the extreme temperature conditions may account for the permanent loss in SERRS intensity. Copyright © 2005 John Wiley &amp; Sons, Ltd.</description><subject>Dyes</subject><subject>Excitation</subject><subject>Lasers</subject><subject>Nanostructure</subject><subject>Pulsed lasers</subject><subject>Raman scattering</subject><subject>Silver</subject><subject>silver nanoparticles</subject><subject>Spectra</subject><subject>surface-enhanced resonance Raman scattering</subject><issn>0377-0486</issn><issn>1097-4555</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp90EFLwzAUB_AgCs4p-BF6Ui-dL02bNEcdbipDxzbwJCHLXrXapTNp3fbtbZkIHvTy3jv8-PP4E3JKoUcBoss353uUMb5HOhSkCOMkSfZJB5gQIcQpPyRH3r8BgJScdsjztHaZNhiifdXW4CJw6EvbnsFEL7UNvNFVhS63L0Ht27mqC984bReBKW2V27qsfbjWnxgU2qMLcGPySld5aY_JQaYbffK9u2Q2uJn1b8PR4_CufzUKDeOchxnGERdmztOEUYOxkFxKuohkivFCApVUcIjn84zOhY4MRw6GJZGJojRjAliXnO9iV678qNFXapl7g0WhLTa_KZEKEJSltJFn_8pIJhxEIht4sYPGld47zNTK5UvttoqCaotWTdGqLbqh4Y6u8wK3fzp1P5n-9rmvcPPjtXtXXDCRqKeHoRqP2fWgPwbF2Rd5vY6D</recordid><startdate>200506</startdate><enddate>200506</enddate><creator>Littleford, Rachael E.</creator><creator>Cunningham, Dale</creator><creator>Matousek, Pavel</creator><creator>Towrie, Michael</creator><creator>Parker, Anthony W.</creator><creator>Khan, Imran</creator><creator>McComb, David</creator><creator>Ewen Smith, W.</creator><general>John Wiley &amp; Sons, Ltd</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>200506</creationdate><title>Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation</title><author>Littleford, Rachael E. ; Cunningham, Dale ; Matousek, Pavel ; Towrie, Michael ; Parker, Anthony W. ; Khan, Imran ; McComb, David ; Ewen Smith, W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Dyes</topic><topic>Excitation</topic><topic>Lasers</topic><topic>Nanostructure</topic><topic>Pulsed lasers</topic><topic>Raman scattering</topic><topic>Silver</topic><topic>silver nanoparticles</topic><topic>Spectra</topic><topic>surface-enhanced resonance Raman scattering</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Littleford, Rachael E.</creatorcontrib><creatorcontrib>Cunningham, Dale</creatorcontrib><creatorcontrib>Matousek, Pavel</creatorcontrib><creatorcontrib>Towrie, Michael</creatorcontrib><creatorcontrib>Parker, Anthony W.</creatorcontrib><creatorcontrib>Khan, Imran</creatorcontrib><creatorcontrib>McComb, David</creatorcontrib><creatorcontrib>Ewen Smith, W.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of Raman spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Littleford, Rachael E.</au><au>Cunningham, Dale</au><au>Matousek, Pavel</au><au>Towrie, Michael</au><au>Parker, Anthony W.</au><au>Khan, Imran</au><au>McComb, David</au><au>Ewen Smith, W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation</atitle><jtitle>Journal of Raman spectroscopy</jtitle><addtitle>J. Raman Spectrosc</addtitle><date>2005-06</date><risdate>2005</risdate><volume>36</volume><issue>6-7</issue><spage>600</spage><epage>605</epage><pages>600-605</pages><issn>0377-0486</issn><eissn>1097-4555</eissn><abstract>Pulsed and continuous‐wave (CW) lasers were compared as excitation sources for surface‐enhanced resonance Raman scattering (SERRS). CW excitation provided SERRS spectra with a greater signal‐to‐noise ratio and more sensitive detection by a factor of ∼50 compared with the high peak power, low repetition rate pulsed configuration used. The SERRS intensity using a pulsed laser produced a non‐linear response with respect to changes in power of the laser. At powers of less than ∼0.012 mW, the absolute intensity under the peaks of the CW and pulsed SERRS spectra converged, suggesting that lower peak power, high repetition rate systems may be more effective excitation sources for SERRS. Transmission electron microscopy of pulsed laser‐irradiated silver particles showed significant sample damage and morphological changes. This problem was overcome with the use of a recirculating large‐volume flow cell system, providing a fresh sample for each measurement. A picosecond‐resolved time delay experiment found that SERRS intensity decreased by ∼60% when exposed to a 400 nm pump pulse and probed with a 529 nm pulse. As the time delay between pump and probe increased the system recovered gradually to ∼60% of the original SERRS intensity after 50 ps, where it remained constant. This suggests that the surface bonding between the silver and the dye is significantly perturbed, with some nanoscale diffusion occurring of the dye away from the metal surface. Hence chemical enhancement is temporarily prevented and electromagnetic enhancement is reduced as a function of 1/r3 as the dye moves away from the surface. Additionally, transient heating of the colloidal particles caused by the pulsed laser may also lead to plasmon shifts and changes in absorption intensity. Other factors such as surface annealing or decomposition of the silver particle or dye due the extreme temperature conditions may account for the permanent loss in SERRS intensity. Copyright © 2005 John Wiley &amp; Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley &amp; Sons, Ltd</pub><doi>10.1002/jrs.1336</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0377-0486
ispartof Journal of Raman spectroscopy, 2005-06, Vol.36 (6-7), p.600-605
issn 0377-0486
1097-4555
language eng
recordid cdi_proquest_miscellaneous_787071381
source Wiley-Blackwell Read & Publish Collection
subjects Dyes
Excitation
Lasers
Nanostructure
Pulsed lasers
Raman scattering
Silver
silver nanoparticles
Spectra
surface-enhanced resonance Raman scattering
title Surface-enhanced resonance Raman scattering using pulsed and continuous-wave laser excitation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A03%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Surface-enhanced%20resonance%20Raman%20scattering%20using%20pulsed%20and%20continuous-wave%20laser%20excitation&rft.jtitle=Journal%20of%20Raman%20spectroscopy&rft.au=Littleford,%20Rachael%20E.&rft.date=2005-06&rft.volume=36&rft.issue=6-7&rft.spage=600&rft.epage=605&rft.pages=600-605&rft.issn=0377-0486&rft.eissn=1097-4555&rft_id=info:doi/10.1002/jrs.1336&rft_dat=%3Cproquest_cross%3E29560759%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3666-fe4267cb68531ce4796991d298e4d901917604bbf1b7a2c6e60c352c228f3703%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=29560759&rft_id=info:pmid/&rfr_iscdi=true