Loading…

High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma

A high-performance liquid chromatographic (HPLC) method was developed for the combined analysis of the chemoprotective agent, amifostine, its active metabolite, WR 1065, and the (symmetrical and mixed) disulfides of WR 1065 in plasma. These three compounds were quantified by measuring WR 1065 after...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Biomedical sciences and applications Biomedical sciences and applications, 1997-05, Vol.693 (1), p.167-174
Main Authors: Korst, A.E.C, Vermorken, J.B, van der Vijgh, W.J.F
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373
cites cdi_FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373
container_end_page 174
container_issue 1
container_start_page 167
container_title Journal of chromatography. B, Biomedical sciences and applications
container_volume 693
creator Korst, A.E.C
Vermorken, J.B
van der Vijgh, W.J.F
description A high-performance liquid chromatographic (HPLC) method was developed for the combined analysis of the chemoprotective agent, amifostine, its active metabolite, WR 1065, and the (symmetrical and mixed) disulfides of WR 1065 in plasma. These three compounds were quantified by measuring WR 1065 after three different sample pretreatment procedures. During these procedures, amifostine and the disulfides were quantitatively converted into WR 1065, by incubating the sample either at a low pH or in the presence of dithiothreitol, respectively. The resulting amounts of WR 1065 were determined by HPLC with electrochemical detection (Au electrode, +1.00 V). The lower limit of quantitation of WR 1065 was 0.15 μ M. The within-day and between-day precision were ≤4.4 and ≤8.2% for WR 1065, ≤4.9 and ≤13.1% for amifostine and ≤8.5 and ≤5.5% for the disulfides, respectively. The within-day and between-day accuracy ranged from 97.2 to 109.8% and from 97.6 to 101.5% for WR 1065, from 88.3 to 110.7% and from 99.4 to 101.5% for amifostine and from 99.2 to 110.2% and from 103.3 to 104.9% for the disulfides, respectively. This method is superior to other described methods due to its simple and relatively rapid analysis of all three compounds in one system. Furthermore, it is at least as sensitive as earlier reported methods for one of the compounds and the application of the gold electrode requires only minor maintenance. Therefore, this method is very suitable for pharmacokinetic studies of amifostine and its metabolites. As an example, the plasma concentrations of amifostine, WR 1065 and the disulfides are shown in a patient after receiving an i.v. dose of 740 mg/m 2 amifostine.
doi_str_mv 10.1016/S0378-4347(97)00016-9
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_79080475</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378434797000169</els_id><sourcerecordid>79080475</sourcerecordid><originalsourceid>FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373</originalsourceid><addsrcrecordid>eNqFkc2KFDEQx_ugrOvqIyzkIKKwrZXO9KRzEll0V1gQ_MBjqEmqp0s6ndmkW9iX8VnNzgxz9RT4f1SK-lXVpYR3EuT6_XdQuqtXaqXfGP0WoGi1eVKdn-Rn1fOcfwOoFTTNWXVmGoBWyfPq7y1vh3pHqY8p4ORIjHy_sBduSDHgHLcJdwM7gTnjg1gyT1tBI7k5RTdQYIej8DQXgeMkyhQxDyRcDBueyItAmJdEgaZZxF5g4D7muVhX4tc3IWHdCpz8vuM5L2PPnrLgSexGzAFfVE97HDO9PL4X1c_Pn35c39Z3X2--XH-8q53qzFyTJqcl9UZ70Mr1RipcIxhFpnPotTfOg-8I0KtO6o3ytPFOG916ko3S6qJ6fZi7S_F-oTzbwNnROOJEcclWG-hgpdsSbA9Bl2LOiXq7SxwwPVgJ9pGF3bOwj0e3Rts9C2tK7_L4wbIJ5E-tI4jivzr6mMtJ-1RYcD7FGq1AgiqxD4cYlWP8YUo2O6aCzXMqCKyP_J9F_gFNx6uW</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79080475</pqid></control><display><type>article</type><title>High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma</title><source>ScienceDirect Freedom Collection</source><creator>Korst, A.E.C ; Vermorken, J.B ; van der Vijgh, W.J.F</creator><creatorcontrib>Korst, A.E.C ; Vermorken, J.B ; van der Vijgh, W.J.F</creatorcontrib><description>A high-performance liquid chromatographic (HPLC) method was developed for the combined analysis of the chemoprotective agent, amifostine, its active metabolite, WR 1065, and the (symmetrical and mixed) disulfides of WR 1065 in plasma. These three compounds were quantified by measuring WR 1065 after three different sample pretreatment procedures. During these procedures, amifostine and the disulfides were quantitatively converted into WR 1065, by incubating the sample either at a low pH or in the presence of dithiothreitol, respectively. The resulting amounts of WR 1065 were determined by HPLC with electrochemical detection (Au electrode, +1.00 V). The lower limit of quantitation of WR 1065 was 0.15 μ M. The within-day and between-day precision were ≤4.4 and ≤8.2% for WR 1065, ≤4.9 and ≤13.1% for amifostine and ≤8.5 and ≤5.5% for the disulfides, respectively. The within-day and between-day accuracy ranged from 97.2 to 109.8% and from 97.6 to 101.5% for WR 1065, from 88.3 to 110.7% and from 99.4 to 101.5% for amifostine and from 99.2 to 110.2% and from 103.3 to 104.9% for the disulfides, respectively. This method is superior to other described methods due to its simple and relatively rapid analysis of all three compounds in one system. Furthermore, it is at least as sensitive as earlier reported methods for one of the compounds and the application of the gold electrode requires only minor maintenance. Therefore, this method is very suitable for pharmacokinetic studies of amifostine and its metabolites. As an example, the plasma concentrations of amifostine, WR 1065 and the disulfides are shown in a patient after receiving an i.v. dose of 740 mg/m 2 amifostine.</description><identifier>ISSN: 0378-4347</identifier><identifier>ISSN: 1387-2273</identifier><identifier>DOI: 10.1016/S0378-4347(97)00016-9</identifier><identifier>PMID: 9200531</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Amifostine ; Amifostine - analysis ; Analysis ; Biological and medical sciences ; Chromatography, High Pressure Liquid ; Disulfides - blood ; Electrochemistry ; General pharmacology ; Humans ; Medical sciences ; Mercaptoethylamines - blood ; Pharmacology. Drug treatments ; Radiation-Protective Agents - analysis ; Reproducibility of Results ; WR 1065</subject><ispartof>Journal of chromatography. B, Biomedical sciences and applications, 1997-05, Vol.693 (1), p.167-174</ispartof><rights>1997 Elsevier Science B.V.</rights><rights>1997 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373</citedby><cites>FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2730103$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9200531$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Korst, A.E.C</creatorcontrib><creatorcontrib>Vermorken, J.B</creatorcontrib><creatorcontrib>van der Vijgh, W.J.F</creatorcontrib><title>High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma</title><title>Journal of chromatography. B, Biomedical sciences and applications</title><addtitle>J Chromatogr B Biomed Sci Appl</addtitle><description>A high-performance liquid chromatographic (HPLC) method was developed for the combined analysis of the chemoprotective agent, amifostine, its active metabolite, WR 1065, and the (symmetrical and mixed) disulfides of WR 1065 in plasma. These three compounds were quantified by measuring WR 1065 after three different sample pretreatment procedures. During these procedures, amifostine and the disulfides were quantitatively converted into WR 1065, by incubating the sample either at a low pH or in the presence of dithiothreitol, respectively. The resulting amounts of WR 1065 were determined by HPLC with electrochemical detection (Au electrode, +1.00 V). The lower limit of quantitation of WR 1065 was 0.15 μ M. The within-day and between-day precision were ≤4.4 and ≤8.2% for WR 1065, ≤4.9 and ≤13.1% for amifostine and ≤8.5 and ≤5.5% for the disulfides, respectively. The within-day and between-day accuracy ranged from 97.2 to 109.8% and from 97.6 to 101.5% for WR 1065, from 88.3 to 110.7% and from 99.4 to 101.5% for amifostine and from 99.2 to 110.2% and from 103.3 to 104.9% for the disulfides, respectively. This method is superior to other described methods due to its simple and relatively rapid analysis of all three compounds in one system. Furthermore, it is at least as sensitive as earlier reported methods for one of the compounds and the application of the gold electrode requires only minor maintenance. Therefore, this method is very suitable for pharmacokinetic studies of amifostine and its metabolites. As an example, the plasma concentrations of amifostine, WR 1065 and the disulfides are shown in a patient after receiving an i.v. dose of 740 mg/m 2 amifostine.</description><subject>Amifostine</subject><subject>Amifostine - analysis</subject><subject>Analysis</subject><subject>Biological and medical sciences</subject><subject>Chromatography, High Pressure Liquid</subject><subject>Disulfides - blood</subject><subject>Electrochemistry</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Mercaptoethylamines - blood</subject><subject>Pharmacology. Drug treatments</subject><subject>Radiation-Protective Agents - analysis</subject><subject>Reproducibility of Results</subject><subject>WR 1065</subject><issn>0378-4347</issn><issn>1387-2273</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkc2KFDEQx_ugrOvqIyzkIKKwrZXO9KRzEll0V1gQ_MBjqEmqp0s6ndmkW9iX8VnNzgxz9RT4f1SK-lXVpYR3EuT6_XdQuqtXaqXfGP0WoGi1eVKdn-Rn1fOcfwOoFTTNWXVmGoBWyfPq7y1vh3pHqY8p4ORIjHy_sBduSDHgHLcJdwM7gTnjg1gyT1tBI7k5RTdQYIej8DQXgeMkyhQxDyRcDBueyItAmJdEgaZZxF5g4D7muVhX4tc3IWHdCpz8vuM5L2PPnrLgSexGzAFfVE97HDO9PL4X1c_Pn35c39Z3X2--XH-8q53qzFyTJqcl9UZ70Mr1RipcIxhFpnPotTfOg-8I0KtO6o3ytPFOG916ko3S6qJ6fZi7S_F-oTzbwNnROOJEcclWG-hgpdsSbA9Bl2LOiXq7SxwwPVgJ9pGF3bOwj0e3Rts9C2tK7_L4wbIJ5E-tI4jivzr6mMtJ-1RYcD7FGq1AgiqxD4cYlWP8YUo2O6aCzXMqCKyP_J9F_gFNx6uW</recordid><startdate>19970523</startdate><enddate>19970523</enddate><creator>Korst, A.E.C</creator><creator>Vermorken, J.B</creator><creator>van der Vijgh, W.J.F</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19970523</creationdate><title>High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma</title><author>Korst, A.E.C ; Vermorken, J.B ; van der Vijgh, W.J.F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Amifostine</topic><topic>Amifostine - analysis</topic><topic>Analysis</topic><topic>Biological and medical sciences</topic><topic>Chromatography, High Pressure Liquid</topic><topic>Disulfides - blood</topic><topic>Electrochemistry</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Mercaptoethylamines - blood</topic><topic>Pharmacology. Drug treatments</topic><topic>Radiation-Protective Agents - analysis</topic><topic>Reproducibility of Results</topic><topic>WR 1065</topic><toplevel>online_resources</toplevel><creatorcontrib>Korst, A.E.C</creatorcontrib><creatorcontrib>Vermorken, J.B</creatorcontrib><creatorcontrib>van der Vijgh, W.J.F</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatography. B, Biomedical sciences and applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Korst, A.E.C</au><au>Vermorken, J.B</au><au>van der Vijgh, W.J.F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma</atitle><jtitle>Journal of chromatography. B, Biomedical sciences and applications</jtitle><addtitle>J Chromatogr B Biomed Sci Appl</addtitle><date>1997-05-23</date><risdate>1997</risdate><volume>693</volume><issue>1</issue><spage>167</spage><epage>174</epage><pages>167-174</pages><issn>0378-4347</issn><issn>1387-2273</issn><abstract>A high-performance liquid chromatographic (HPLC) method was developed for the combined analysis of the chemoprotective agent, amifostine, its active metabolite, WR 1065, and the (symmetrical and mixed) disulfides of WR 1065 in plasma. These three compounds were quantified by measuring WR 1065 after three different sample pretreatment procedures. During these procedures, amifostine and the disulfides were quantitatively converted into WR 1065, by incubating the sample either at a low pH or in the presence of dithiothreitol, respectively. The resulting amounts of WR 1065 were determined by HPLC with electrochemical detection (Au electrode, +1.00 V). The lower limit of quantitation of WR 1065 was 0.15 μ M. The within-day and between-day precision were ≤4.4 and ≤8.2% for WR 1065, ≤4.9 and ≤13.1% for amifostine and ≤8.5 and ≤5.5% for the disulfides, respectively. The within-day and between-day accuracy ranged from 97.2 to 109.8% and from 97.6 to 101.5% for WR 1065, from 88.3 to 110.7% and from 99.4 to 101.5% for amifostine and from 99.2 to 110.2% and from 103.3 to 104.9% for the disulfides, respectively. This method is superior to other described methods due to its simple and relatively rapid analysis of all three compounds in one system. Furthermore, it is at least as sensitive as earlier reported methods for one of the compounds and the application of the gold electrode requires only minor maintenance. Therefore, this method is very suitable for pharmacokinetic studies of amifostine and its metabolites. As an example, the plasma concentrations of amifostine, WR 1065 and the disulfides are shown in a patient after receiving an i.v. dose of 740 mg/m 2 amifostine.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>9200531</pmid><doi>10.1016/S0378-4347(97)00016-9</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-4347
ispartof Journal of chromatography. B, Biomedical sciences and applications, 1997-05, Vol.693 (1), p.167-174
issn 0378-4347
1387-2273
language eng
recordid cdi_proquest_miscellaneous_79080475
source ScienceDirect Freedom Collection
subjects Amifostine
Amifostine - analysis
Analysis
Biological and medical sciences
Chromatography, High Pressure Liquid
Disulfides - blood
Electrochemistry
General pharmacology
Humans
Medical sciences
Mercaptoethylamines - blood
Pharmacology. Drug treatments
Radiation-Protective Agents - analysis
Reproducibility of Results
WR 1065
title High-performance liquid chromatographic assay using electrochemical detection for the combined measurement of amifostine, WR 1065 and the disulfides in plasma
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T18%3A27%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-performance%20liquid%20chromatographic%20assay%20using%20electrochemical%20detection%20for%20the%20combined%20measurement%20of%20amifostine,%20WR%201065%20and%20the%20disulfides%20in%20plasma&rft.jtitle=Journal%20of%20chromatography.%20B,%20Biomedical%20sciences%20and%20applications&rft.au=Korst,%20A.E.C&rft.date=1997-05-23&rft.volume=693&rft.issue=1&rft.spage=167&rft.epage=174&rft.pages=167-174&rft.issn=0378-4347&rft_id=info:doi/10.1016/S0378-4347(97)00016-9&rft_dat=%3Cproquest_cross%3E79080475%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c389t-e7ec71ef97d073cf913a6a093e98cad7d9cd0d8e0ad3817b3debdc7975de12373%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=79080475&rft_id=info:pmid/9200531&rfr_iscdi=true