A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat

A stepper motor-powered micropump for making intracerebral microinjections in freely moving animals is described. The micropump is capable of delivering fluid volumes of up to 20 μl in steps of 17 nl The system does not require a fluid swivel, delivers injections rapidly, maintains long-term calibra...

Full description

Saved in:
Bibliographic Details
Published in:Journal of neuroscience methods 1997-03, Vol.72 (1), p.35-38
Main Authors: Hesse, Gary W, Stellar, James R, Chevrette, Jessica
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323
cites cdi_FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323
container_end_page 38
container_issue 1
container_start_page 35
container_title Journal of neuroscience methods
container_volume 72
creator Hesse, Gary W
Stellar, James R
Chevrette, Jessica
description A stepper motor-powered micropump for making intracerebral microinjections in freely moving animals is described. The micropump is capable of delivering fluid volumes of up to 20 μl in steps of 17 nl The system does not require a fluid swivel, delivers injections rapidly, maintains long-term calibration accuracy and is not susceptible to blockage of the cannula.
doi_str_mv 10.1016/S0165-0270(96)00152-5
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78937538</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0165027096001525</els_id><sourcerecordid>78937538</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323</originalsourceid><addsrcrecordid>eNqFkU-PFCEQxYnRrOPqR9iEgzF6aC3oBpqT2Wz8l2ziQU28ERoKF0M3I3RPst_e7p3JXPcCgferoniPkCsG7xkw-eHHuogGuIK3Wr4DYII34gnZsV7xRqr-91OyOyPPyYta_wJAp0FekAvNeL9qO-KuaY3jPiG1k6cFU7TDehhxvsuehlyoX-8OWOL0h9bRpkRDWqKnh5yWESudM53vkA7FxonmQC0NBTHd0zEftppi55fkWbCp4qvTfkl-ff708-Zrc_v9y7eb69vGdRzmRujBMye8Zc4LHrgYvJQK5NC10CqvhQfnoZMcMXirVTdAr1rrGYT1Oy1vL8mbY999yf8WrLMZY3WYkp0wL9WoXrdKtP2jIJNdJxgTKyiOoCu51oLB7Escbbk3DMyWgnlIwWwWGy3NQwpmq7s6PbAMI_pz1cn2VX990m11NoViJxfrGeOSa8G3OT8eMVxdO0QsprqIk0MfC7rZ-BwfGeQ_o5-jMg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>16445115</pqid></control><display><type>article</type><title>A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat</title><source>Elsevier</source><creator>Hesse, Gary W ; Stellar, James R ; Chevrette, Jessica</creator><creatorcontrib>Hesse, Gary W ; Stellar, James R ; Chevrette, Jessica</creatorcontrib><description>A stepper motor-powered micropump for making intracerebral microinjections in freely moving animals is described. The micropump is capable of delivering fluid volumes of up to 20 μl in steps of 17 nl The system does not require a fluid swivel, delivers injections rapidly, maintains long-term calibration accuracy and is not susceptible to blockage of the cannula.</description><identifier>ISSN: 0165-0270</identifier><identifier>EISSN: 1872-678X</identifier><identifier>DOI: 10.1016/S0165-0270(96)00152-5</identifier><identifier>PMID: 9128165</identifier><identifier>CODEN: JNMEDT</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Animals ; Biological and medical sciences ; Brain - physiology ; Fundamental and applied biological sciences. Psychology ; General aspects. Models. Methods ; Infusion Pumps ; Intracranial Injection ; Locomotion - physiology ; Microinjection ; Microinjections - instrumentation ; Microinjections - methods ; Micropump ; Rats ; Vertebrates: nervous system and sense organs</subject><ispartof>Journal of neuroscience methods, 1997-03, Vol.72 (1), p.35-38</ispartof><rights>1997 Elsevier Science B.V.</rights><rights>1997 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323</citedby><cites>FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2629528$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9128165$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hesse, Gary W</creatorcontrib><creatorcontrib>Stellar, James R</creatorcontrib><creatorcontrib>Chevrette, Jessica</creatorcontrib><title>A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat</title><title>Journal of neuroscience methods</title><addtitle>J Neurosci Methods</addtitle><description>A stepper motor-powered micropump for making intracerebral microinjections in freely moving animals is described. The micropump is capable of delivering fluid volumes of up to 20 μl in steps of 17 nl The system does not require a fluid swivel, delivers injections rapidly, maintains long-term calibration accuracy and is not susceptible to blockage of the cannula.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Brain - physiology</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>General aspects. Models. Methods</subject><subject>Infusion Pumps</subject><subject>Intracranial Injection</subject><subject>Locomotion - physiology</subject><subject>Microinjection</subject><subject>Microinjections - instrumentation</subject><subject>Microinjections - methods</subject><subject>Micropump</subject><subject>Rats</subject><subject>Vertebrates: nervous system and sense organs</subject><issn>0165-0270</issn><issn>1872-678X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkU-PFCEQxYnRrOPqR9iEgzF6aC3oBpqT2Wz8l2ziQU28ERoKF0M3I3RPst_e7p3JXPcCgferoniPkCsG7xkw-eHHuogGuIK3Wr4DYII34gnZsV7xRqr-91OyOyPPyYta_wJAp0FekAvNeL9qO-KuaY3jPiG1k6cFU7TDehhxvsuehlyoX-8OWOL0h9bRpkRDWqKnh5yWESudM53vkA7FxonmQC0NBTHd0zEftppi55fkWbCp4qvTfkl-ff708-Zrc_v9y7eb69vGdRzmRujBMye8Zc4LHrgYvJQK5NC10CqvhQfnoZMcMXirVTdAr1rrGYT1Oy1vL8mbY999yf8WrLMZY3WYkp0wL9WoXrdKtP2jIJNdJxgTKyiOoCu51oLB7Escbbk3DMyWgnlIwWwWGy3NQwpmq7s6PbAMI_pz1cn2VX990m11NoViJxfrGeOSa8G3OT8eMVxdO0QsprqIk0MfC7rZ-BwfGeQ_o5-jMg</recordid><startdate>19970301</startdate><enddate>19970301</enddate><creator>Hesse, Gary W</creator><creator>Stellar, James R</creator><creator>Chevrette, Jessica</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>7X8</scope></search><sort><creationdate>19970301</creationdate><title>A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat</title><author>Hesse, Gary W ; Stellar, James R ; Chevrette, Jessica</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Brain - physiology</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>General aspects. Models. Methods</topic><topic>Infusion Pumps</topic><topic>Intracranial Injection</topic><topic>Locomotion - physiology</topic><topic>Microinjection</topic><topic>Microinjections - instrumentation</topic><topic>Microinjections - methods</topic><topic>Micropump</topic><topic>Rats</topic><topic>Vertebrates: nervous system and sense organs</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hesse, Gary W</creatorcontrib><creatorcontrib>Stellar, James R</creatorcontrib><creatorcontrib>Chevrette, Jessica</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of neuroscience methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hesse, Gary W</au><au>Stellar, James R</au><au>Chevrette, Jessica</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat</atitle><jtitle>Journal of neuroscience methods</jtitle><addtitle>J Neurosci Methods</addtitle><date>1997-03-01</date><risdate>1997</risdate><volume>72</volume><issue>1</issue><spage>35</spage><epage>38</epage><pages>35-38</pages><issn>0165-0270</issn><eissn>1872-678X</eissn><coden>JNMEDT</coden><abstract>A stepper motor-powered micropump for making intracerebral microinjections in freely moving animals is described. The micropump is capable of delivering fluid volumes of up to 20 μl in steps of 17 nl The system does not require a fluid swivel, delivers injections rapidly, maintains long-term calibration accuracy and is not susceptible to blockage of the cannula.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>9128165</pmid><doi>10.1016/S0165-0270(96)00152-5</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0165-0270
ispartof Journal of neuroscience methods, 1997-03, Vol.72 (1), p.35-38
issn 0165-0270
1872-678X
language eng
recordid cdi_proquest_miscellaneous_78937538
source Elsevier
subjects Animals
Biological and medical sciences
Brain - physiology
Fundamental and applied biological sciences. Psychology
General aspects. Models. Methods
Infusion Pumps
Intracranial Injection
Locomotion - physiology
Microinjection
Microinjections - instrumentation
Microinjections - methods
Micropump
Rats
Vertebrates: nervous system and sense organs
title A simple and reliable method for delivering small fluid volumes to the brain of a freely moving rat
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T21%3A07%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20simple%20and%20reliable%20method%20for%20delivering%20small%20fluid%20volumes%20to%20the%20brain%20of%20a%20freely%20moving%20rat&rft.jtitle=Journal%20of%20neuroscience%20methods&rft.au=Hesse,%20Gary%20W&rft.date=1997-03-01&rft.volume=72&rft.issue=1&rft.spage=35&rft.epage=38&rft.pages=35-38&rft.issn=0165-0270&rft.eissn=1872-678X&rft.coden=JNMEDT&rft_id=info:doi/10.1016/S0165-0270(96)00152-5&rft_dat=%3Cproquest_cross%3E78937538%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-59bd1c5da1cd52f25bd66706b43037d95d0cd0462eefda974b0873ad10f912323%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=16445115&rft_id=info:pmid/9128165&rfr_iscdi=true