Loading…
Arterial stenting with self-expandable and balloon-expandable endoprostheses
Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now av...
Saved in:
Published in: | International journal of cardiac imaging 1990-06, Vol.5 (2-3), p.163-171 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Coronary angioplasty is complicated by acute occlusion (within 24 hours) and late restenosis (within 6 months) in 2-5% and 20-40% of the cases, respectively. Vascular endoprostheses (stents) may provide the cardiologist with a solution to some of these complications. Several stent-devices are now available for experimental and clinical evaluation. In this study we describe our experience with two metallic stents in normal arteries of swine. Self-expandable, stainless steel stents (3.5 mm diameter) were implanted in 17 peripheral arteries, eight of which were deendothelialized by prior balloon angioplasty. Following implantation, the animals received antithrombotic therapy with acenocoumarol and aspirin (8 stents), or aspirin alone (9 stents). After 1 week repeat angiography was performed, which showed patency of all stented arteries. Microscopy showed complete covering by neointima, 80 microns in thickness. This self-expandable stent (SES) and a balloon-expandable stent (BES), constructed of tantalum, were implanted in normal coronary arteries. SES (3.0 and 3.5 mm) receiving animals were treated with coumadines (10 stents) or received no antithrombotic treatment (16 stents) after implantation. BES receiving animals were also not treated (10 stents). Three untreated animals with SES died suddenly within 48 hours. Postmortem examination showed partial or complete thrombosis of all six stents in these animals, resulting in a patency rate of 62% after 1 week. All animals with SES, which were treated with coumadines, and all animals with BES (untreated) had patent stents after one week. It is concluded that SES implanted in normal coronary arteries of pigs, which do not receive additional antithrombotic treatment, show a 38% occlusion rate within 48 hours, but show 100% patency after 1 week, when the animals are treated with coumadines. BES implanted in normal coronary arteries of pigs, which do not receive antithrombotic drugs, are 100% patent after 1 week. |
---|---|
ISSN: | 0167-9899 1573-0743 |
DOI: | 10.1007/BF01833985 |