Loading…

Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers

A suitable procedure was developed for speciation analysis of metalloprotein complexes in serum using directly coupled size-exclusion chromatography and an element-specific detector. Two column matrices used for size-exclusion chromatography (TSK G 3000 SW and Asahipak GS 520) were investigated with...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. B, Biomedical sciences and applications Biomedical sciences and applications, 1998-04, Vol.707 (1), p.17-24
Main Authors: Raab, Andrea, Brätter, Peter
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 24
container_issue 1
container_start_page 17
container_title Journal of chromatography. B, Biomedical sciences and applications
container_volume 707
creator Raab, Andrea
Brätter, Peter
description A suitable procedure was developed for speciation analysis of metalloprotein complexes in serum using directly coupled size-exclusion chromatography and an element-specific detector. Two column matrices used for size-exclusion chromatography (TSK G 3000 SW and Asahipak GS 520) were investigated with respect to the recovery and retention behaviour for metalloprotein complexes. Optimisation of the separation parameters (buffer type, concentration, pH) was achieved by means of metalloprotein complexes marked with radiotracers. For speciation of serum the matrix in the Asahipak GS column is more efficient. Given optimal eluent characteristics (100 m M Tris, pH 7.4) the recovery of the elements investigated (sodium, calcium, iron and zinc) was 100%. Further, the retention behaviour (retention time, ratios of the peak areas) remained unchanged for several successive separations.
doi_str_mv 10.1016/S0378-4347(97)00613-0
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_79906692</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378434797006130</els_id><sourcerecordid>79906692</sourcerecordid><originalsourceid>FETCH-LOGICAL-e291t-ec11ea984ce7b8528827187208c5814b200d1a2d52bce145601259ad5b2a9f03</originalsourceid><addsrcrecordid>eNo9Uc1O3DAQ9oEKKPAISD5UqBxSbOfP5lIhVCgSEge4WxNnljVK4tR2VoTX4gXrLKs9jT3z_WjmI-Scs1-c8erqmeW1zIq8qH-q-pKxiucZOyDH-_YR-R7CG2N5wYQ4JIcqIZRQx-TzGUfwEK0bqFvRHiN0nRu9i2gHalw_dviOgaZPQD_1tJlpsB-Y4bvpprDQzNq7HqJ79TCu52v6NEbb27DXjGtM3L3L8kg26AP1qQzbZoNr2Fg3eQpDm_rGbdDPFJO9m-3wSj201kUPJvFOybcVdAHPdvWEvNz9ebn9mz0-3T_c3jxmKBSPGRrOEZQsDNaNLIWUouayFkyaUvKiEYy1HERbisYgL8qKcVEqaMtGgFqx_IRcfMmma_ybMESdtjLYdTCgm4KulWJVpUQCnu-AU9Njq0dve_Cz3h05zX_s5hAMdCsPg7FhDxNCFKVcZH5_wTDttLHodTAWB4OtTQeJunVWc6aXwPU2cL0kq1Wtt4Frlv8HwjGkYg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>79906692</pqid></control><display><type>article</type><title>Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers</title><source>Elsevier</source><creator>Raab, Andrea ; Brätter, Peter</creator><creatorcontrib>Raab, Andrea ; Brätter, Peter</creatorcontrib><description>A suitable procedure was developed for speciation analysis of metalloprotein complexes in serum using directly coupled size-exclusion chromatography and an element-specific detector. Two column matrices used for size-exclusion chromatography (TSK G 3000 SW and Asahipak GS 520) were investigated with respect to the recovery and retention behaviour for metalloprotein complexes. Optimisation of the separation parameters (buffer type, concentration, pH) was achieved by means of metalloprotein complexes marked with radiotracers. For speciation of serum the matrix in the Asahipak GS column is more efficient. Given optimal eluent characteristics (100 m M Tris, pH 7.4) the recovery of the elements investigated (sodium, calcium, iron and zinc) was 100%. Further, the retention behaviour (retention time, ratios of the peak areas) remained unchanged for several successive separations.</description><identifier>ISSN: 0378-4347</identifier><identifier>ISSN: 1387-2273</identifier><identifier>DOI: 10.1016/S0378-4347(97)00613-0</identifier><identifier>PMID: 9613929</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical, structural and metabolic biochemistry ; Biological and medical sciences ; Buffers ; Calcium - blood ; Calcium - isolation &amp; purification ; Chromatography, Gel ; Fundamental and applied biological sciences. Psychology ; Humans ; Hydrogen-Ion Concentration ; Indicators and Reagents ; Metalloprotein ; Metalloproteins ; Metalloproteins - blood ; Metalloproteins - isolation &amp; purification ; Other metalloproteins ; Proteins ; Silicon Dioxide ; Sodium - blood ; Sodium - isolation &amp; purification ; Spectrophotometry, Ultraviolet ; Zinc - blood ; Zinc - isolation &amp; purification</subject><ispartof>Journal of chromatography. B, Biomedical sciences and applications, 1998-04, Vol.707 (1), p.17-24</ispartof><rights>1998 Elsevier Science B.V.</rights><rights>1998 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2224582$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9613929$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Raab, Andrea</creatorcontrib><creatorcontrib>Brätter, Peter</creatorcontrib><title>Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers</title><title>Journal of chromatography. B, Biomedical sciences and applications</title><addtitle>J Chromatogr B Biomed Sci Appl</addtitle><description>A suitable procedure was developed for speciation analysis of metalloprotein complexes in serum using directly coupled size-exclusion chromatography and an element-specific detector. Two column matrices used for size-exclusion chromatography (TSK G 3000 SW and Asahipak GS 520) were investigated with respect to the recovery and retention behaviour for metalloprotein complexes. Optimisation of the separation parameters (buffer type, concentration, pH) was achieved by means of metalloprotein complexes marked with radiotracers. For speciation of serum the matrix in the Asahipak GS column is more efficient. Given optimal eluent characteristics (100 m M Tris, pH 7.4) the recovery of the elements investigated (sodium, calcium, iron and zinc) was 100%. Further, the retention behaviour (retention time, ratios of the peak areas) remained unchanged for several successive separations.</description><subject>Analytical, structural and metabolic biochemistry</subject><subject>Biological and medical sciences</subject><subject>Buffers</subject><subject>Calcium - blood</subject><subject>Calcium - isolation &amp; purification</subject><subject>Chromatography, Gel</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Humans</subject><subject>Hydrogen-Ion Concentration</subject><subject>Indicators and Reagents</subject><subject>Metalloprotein</subject><subject>Metalloproteins</subject><subject>Metalloproteins - blood</subject><subject>Metalloproteins - isolation &amp; purification</subject><subject>Other metalloproteins</subject><subject>Proteins</subject><subject>Silicon Dioxide</subject><subject>Sodium - blood</subject><subject>Sodium - isolation &amp; purification</subject><subject>Spectrophotometry, Ultraviolet</subject><subject>Zinc - blood</subject><subject>Zinc - isolation &amp; purification</subject><issn>0378-4347</issn><issn>1387-2273</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNo9Uc1O3DAQ9oEKKPAISD5UqBxSbOfP5lIhVCgSEge4WxNnljVK4tR2VoTX4gXrLKs9jT3z_WjmI-Scs1-c8erqmeW1zIq8qH-q-pKxiucZOyDH-_YR-R7CG2N5wYQ4JIcqIZRQx-TzGUfwEK0bqFvRHiN0nRu9i2gHalw_dviOgaZPQD_1tJlpsB-Y4bvpprDQzNq7HqJ79TCu52v6NEbb27DXjGtM3L3L8kg26AP1qQzbZoNr2Fg3eQpDm_rGbdDPFJO9m-3wSj201kUPJvFOybcVdAHPdvWEvNz9ebn9mz0-3T_c3jxmKBSPGRrOEZQsDNaNLIWUouayFkyaUvKiEYy1HERbisYgL8qKcVEqaMtGgFqx_IRcfMmma_ybMESdtjLYdTCgm4KulWJVpUQCnu-AU9Njq0dve_Cz3h05zX_s5hAMdCsPg7FhDxNCFKVcZH5_wTDttLHodTAWB4OtTQeJunVWc6aXwPU2cL0kq1Wtt4Frlv8HwjGkYg</recordid><startdate>19980410</startdate><enddate>19980410</enddate><creator>Raab, Andrea</creator><creator>Brätter, Peter</creator><general>Elsevier B.V</general><general>Elsevier Science</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19980410</creationdate><title>Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers</title><author>Raab, Andrea ; Brätter, Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e291t-ec11ea984ce7b8528827187208c5814b200d1a2d52bce145601259ad5b2a9f03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Analytical, structural and metabolic biochemistry</topic><topic>Biological and medical sciences</topic><topic>Buffers</topic><topic>Calcium - blood</topic><topic>Calcium - isolation &amp; purification</topic><topic>Chromatography, Gel</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Humans</topic><topic>Hydrogen-Ion Concentration</topic><topic>Indicators and Reagents</topic><topic>Metalloprotein</topic><topic>Metalloproteins</topic><topic>Metalloproteins - blood</topic><topic>Metalloproteins - isolation &amp; purification</topic><topic>Other metalloproteins</topic><topic>Proteins</topic><topic>Silicon Dioxide</topic><topic>Sodium - blood</topic><topic>Sodium - isolation &amp; purification</topic><topic>Spectrophotometry, Ultraviolet</topic><topic>Zinc - blood</topic><topic>Zinc - isolation &amp; purification</topic><toplevel>online_resources</toplevel><creatorcontrib>Raab, Andrea</creatorcontrib><creatorcontrib>Brätter, Peter</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of chromatography. B, Biomedical sciences and applications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Raab, Andrea</au><au>Brätter, Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers</atitle><jtitle>Journal of chromatography. B, Biomedical sciences and applications</jtitle><addtitle>J Chromatogr B Biomed Sci Appl</addtitle><date>1998-04-10</date><risdate>1998</risdate><volume>707</volume><issue>1</issue><spage>17</spage><epage>24</epage><pages>17-24</pages><issn>0378-4347</issn><issn>1387-2273</issn><abstract>A suitable procedure was developed for speciation analysis of metalloprotein complexes in serum using directly coupled size-exclusion chromatography and an element-specific detector. Two column matrices used for size-exclusion chromatography (TSK G 3000 SW and Asahipak GS 520) were investigated with respect to the recovery and retention behaviour for metalloprotein complexes. Optimisation of the separation parameters (buffer type, concentration, pH) was achieved by means of metalloprotein complexes marked with radiotracers. For speciation of serum the matrix in the Asahipak GS column is more efficient. Given optimal eluent characteristics (100 m M Tris, pH 7.4) the recovery of the elements investigated (sodium, calcium, iron and zinc) was 100%. Further, the retention behaviour (retention time, ratios of the peak areas) remained unchanged for several successive separations.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>9613929</pmid><doi>10.1016/S0378-4347(97)00613-0</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-4347
ispartof Journal of chromatography. B, Biomedical sciences and applications, 1998-04, Vol.707 (1), p.17-24
issn 0378-4347
1387-2273
language eng
recordid cdi_proquest_miscellaneous_79906692
source Elsevier
subjects Analytical, structural and metabolic biochemistry
Biological and medical sciences
Buffers
Calcium - blood
Calcium - isolation & purification
Chromatography, Gel
Fundamental and applied biological sciences. Psychology
Humans
Hydrogen-Ion Concentration
Indicators and Reagents
Metalloprotein
Metalloproteins
Metalloproteins - blood
Metalloproteins - isolation & purification
Other metalloproteins
Proteins
Silicon Dioxide
Sodium - blood
Sodium - isolation & purification
Spectrophotometry, Ultraviolet
Zinc - blood
Zinc - isolation & purification
title Separation of metalloprotein complexes in serum by size-exclusion chromatography: Optimisation of the separation parameters retention behaviour and recovery employing radiotracers
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T23%3A59%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Separation%20of%20metalloprotein%20complexes%20in%20serum%20by%20size-exclusion%20chromatography:%20Optimisation%20of%20the%20separation%20parameters%20retention%20behaviour%20and%20recovery%20employing%20radiotracers&rft.jtitle=Journal%20of%20chromatography.%20B,%20Biomedical%20sciences%20and%20applications&rft.au=Raab,%20Andrea&rft.date=1998-04-10&rft.volume=707&rft.issue=1&rft.spage=17&rft.epage=24&rft.pages=17-24&rft.issn=0378-4347&rft_id=info:doi/10.1016/S0378-4347(97)00613-0&rft_dat=%3Cproquest_pubme%3E79906692%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-e291t-ec11ea984ce7b8528827187208c5814b200d1a2d52bce145601259ad5b2a9f03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=79906692&rft_id=info:pmid/9613929&rfr_iscdi=true