Use of the Cygnus GlucoWatch Biographer at a Diabetes Camp

Detection and prevention of nocturnal hypoglycemia is a major medical concern at diabetes camps. We conducted an open-label trial of the Cygnus GlucoWatch biographer to detect nocturnal hypoglycemia in a diabetes camp, a nonclinical environment with multiple activities. Forty-five campers (7-17 year...

Full description

Saved in:
Bibliographic Details
Published in:Pediatrics (Evanston) 2004-01, Vol.113 (1), p.108-111
Main Authors: Gandrud, Laura M, Paguntalan, Helen U, Van Wyhe, M. Michelle, Kunselman, Betsy L, Leptien, Amy D, Wilson, Darrell M, Eastman, Richard C, Buckingham, Bruce A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Detection and prevention of nocturnal hypoglycemia is a major medical concern at diabetes camps. We conducted an open-label trial of the Cygnus GlucoWatch biographer to detect nocturnal hypoglycemia in a diabetes camp, a nonclinical environment with multiple activities. Forty-five campers (7-17 years old) wore a biographer. The biographer was placed on the arm at 6:00 PM, with the low alarm set to 85 mg/dL (4.7 mmol/L). Overnight glucose monitoring occurred per usual camp protocol. Counselors were to check and record blood glucose values if the biographer alarmed. Biographers were worn for 154 nights by 45 campers. After a 3-hour warm-up period, 67% of biographers were calibrated, of which 28% were worn the entire night (12 hours). Thirty-four percent of readings were skipped because of: "data errors" (65%), sweat (20%), and temperature change (16%). Reported biographer values correlated with meter glucose values measured 11 to 20 minutes later (r = 0.90). Of 20 low-glucose alarms with corresponding meter values measured within 20 minutes, there were 10 true-positive alarms, 10 false-positive alarms, and no false-negative alarms. Campers reported sleep disruption 32% of the nights, and 74% found the biographer helpful. Campers reported they would wear the biographer 4 to 5 nights each week. Half of the biographer low-glucose alarms that had corresponding blood meter values were true-positive alarms, and the remaining were false-positive alarms. There was close correlation between the biographer and meter glucose values. The majority of campers found the biographer helpful and would use it at home.
ISSN:0031-4005
1098-4275
DOI:10.1542/peds.113.1.108