Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead
One hundred and twenty‐two permanent pacemaker lead placements were performed by two physicians, utilizing a recently released peelaway sheath introducer with a splittable hemostatic valve. All introducers performed well and provided convenient bloodless surgical fields, as expected from the presenc...
Saved in:
Published in: | Catheterization and cardiovascular diagnosis 1997-03, Vol.40 (3), p.326-327 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c4306-e893b9100f0536d4a8f73af7eff18a47628a6fe75a7516b88213709fe66237b23 |
container_end_page | 327 |
container_issue | 3 |
container_start_page | 326 |
container_title | Catheterization and cardiovascular diagnosis |
container_volume | 40 |
creator | Lee, Hongyo H. |
description | One hundred and twenty‐two permanent pacemaker lead placements were performed by two physicians, utilizing a recently released peelaway sheath introducer with a splittable hemostatic valve. All introducers performed well and provided convenient bloodless surgical fields, as expected from the presence of a valve. Cathet. Cardiovasc. Diagn. 40:326–327, 1997. © 1997 Wiley‐Liss Inc. |
doi_str_mv | 10.1002/(SICI)1097-0304(199703)40:3<326::AID-CCD26>3.0.CO;2-L |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78864593</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>78864593</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4306-e893b9100f0536d4a8f73af7eff18a47628a6fe75a7516b88213709fe66237b23</originalsourceid><addsrcrecordid>eNqFkV1v0zAUhiMEGmXwE5B8gdB2keLYiR2XD2nKWFdUqDQYXB6dpsdqNqcJcbLSf09Cq96AxJV1Pvzo1XmC4H3ExxHn4s3Z11k2O4-40SGXPD6LjNFcnsd8It9JoSaTi9llmGWXQn2QYz7OFm9FOH8UjI4_Hgcjzk0aqkSZp8Ez7-8457GS8UlwYrgSWqpRsL31ZDu3Ie9ZZRmymsjhFnfMrwnbNSs2bVOtupwati36GpmvXdG2uHTE1lRWvsW2yNkDugditmpY7TCnkjbtAKypKXEzFPXQxfue4whXz4MnFp2nF4f3NLi9-vgtuw7ni-ksu5iHeSy5Cik1cmn6e1ieSLWKMbVaotVkbZRirJVIUVnSCeokUss0FZHU3FhSSki9FPI0eL3n1k31syPfQln4nJzrQ1WdB52mKk6MlMcAeVN535CFuilKbHYQcRiEAAxCYDgvDOeFvRCIOUjohQD0QuCPkL7BIVuAgHnPfXkI0C1LWh2pBwP9_NVhjj5HZxvc5IU_ronEpGnM-7Xv-7Vt4Wj3V7b_RPtXsn2jB4d7cOFb-nUEY3MPSkudwI8vU7i-MdNPVzcRfJa_Aaeuwo0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78864593</pqid></control><display><type>article</type><title>Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead</title><source>Wiley</source><creator>Lee, Hongyo H.</creator><creatorcontrib>Lee, Hongyo H.</creatorcontrib><description>One hundred and twenty‐two permanent pacemaker lead placements were performed by two physicians, utilizing a recently released peelaway sheath introducer with a splittable hemostatic valve. All introducers performed well and provided convenient bloodless surgical fields, as expected from the presence of a valve. Cathet. Cardiovasc. Diagn. 40:326–327, 1997. © 1997 Wiley‐Liss Inc.</description><identifier>ISSN: 0098-6569</identifier><identifier>EISSN: 1097-0304</identifier><identifier>DOI: 10.1002/(SICI)1097-0304(199703)40:3<326::AID-CCD26>3.0.CO;2-L</identifier><identifier>PMID: 9062736</identifier><identifier>CODEN: CCDIDC</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Aged ; Biological and medical sciences ; Diseases of the cardiovascular system ; Equipment Design ; Equipment Safety ; Female ; Hemostasis, Surgical - instrumentation ; Hemostasis, Surgical - methods ; Humans ; Male ; Medical sciences ; Middle Aged ; Pacemaker, Artificial ; peelaway sheath ; peelaway sheath introducer with splittable hemostatic valve ; permanent pacemaker implantation ; permanent pacemaker lead ; Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><ispartof>Catheterization and cardiovascular diagnosis, 1997-03, Vol.40 (3), p.326-327</ispartof><rights>Copyright © 1997 Wiley‐Liss, Inc.</rights><rights>1997 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c4306-e893b9100f0536d4a8f73af7eff18a47628a6fe75a7516b88213709fe66237b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=2598840$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9062736$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lee, Hongyo H.</creatorcontrib><title>Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead</title><title>Catheterization and cardiovascular diagnosis</title><addtitle>Cathet. Cardiovasc. Diagn</addtitle><description>One hundred and twenty‐two permanent pacemaker lead placements were performed by two physicians, utilizing a recently released peelaway sheath introducer with a splittable hemostatic valve. All introducers performed well and provided convenient bloodless surgical fields, as expected from the presence of a valve. Cathet. Cardiovasc. Diagn. 40:326–327, 1997. © 1997 Wiley‐Liss Inc.</description><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Diseases of the cardiovascular system</subject><subject>Equipment Design</subject><subject>Equipment Safety</subject><subject>Female</subject><subject>Hemostasis, Surgical - instrumentation</subject><subject>Hemostasis, Surgical - methods</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Pacemaker, Artificial</subject><subject>peelaway sheath</subject><subject>peelaway sheath introducer with splittable hemostatic valve</subject><subject>permanent pacemaker implantation</subject><subject>permanent pacemaker lead</subject><subject>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</subject><issn>0098-6569</issn><issn>1097-0304</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkV1v0zAUhiMEGmXwE5B8gdB2keLYiR2XD2nKWFdUqDQYXB6dpsdqNqcJcbLSf09Cq96AxJV1Pvzo1XmC4H3ExxHn4s3Z11k2O4-40SGXPD6LjNFcnsd8It9JoSaTi9llmGWXQn2QYz7OFm9FOH8UjI4_Hgcjzk0aqkSZp8Ez7-8457GS8UlwYrgSWqpRsL31ZDu3Ie9ZZRmymsjhFnfMrwnbNSs2bVOtupwati36GpmvXdG2uHTE1lRWvsW2yNkDugditmpY7TCnkjbtAKypKXEzFPXQxfue4whXz4MnFp2nF4f3NLi9-vgtuw7ni-ksu5iHeSy5Cik1cmn6e1ieSLWKMbVaotVkbZRirJVIUVnSCeokUss0FZHU3FhSSki9FPI0eL3n1k31syPfQln4nJzrQ1WdB52mKk6MlMcAeVN535CFuilKbHYQcRiEAAxCYDgvDOeFvRCIOUjohQD0QuCPkL7BIVuAgHnPfXkI0C1LWh2pBwP9_NVhjj5HZxvc5IU_ronEpGnM-7Xv-7Vt4Wj3V7b_RPtXsn2jB4d7cOFb-nUEY3MPSkudwI8vU7i-MdNPVzcRfJa_Aaeuwo0</recordid><startdate>199703</startdate><enddate>199703</enddate><creator>Lee, Hongyo H.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199703</creationdate><title>Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead</title><author>Lee, Hongyo H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4306-e893b9100f0536d4a8f73af7eff18a47628a6fe75a7516b88213709fe66237b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Diseases of the cardiovascular system</topic><topic>Equipment Design</topic><topic>Equipment Safety</topic><topic>Female</topic><topic>Hemostasis, Surgical - instrumentation</topic><topic>Hemostasis, Surgical - methods</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Pacemaker, Artificial</topic><topic>peelaway sheath</topic><topic>peelaway sheath introducer with splittable hemostatic valve</topic><topic>permanent pacemaker implantation</topic><topic>permanent pacemaker lead</topic><topic>Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects)</topic><toplevel>online_resources</toplevel><creatorcontrib>Lee, Hongyo H.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Catheterization and cardiovascular diagnosis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lee, Hongyo H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead</atitle><jtitle>Catheterization and cardiovascular diagnosis</jtitle><addtitle>Cathet. Cardiovasc. Diagn</addtitle><date>1997-03</date><risdate>1997</risdate><volume>40</volume><issue>3</issue><spage>326</spage><epage>327</epage><pages>326-327</pages><issn>0098-6569</issn><eissn>1097-0304</eissn><coden>CCDIDC</coden><abstract>One hundred and twenty‐two permanent pacemaker lead placements were performed by two physicians, utilizing a recently released peelaway sheath introducer with a splittable hemostatic valve. All introducers performed well and provided convenient bloodless surgical fields, as expected from the presence of a valve. Cathet. Cardiovasc. Diagn. 40:326–327, 1997. © 1997 Wiley‐Liss Inc.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>9062736</pmid><doi>10.1002/(SICI)1097-0304(199703)40:3<326::AID-CCD26>3.0.CO;2-L</doi><tpages>2</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0098-6569 |
ispartof | Catheterization and cardiovascular diagnosis, 1997-03, Vol.40 (3), p.326-327 |
issn | 0098-6569 1097-0304 |
language | eng |
recordid | cdi_proquest_miscellaneous_78864593 |
source | Wiley |
subjects | Aged Biological and medical sciences Diseases of the cardiovascular system Equipment Design Equipment Safety Female Hemostasis, Surgical - instrumentation Hemostasis, Surgical - methods Humans Male Medical sciences Middle Aged Pacemaker, Artificial peelaway sheath peelaway sheath introducer with splittable hemostatic valve permanent pacemaker implantation permanent pacemaker lead Radiotherapy. Instrumental treatment. Physiotherapy. Reeducation. Rehabilitation, orthophony, crenotherapy. Diet therapy and various other treatments (general aspects) |
title | Usefulness of a peelaway sheath introducer with a splittable hemostatic valve for placement of permanent pacemaker lead |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T11%3A28%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Usefulness%20of%20a%20peelaway%20sheath%20introducer%20with%20a%20splittable%20hemostatic%20valve%20for%20placement%20of%20permanent%20pacemaker%20lead&rft.jtitle=Catheterization%20and%20cardiovascular%20diagnosis&rft.au=Lee,%20Hongyo%20H.&rft.date=1997-03&rft.volume=40&rft.issue=3&rft.spage=326&rft.epage=327&rft.pages=326-327&rft.issn=0098-6569&rft.eissn=1097-0304&rft.coden=CCDIDC&rft_id=info:doi/10.1002/(SICI)1097-0304(199703)40:3%3C326::AID-CCD26%3E3.0.CO;2-L&rft_dat=%3Cproquest_cross%3E78864593%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4306-e893b9100f0536d4a8f73af7eff18a47628a6fe75a7516b88213709fe66237b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=78864593&rft_id=info:pmid/9062736&rfr_iscdi=true |