Loading…

Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position

We report about a patient who underwent double valve replacement withtwo Starr-Edwards prostheses in aortic and mitral position 30 years ago.Under anticoagulation medication he survived 28 years without anyvalve-related events. In the 29th year he sustained a cerebral infarctionfrom which he recover...

Full description

Saved in:
Bibliographic Details
Published in:European journal of cardio-thoracic surgery 1997-02, Vol.11 (2), p.391-393
Main Authors: GÖDJE, O, BRENNER, P, FISCHLEIN, T, REICHART, B
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c494t-d22ba2158eae5bc1a14dba4b11bf6d0995c3fd96c480ee35c69632bda97d7e103
cites
container_end_page 393
container_issue 2
container_start_page 391
container_title European journal of cardio-thoracic surgery
container_volume 11
creator GÖDJE, O
BRENNER, P
FISCHLEIN, T
REICHART, B
description We report about a patient who underwent double valve replacement withtwo Starr-Edwards prostheses in aortic and mitral position 30 years ago.Under anticoagulation medication he survived 28 years without anyvalve-related events. In the 29th year he sustained a cerebral infarctionfrom which he recovered, having only a residual left arm paresis. His NYHAfunctional class today is II-III. Chest X-ray shows a mildly enlargedconfiguration of the heart, echocardiography reveals no irregularities ofthe implanted prostheses. We conclude, that the Starr- Edwards valvepresents an outstanding standard concerning durability in mechanical valvereplacement.
doi_str_mv 10.1016/S1010-7940(96)01064-0
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78889331</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1016/S1010-7940(96)01064-0</oup_id><sourcerecordid>78889331</sourcerecordid><originalsourceid>FETCH-LOGICAL-c494t-d22ba2158eae5bc1a14dba4b11bf6d0995c3fd96c480ee35c69632bda97d7e103</originalsourceid><addsrcrecordid>eNptkMtuFDEQRVsIFELgEyJ5gRAsDHY_7PYShoSAIrFIkEZsrGq7WmPoV2z3hPn7uDPDSEhs7JLr3Lqum2XnnL3njIsPN-lkVKqSvVXiXapFSdmT7JTXsqCyKNdPU_0XeZ69COEXY0wUuTzJThSrGZfVaTbdbpyPO7JD8IGE2W_dFjoCbURP7Dg3HZL0sEXicerAYI9DJPcubshNBO_phb0HbwOZ_BjiBgMG4gYCo4_OEBgs6V30aeI0BhfdOLzMnrXQBXx1uM-yH5cXt6srev39y9fVx2tqSlVGavO8gZxXNQJWjeHAS9tA2XDetMIypSpTtFYJU9YMsaiMUGm1xoKSViJnxVn2Zj83fexuxhB174LBroMBxzloWde1KgqewGoPmrRB8Njqybse_E5zppek9WPSeolRK6Efk9aLwfnBYG56tEfVIdrUf33oQzDQtR4G48IRy6taSrFgbI-N8_R_Z_qPM12c6V7iQsQ_RxH431rIQlb6av1Tr_jq07c1k_pz8QCjDKWw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78889331</pqid></control><display><type>article</type><title>Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position</title><source>Oxford Journals Online</source><creator>GÖDJE, O ; BRENNER, P ; FISCHLEIN, T ; REICHART, B</creator><creatorcontrib>GÖDJE, O ; BRENNER, P ; FISCHLEIN, T ; REICHART, B</creatorcontrib><description>We report about a patient who underwent double valve replacement withtwo Starr-Edwards prostheses in aortic and mitral position 30 years ago.Under anticoagulation medication he survived 28 years without anyvalve-related events. In the 29th year he sustained a cerebral infarctionfrom which he recovered, having only a residual left arm paresis. His NYHAfunctional class today is II-III. Chest X-ray shows a mildly enlargedconfiguration of the heart, echocardiography reveals no irregularities ofthe implanted prostheses. We conclude, that the Starr- Edwards valvepresents an outstanding standard concerning durability in mechanical valvereplacement.</description><identifier>ISSN: 1010-7940</identifier><identifier>EISSN: 1873-734X</identifier><identifier>DOI: 10.1016/S1010-7940(96)01064-0</identifier><identifier>PMID: 9080175</identifier><identifier>CODEN: EJCSE7</identifier><language>eng</language><publisher>Amsterdam: Elsevier Science B.V</publisher><subject>Adult ; Aortic Valve Insufficiency - diagnostic imaging ; Aortic Valve Insufficiency - surgery ; Biological and medical sciences ; Cerebral Infarction - diagnostic imaging ; Disease-Free Survival ; Echocardiography ; Follow-Up Studies ; Heart Valve Prosthesis ; Humans ; Male ; Medical sciences ; Mitral Valve Insufficiency - diagnostic imaging ; Mitral Valve Insufficiency - surgery ; Postoperative Complications - diagnostic imaging ; Prosthesis Design ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the heart</subject><ispartof>European journal of cardio-thoracic surgery, 1997-02, Vol.11 (2), p.391-393</ispartof><rights>1997 Elsevier Science B.V. 1997</rights><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c494t-d22ba2158eae5bc1a14dba4b11bf6d0995c3fd96c480ee35c69632bda97d7e103</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2587765$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9080175$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>GÖDJE, O</creatorcontrib><creatorcontrib>BRENNER, P</creatorcontrib><creatorcontrib>FISCHLEIN, T</creatorcontrib><creatorcontrib>REICHART, B</creatorcontrib><title>Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position</title><title>European journal of cardio-thoracic surgery</title><addtitle>Eur J Cardiothorac Surg</addtitle><addtitle>Eur J Cardiothorac Surg</addtitle><description>We report about a patient who underwent double valve replacement withtwo Starr-Edwards prostheses in aortic and mitral position 30 years ago.Under anticoagulation medication he survived 28 years without anyvalve-related events. In the 29th year he sustained a cerebral infarctionfrom which he recovered, having only a residual left arm paresis. His NYHAfunctional class today is II-III. Chest X-ray shows a mildly enlargedconfiguration of the heart, echocardiography reveals no irregularities ofthe implanted prostheses. We conclude, that the Starr- Edwards valvepresents an outstanding standard concerning durability in mechanical valvereplacement.</description><subject>Adult</subject><subject>Aortic Valve Insufficiency - diagnostic imaging</subject><subject>Aortic Valve Insufficiency - surgery</subject><subject>Biological and medical sciences</subject><subject>Cerebral Infarction - diagnostic imaging</subject><subject>Disease-Free Survival</subject><subject>Echocardiography</subject><subject>Follow-Up Studies</subject><subject>Heart Valve Prosthesis</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Mitral Valve Insufficiency - diagnostic imaging</subject><subject>Mitral Valve Insufficiency - surgery</subject><subject>Postoperative Complications - diagnostic imaging</subject><subject>Prosthesis Design</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the heart</subject><issn>1010-7940</issn><issn>1873-734X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNptkMtuFDEQRVsIFELgEyJ5gRAsDHY_7PYShoSAIrFIkEZsrGq7WmPoV2z3hPn7uDPDSEhs7JLr3Lqum2XnnL3njIsPN-lkVKqSvVXiXapFSdmT7JTXsqCyKNdPU_0XeZ69COEXY0wUuTzJThSrGZfVaTbdbpyPO7JD8IGE2W_dFjoCbURP7Dg3HZL0sEXicerAYI9DJPcubshNBO_phb0HbwOZ_BjiBgMG4gYCo4_OEBgs6V30aeI0BhfdOLzMnrXQBXx1uM-yH5cXt6srev39y9fVx2tqSlVGavO8gZxXNQJWjeHAS9tA2XDetMIypSpTtFYJU9YMsaiMUGm1xoKSViJnxVn2Zj83fexuxhB174LBroMBxzloWde1KgqewGoPmrRB8Njqybse_E5zppek9WPSeolRK6Efk9aLwfnBYG56tEfVIdrUf33oQzDQtR4G48IRy6taSrFgbI-N8_R_Z_qPM12c6V7iQsQ_RxH431rIQlb6av1Tr_jq07c1k_pz8QCjDKWw</recordid><startdate>19970201</startdate><enddate>19970201</enddate><creator>GÖDJE, O</creator><creator>BRENNER, P</creator><creator>FISCHLEIN, T</creator><creator>REICHART, B</creator><general>Elsevier Science B.V</general><general>Elsevier Science</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19970201</creationdate><title>Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position</title><author>GÖDJE, O ; BRENNER, P ; FISCHLEIN, T ; REICHART, B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c494t-d22ba2158eae5bc1a14dba4b11bf6d0995c3fd96c480ee35c69632bda97d7e103</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Adult</topic><topic>Aortic Valve Insufficiency - diagnostic imaging</topic><topic>Aortic Valve Insufficiency - surgery</topic><topic>Biological and medical sciences</topic><topic>Cerebral Infarction - diagnostic imaging</topic><topic>Disease-Free Survival</topic><topic>Echocardiography</topic><topic>Follow-Up Studies</topic><topic>Heart Valve Prosthesis</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Mitral Valve Insufficiency - diagnostic imaging</topic><topic>Mitral Valve Insufficiency - surgery</topic><topic>Postoperative Complications - diagnostic imaging</topic><topic>Prosthesis Design</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the heart</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GÖDJE, O</creatorcontrib><creatorcontrib>BRENNER, P</creatorcontrib><creatorcontrib>FISCHLEIN, T</creatorcontrib><creatorcontrib>REICHART, B</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of cardio-thoracic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GÖDJE, O</au><au>BRENNER, P</au><au>FISCHLEIN, T</au><au>REICHART, B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position</atitle><jtitle>European journal of cardio-thoracic surgery</jtitle><stitle>Eur J Cardiothorac Surg</stitle><addtitle>Eur J Cardiothorac Surg</addtitle><date>1997-02-01</date><risdate>1997</risdate><volume>11</volume><issue>2</issue><spage>391</spage><epage>393</epage><pages>391-393</pages><issn>1010-7940</issn><eissn>1873-734X</eissn><coden>EJCSE7</coden><abstract>We report about a patient who underwent double valve replacement withtwo Starr-Edwards prostheses in aortic and mitral position 30 years ago.Under anticoagulation medication he survived 28 years without anyvalve-related events. In the 29th year he sustained a cerebral infarctionfrom which he recovered, having only a residual left arm paresis. His NYHAfunctional class today is II-III. Chest X-ray shows a mildly enlargedconfiguration of the heart, echocardiography reveals no irregularities ofthe implanted prostheses. We conclude, that the Starr- Edwards valvepresents an outstanding standard concerning durability in mechanical valvereplacement.</abstract><cop>Amsterdam</cop><pub>Elsevier Science B.V</pub><pmid>9080175</pmid><doi>10.1016/S1010-7940(96)01064-0</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1010-7940
ispartof European journal of cardio-thoracic surgery, 1997-02, Vol.11 (2), p.391-393
issn 1010-7940
1873-734X
language eng
recordid cdi_proquest_miscellaneous_78889331
source Oxford Journals Online
subjects Adult
Aortic Valve Insufficiency - diagnostic imaging
Aortic Valve Insufficiency - surgery
Biological and medical sciences
Cerebral Infarction - diagnostic imaging
Disease-Free Survival
Echocardiography
Follow-Up Studies
Heart Valve Prosthesis
Humans
Male
Medical sciences
Mitral Valve Insufficiency - diagnostic imaging
Mitral Valve Insufficiency - surgery
Postoperative Complications - diagnostic imaging
Prosthesis Design
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the heart
title Thirty years survival after double valve replacement with Starr-Edwards prostheses in aortic and mitral position
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T09%3A54%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Thirty%20years%20survival%20after%20double%20valve%20replacement%20with%20Starr-Edwards%20prostheses%20in%20aortic%20and%20mitral%20position&rft.jtitle=European%20journal%20of%20cardio-thoracic%20surgery&rft.au=G%C3%96DJE,%20O&rft.date=1997-02-01&rft.volume=11&rft.issue=2&rft.spage=391&rft.epage=393&rft.pages=391-393&rft.issn=1010-7940&rft.eissn=1873-734X&rft.coden=EJCSE7&rft_id=info:doi/10.1016/S1010-7940(96)01064-0&rft_dat=%3Cproquest_cross%3E78889331%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c494t-d22ba2158eae5bc1a14dba4b11bf6d0995c3fd96c480ee35c69632bda97d7e103%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=78889331&rft_id=info:pmid/9080175&rft_oup_id=10.1016/S1010-7940(96)01064-0&rfr_iscdi=true