Loading…
Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode
The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumula...
Saved in:
Published in: | Materials Science & Engineering C 2010-07, Vol.30 (6), p.833-838 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823 |
---|---|
cites | cdi_FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823 |
container_end_page | 838 |
container_issue | 6 |
container_start_page | 833 |
container_title | Materials Science & Engineering C |
container_volume | 30 |
creator | El Mhammedi, M.A. Achak, M. Bakasse, M. Bachirat, R. Chtaini, A. |
description | The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumulation time, kaolin loading and measuring solution pH. Square wave voltammetric response showed a linear calibration curve in the range from 3.9
×
10
−
9
to 9
×
10
−
5
mol
L
−
1
with a detection limit of 2
×
10
−
10
mol
L
−
1
at kaolin-modified carbon paste electrode. As a result, it was found that there was feasibility in the use of kaolin to improve the carbon paste electrode properties. |
doi_str_mv | 10.1016/j.msec.2010.03.019 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_787223048</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0928493110000792</els_id><sourcerecordid>787223048</sourcerecordid><originalsourceid>FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7-AU-5eWrNR01T8LKIX7DgRcFbSJMJZG2bbpIK_nuzrGdhYIbhfYd5H4SuKakpoeJ2V48JTM1IWRBeE9qdoBWVLa_KSE_RinRMVk3H6Tm6SGlHiJC8ZSv0uTFmGZdBZx8mrCeLc9QG8Ag6LRFGmDIODs866v2iMy71pcPgp2oM1jsPFhsd--KddcqAYQCTY7Bwic6cHhJc_fU1-nh6fH94qbZvz68Pm21lOGe5spzIDmirRSMZtJI2Dspnmgkhe3BNIzqQwjlOeyLvoDWC9QBArJVMdpLxNbo53p1j2C-Qshp9MjAMeoKwJNXKljFOGlmU7Kg0MaQUwak5-lHHH0WJOlBUO3WgqA4UFeGqoCum-6MJSoZvD1El42EyYH0sSZUN_j_7L6v9fBI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>787223048</pqid></control><display><type>article</type><title>Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode</title><source>ScienceDirect Freedom Collection</source><creator>El Mhammedi, M.A. ; Achak, M. ; Bakasse, M. ; Bachirat, R. ; Chtaini, A.</creator><creatorcontrib>El Mhammedi, M.A. ; Achak, M. ; Bakasse, M. ; Bachirat, R. ; Chtaini, A.</creatorcontrib><description>The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumulation time, kaolin loading and measuring solution pH. Square wave voltammetric response showed a linear calibration curve in the range from 3.9
×
10
−
9
to 9
×
10
−
5
mol
L
−
1
with a detection limit of 2
×
10
−
10
mol
L
−
1
at kaolin-modified carbon paste electrode. As a result, it was found that there was feasibility in the use of kaolin to improve the carbon paste electrode properties.</description><identifier>ISSN: 0928-4931</identifier><identifier>EISSN: 1873-0191</identifier><identifier>DOI: 10.1016/j.msec.2010.03.019</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Biomimetic materials ; Calibration ; Carbon ; Carbon paste electrode ; Electrodes ; Feasibility ; Kaolin ; Paraquat ; Pastes ; Square wave voltammetry ; Square waves ; Voltammetry</subject><ispartof>Materials Science & Engineering C, 2010-07, Vol.30 (6), p.833-838</ispartof><rights>2010 Elsevier B.V.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823</citedby><cites>FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>El Mhammedi, M.A.</creatorcontrib><creatorcontrib>Achak, M.</creatorcontrib><creatorcontrib>Bakasse, M.</creatorcontrib><creatorcontrib>Bachirat, R.</creatorcontrib><creatorcontrib>Chtaini, A.</creatorcontrib><title>Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode</title><title>Materials Science & Engineering C</title><description>The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumulation time, kaolin loading and measuring solution pH. Square wave voltammetric response showed a linear calibration curve in the range from 3.9
×
10
−
9
to 9
×
10
−
5
mol
L
−
1
with a detection limit of 2
×
10
−
10
mol
L
−
1
at kaolin-modified carbon paste electrode. As a result, it was found that there was feasibility in the use of kaolin to improve the carbon paste electrode properties.</description><subject>Biomimetic materials</subject><subject>Calibration</subject><subject>Carbon</subject><subject>Carbon paste electrode</subject><subject>Electrodes</subject><subject>Feasibility</subject><subject>Kaolin</subject><subject>Paraquat</subject><subject>Pastes</subject><subject>Square wave voltammetry</subject><subject>Square waves</subject><subject>Voltammetry</subject><issn>0928-4931</issn><issn>1873-0191</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7-AU-5eWrNR01T8LKIX7DgRcFbSJMJZG2bbpIK_nuzrGdhYIbhfYd5H4SuKakpoeJ2V48JTM1IWRBeE9qdoBWVLa_KSE_RinRMVk3H6Tm6SGlHiJC8ZSv0uTFmGZdBZx8mrCeLc9QG8Ag6LRFGmDIODs866v2iMy71pcPgp2oM1jsPFhsd--KddcqAYQCTY7Bwic6cHhJc_fU1-nh6fH94qbZvz68Pm21lOGe5spzIDmirRSMZtJI2Dspnmgkhe3BNIzqQwjlOeyLvoDWC9QBArJVMdpLxNbo53p1j2C-Qshp9MjAMeoKwJNXKljFOGlmU7Kg0MaQUwak5-lHHH0WJOlBUO3WgqA4UFeGqoCum-6MJSoZvD1El42EyYH0sSZUN_j_7L6v9fBI</recordid><startdate>20100720</startdate><enddate>20100720</enddate><creator>El Mhammedi, M.A.</creator><creator>Achak, M.</creator><creator>Bakasse, M.</creator><creator>Bachirat, R.</creator><creator>Chtaini, A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20100720</creationdate><title>Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode</title><author>El Mhammedi, M.A. ; Achak, M. ; Bakasse, M. ; Bachirat, R. ; Chtaini, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Biomimetic materials</topic><topic>Calibration</topic><topic>Carbon</topic><topic>Carbon paste electrode</topic><topic>Electrodes</topic><topic>Feasibility</topic><topic>Kaolin</topic><topic>Paraquat</topic><topic>Pastes</topic><topic>Square wave voltammetry</topic><topic>Square waves</topic><topic>Voltammetry</topic><toplevel>online_resources</toplevel><creatorcontrib>El Mhammedi, M.A.</creatorcontrib><creatorcontrib>Achak, M.</creatorcontrib><creatorcontrib>Bakasse, M.</creatorcontrib><creatorcontrib>Bachirat, R.</creatorcontrib><creatorcontrib>Chtaini, A.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Materials Science & Engineering C</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>El Mhammedi, M.A.</au><au>Achak, M.</au><au>Bakasse, M.</au><au>Bachirat, R.</au><au>Chtaini, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode</atitle><jtitle>Materials Science & Engineering C</jtitle><date>2010-07-20</date><risdate>2010</risdate><volume>30</volume><issue>6</issue><spage>833</spage><epage>838</epage><pages>833-838</pages><issn>0928-4931</issn><eissn>1873-0191</eissn><abstract>The carbon paste electrode modified by kaolin (KCPE) has been utilized for the determination of pesticides with high sensitivity based on their redox behavior. The experiment is performed on the use of cyclic and square wave voltammetry. Experimental conditions were optimized by varying the accumulation time, kaolin loading and measuring solution pH. Square wave voltammetric response showed a linear calibration curve in the range from 3.9
×
10
−
9
to 9
×
10
−
5
mol
L
−
1
with a detection limit of 2
×
10
−
10
mol
L
−
1
at kaolin-modified carbon paste electrode. As a result, it was found that there was feasibility in the use of kaolin to improve the carbon paste electrode properties.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.msec.2010.03.019</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0928-4931 |
ispartof | Materials Science & Engineering C, 2010-07, Vol.30 (6), p.833-838 |
issn | 0928-4931 1873-0191 |
language | eng |
recordid | cdi_proquest_miscellaneous_787223048 |
source | ScienceDirect Freedom Collection |
subjects | Biomimetic materials Calibration Carbon Carbon paste electrode Electrodes Feasibility Kaolin Paraquat Pastes Square wave voltammetry Square waves Voltammetry |
title | Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T02%3A32%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accumulation%20and%20trace%20measurement%20of%20paraquat%20at%20kaolin-modified%20carbon%20paste%20electrode&rft.jtitle=Materials%20Science%20&%20Engineering%20C&rft.au=El%20Mhammedi,%20M.A.&rft.date=2010-07-20&rft.volume=30&rft.issue=6&rft.spage=833&rft.epage=838&rft.pages=833-838&rft.issn=0928-4931&rft.eissn=1873-0191&rft_id=info:doi/10.1016/j.msec.2010.03.019&rft_dat=%3Cproquest_cross%3E787223048%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c332t-d3089e17a6482e7814fe837a2668bef4469e86ff31b085e7c62beee0dd8289823%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=787223048&rft_id=info:pmid/&rfr_iscdi=true |