Validation of an LC-MS assay for the quantification of the enantiomers of Org 4428 in human plasma
A sensitive and selective liquid chromatographic mass spectrometric assay has been validated for the quantification of Org 4428 enantiomers in human plasma. The assay employs n-hexane extraction from alkalinized plasma, separation on a narrow-bore enantioselective normal phase Chiralpak AD column an...
Saved in:
Published in: | Journal of pharmaceutical and biomedical analysis 1998-02, Vol.16 (6), p.981-989 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A sensitive and selective liquid chromatographic mass spectrometric assay has been validated for the quantification of Org 4428 enantiomers in human plasma. The assay employs
n-hexane extraction from alkalinized plasma, separation on a narrow-bore enantioselective normal phase Chiralpak AD column and APCI MS-MS detection. The lower limit of quantification is 0.5 ng ml
−1 plasma for the individual enantiomers. |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/S0731-7085(97)00113-1 |