Loading…
Bonded orthodontic retainers: The wire-composite interface
The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aime...
Saved in:
Published in: | American journal of orthodontics and dentofacial orthopedics 1997, Vol.111 (1), p.67-74 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3 |
---|---|
cites | cdi_FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3 |
container_end_page | 74 |
container_issue | 1 |
container_start_page | 67 |
container_title | American journal of orthodontics and dentofacial orthopedics |
container_volume | 111 |
creator | Bearn, David R. McCabe, John F. Gordon, Peter H. Aird, John C. |
description | The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. An in vitro model was developed to simulate the forces encountered at the wire/composite interface. No significant difference was detected between different multistrand wire types and diameters with regard to retention in composite. Wires were placed in one of three groups according to surface characteristics identified with scanning electron microscopy. Increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite. Thickness of composite greater than 1.0 mm overlying the wire may give little clinical advantage. Greater force was required to detach the wire from Concise Orthodontic (3M Unitek) than any other composite tested. In vitro abrasion resistance testing found Heliosit Orthodontic (Vivadent) and Right On (TP Orthodontics, Inc.) to have poor abrasion resistance, whereas Concise Orthodontic and Transbond (3M Unitek) had abrasion resistance comparable with restorative composites. Clinical recommendations are made based on these findings. (Am J Orthod Dentofac Orthop 1997;111:67-74.) |
doi_str_mv | 10.1016/S0889-5406(97)70304-4 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78806207</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0889540697703044</els_id><sourcerecordid>78806207</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMotVZ_QmFWoovRO8nMJOlGtPiCggvrOqSZGxppJzVJFf-90wfduroXzjn38REyLOCmgKK-fQchZF6VUF9Jfs2BQZmXR6RfgOR5zSt6TPoHyyk5i_ETAGRJoUd6suskrftk9ODbBpvMhzT3jW-TM1nApF2LIY6y6RyzHxcwN3658tElzFybMFht8JycWL2IeLGvA_Lx9Dgdv-STt-fX8f0kN6yGlGuQFVS0MCh0xU13EUPQVjSzWWOlYGAE0BpNKbixjGtW8IJVtWSWllRazQbkcjd3FfzXGmNSSxcNLha6Rb-OigsBNQXeGaud0QQfY0CrVsEtdfhVBagNM7VlpjZAlORqy0yVXW64X7CeLbE5pPaQOv1up2P35bfDoKJx2BpsOjImqca7fzb8AQSGewI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78806207</pqid></control><display><type>article</type><title>Bonded orthodontic retainers: The wire-composite interface</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Bearn, David R. ; McCabe, John F. ; Gordon, Peter H. ; Aird, John C.</creator><creatorcontrib>Bearn, David R. ; McCabe, John F. ; Gordon, Peter H. ; Aird, John C.</creatorcontrib><description>The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. An in vitro model was developed to simulate the forces encountered at the wire/composite interface. No significant difference was detected between different multistrand wire types and diameters with regard to retention in composite. Wires were placed in one of three groups according to surface characteristics identified with scanning electron microscopy. Increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite. Thickness of composite greater than 1.0 mm overlying the wire may give little clinical advantage. Greater force was required to detach the wire from Concise Orthodontic (3M Unitek) than any other composite tested. In vitro abrasion resistance testing found Heliosit Orthodontic (Vivadent) and Right On (TP Orthodontics, Inc.) to have poor abrasion resistance, whereas Concise Orthodontic and Transbond (3M Unitek) had abrasion resistance comparable with restorative composites. Clinical recommendations are made based on these findings. (Am J Orthod Dentofac Orthop 1997;111:67-74.)</description><identifier>ISSN: 0889-5406</identifier><identifier>EISSN: 1097-6752</identifier><identifier>DOI: 10.1016/S0889-5406(97)70304-4</identifier><identifier>PMID: 9009926</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Adhesiveness ; Analysis of Variance ; Bisphenol A-Glycidyl Methacrylate ; Composite Resins - chemistry ; Dental Bonding ; Dentistry ; Humans ; Materials Testing ; Microscopy, Electron, Scanning ; Orthodontic Appliance Design ; Orthodontic Retainers ; Orthodontic Wires ; Resin Cements ; Statistics, Nonparametric ; Surface Properties</subject><ispartof>American journal of orthodontics and dentofacial orthopedics, 1997, Vol.111 (1), p.67-74</ispartof><rights>1997 American Association of Orthodontists</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3</citedby><cites>FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9009926$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Bearn, David R.</creatorcontrib><creatorcontrib>McCabe, John F.</creatorcontrib><creatorcontrib>Gordon, Peter H.</creatorcontrib><creatorcontrib>Aird, John C.</creatorcontrib><title>Bonded orthodontic retainers: The wire-composite interface</title><title>American journal of orthodontics and dentofacial orthopedics</title><addtitle>Am J Orthod Dentofacial Orthop</addtitle><description>The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. An in vitro model was developed to simulate the forces encountered at the wire/composite interface. No significant difference was detected between different multistrand wire types and diameters with regard to retention in composite. Wires were placed in one of three groups according to surface characteristics identified with scanning electron microscopy. Increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite. Thickness of composite greater than 1.0 mm overlying the wire may give little clinical advantage. Greater force was required to detach the wire from Concise Orthodontic (3M Unitek) than any other composite tested. In vitro abrasion resistance testing found Heliosit Orthodontic (Vivadent) and Right On (TP Orthodontics, Inc.) to have poor abrasion resistance, whereas Concise Orthodontic and Transbond (3M Unitek) had abrasion resistance comparable with restorative composites. Clinical recommendations are made based on these findings. (Am J Orthod Dentofac Orthop 1997;111:67-74.)</description><subject>Adhesiveness</subject><subject>Analysis of Variance</subject><subject>Bisphenol A-Glycidyl Methacrylate</subject><subject>Composite Resins - chemistry</subject><subject>Dental Bonding</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Materials Testing</subject><subject>Microscopy, Electron, Scanning</subject><subject>Orthodontic Appliance Design</subject><subject>Orthodontic Retainers</subject><subject>Orthodontic Wires</subject><subject>Resin Cements</subject><subject>Statistics, Nonparametric</subject><subject>Surface Properties</subject><issn>0889-5406</issn><issn>1097-6752</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkEtLAzEUhYMotVZ_QmFWoovRO8nMJOlGtPiCggvrOqSZGxppJzVJFf-90wfduroXzjn38REyLOCmgKK-fQchZF6VUF9Jfs2BQZmXR6RfgOR5zSt6TPoHyyk5i_ETAGRJoUd6suskrftk9ODbBpvMhzT3jW-TM1nApF2LIY6y6RyzHxcwN3658tElzFybMFht8JycWL2IeLGvA_Lx9Dgdv-STt-fX8f0kN6yGlGuQFVS0MCh0xU13EUPQVjSzWWOlYGAE0BpNKbixjGtW8IJVtWSWllRazQbkcjd3FfzXGmNSSxcNLha6Rb-OigsBNQXeGaud0QQfY0CrVsEtdfhVBagNM7VlpjZAlORqy0yVXW64X7CeLbE5pPaQOv1up2P35bfDoKJx2BpsOjImqca7fzb8AQSGewI</recordid><startdate>1997</startdate><enddate>1997</enddate><creator>Bearn, David R.</creator><creator>McCabe, John F.</creator><creator>Gordon, Peter H.</creator><creator>Aird, John C.</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1997</creationdate><title>Bonded orthodontic retainers: The wire-composite interface</title><author>Bearn, David R. ; McCabe, John F. ; Gordon, Peter H. ; Aird, John C.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Adhesiveness</topic><topic>Analysis of Variance</topic><topic>Bisphenol A-Glycidyl Methacrylate</topic><topic>Composite Resins - chemistry</topic><topic>Dental Bonding</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Materials Testing</topic><topic>Microscopy, Electron, Scanning</topic><topic>Orthodontic Appliance Design</topic><topic>Orthodontic Retainers</topic><topic>Orthodontic Wires</topic><topic>Resin Cements</topic><topic>Statistics, Nonparametric</topic><topic>Surface Properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bearn, David R.</creatorcontrib><creatorcontrib>McCabe, John F.</creatorcontrib><creatorcontrib>Gordon, Peter H.</creatorcontrib><creatorcontrib>Aird, John C.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>American journal of orthodontics and dentofacial orthopedics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bearn, David R.</au><au>McCabe, John F.</au><au>Gordon, Peter H.</au><au>Aird, John C.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bonded orthodontic retainers: The wire-composite interface</atitle><jtitle>American journal of orthodontics and dentofacial orthopedics</jtitle><addtitle>Am J Orthod Dentofacial Orthop</addtitle><date>1997</date><risdate>1997</risdate><volume>111</volume><issue>1</issue><spage>67</spage><epage>74</epage><pages>67-74</pages><issn>0889-5406</issn><eissn>1097-6752</eissn><abstract>The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. An in vitro model was developed to simulate the forces encountered at the wire/composite interface. No significant difference was detected between different multistrand wire types and diameters with regard to retention in composite. Wires were placed in one of three groups according to surface characteristics identified with scanning electron microscopy. Increasing the thickness of composite overlying the wire increased the force required to detach the wire from the composite. Thickness of composite greater than 1.0 mm overlying the wire may give little clinical advantage. Greater force was required to detach the wire from Concise Orthodontic (3M Unitek) than any other composite tested. In vitro abrasion resistance testing found Heliosit Orthodontic (Vivadent) and Right On (TP Orthodontics, Inc.) to have poor abrasion resistance, whereas Concise Orthodontic and Transbond (3M Unitek) had abrasion resistance comparable with restorative composites. Clinical recommendations are made based on these findings. (Am J Orthod Dentofac Orthop 1997;111:67-74.)</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>9009926</pmid><doi>10.1016/S0889-5406(97)70304-4</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0889-5406 |
ispartof | American journal of orthodontics and dentofacial orthopedics, 1997, Vol.111 (1), p.67-74 |
issn | 0889-5406 1097-6752 |
language | eng |
recordid | cdi_proquest_miscellaneous_78806207 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Adhesiveness Analysis of Variance Bisphenol A-Glycidyl Methacrylate Composite Resins - chemistry Dental Bonding Dentistry Humans Materials Testing Microscopy, Electron, Scanning Orthodontic Appliance Design Orthodontic Retainers Orthodontic Wires Resin Cements Statistics, Nonparametric Surface Properties |
title | Bonded orthodontic retainers: The wire-composite interface |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A53%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bonded%20orthodontic%20retainers:%20The%20wire-composite%20interface&rft.jtitle=American%20journal%20of%20orthodontics%20and%20dentofacial%20orthopedics&rft.au=Bearn,%20David%20R.&rft.date=1997&rft.volume=111&rft.issue=1&rft.spage=67&rft.epage=74&rft.pages=67-74&rft.issn=0889-5406&rft.eissn=1097-6752&rft_id=info:doi/10.1016/S0889-5406(97)70304-4&rft_dat=%3Cproquest_cross%3E78806207%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c360t-a0950521ce8a57c8893e0af8dbbdf9830c8026ec487cf37a317135693f2429fa3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=78806207&rft_id=info:pmid/9009926&rfr_iscdi=true |