Loading…
Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma
We describe a simplified and rapid liquid chromatographic determination of antipyrine clearance (CLAP) calculated from peak height ratios of drug/internal standard. Saliva or plasma was collected 24 hr after the oral administration of 1 g of antipyrine to the subject. A 25-microliter aliquot of the...
Saved in:
Published in: | Pharmaceutical research 1991-02, Vol.8 (2), p.269-272 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c282t-6943ab1d919c10c24d2b732d8457164cbfd86a8532d955db471fb5c5fc60d35c3 |
---|---|
cites | |
container_end_page | 272 |
container_issue | 2 |
container_start_page | 269 |
container_title | Pharmaceutical research |
container_volume | 8 |
creator | ADNAN EL-YAZIGI RAINES, D. A HATIM ALI SIECK, J ERNST, P DOSSING, M |
description | We describe a simplified and rapid liquid chromatographic determination of antipyrine clearance (CLAP) calculated from peak height ratios of drug/internal standard. Saliva or plasma was collected 24 hr after the oral administration of 1 g of antipyrine to the subject. A 25-microliter aliquot of the sample is deproteinized with acetonitrile containing 3-nitrophenol (internal standard) and injected into a radial compression module equipped with a 10-micron, 8 mm x 10-cm C18 cartridge, using a 0.025 M aqueous solution of sodium acetate and acetonitrile (88.5:11.5). The minimum measurable concentration was 0.2 microgram/ml. The obtained CLAP values in five healthy subjects and five patients with chronic liver disease coincided well (r greater than 0.9994) with those generated by the use of an established method. The antipyrine clearance in the healthy subjects ranged from 2.203 to 5.721 liters/hr, while in patients with chronic liver disease it was significantly (P less than 0.0027) less (range, 0.544 to 1.103 liter/hr). We also determined antipyrine clearance in two of these subjects given lower doses of this drug and found that the dose has no significant impact on this parameter. |
doi_str_mv | 10.1023/A:1015816825920 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_80539445</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80539445</sourcerecordid><originalsourceid>FETCH-LOGICAL-c282t-6943ab1d919c10c24d2b732d8457164cbfd86a8532d955db471fb5c5fc60d35c3</originalsourceid><addsrcrecordid>eNo9kE1LxDAYhIMo67p69iTkordqkiZt4m1Z_IIFDyp4K2-T1I2kH5u0Qv-9VYungZln5jAInVNyTQlLb9a3lFAhaSaZUIwcoCUVeZoowt8P0ZLkjCcy5_QYncT4SQiRVPEFWrCpKyVZoubF1Z13lbMGG9vbULsGetc2uK0wNL3rxuAai7W3EKDRFpcj9m4_OIP1LrQ19O1HgG43_hZw7XRoI0yb9seI4N0X4DbgzkOs4RQdVeCjPZt1hd7u7143j8n2-eFps94mmknWJ5niKZTUKKo0JZpxw8o8ZUZykdOM67IyMgMpJksJYUqe06oUWlQ6IyYVOl2hq7_dLrT7wca-qF3U1ntobDvEQhKRKs7FBF7M4FDW1hRdcDWEsZgPmvLLOYeowVc_H7j4j1GVSylYnn4DB952Ng</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80539445</pqid></control><display><type>article</type><title>Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma</title><source>Springer Online Journal Archives (Through 1996)</source><creator>ADNAN EL-YAZIGI ; RAINES, D. A ; HATIM ALI ; SIECK, J ; ERNST, P ; DOSSING, M</creator><creatorcontrib>ADNAN EL-YAZIGI ; RAINES, D. A ; HATIM ALI ; SIECK, J ; ERNST, P ; DOSSING, M</creatorcontrib><description>We describe a simplified and rapid liquid chromatographic determination of antipyrine clearance (CLAP) calculated from peak height ratios of drug/internal standard. Saliva or plasma was collected 24 hr after the oral administration of 1 g of antipyrine to the subject. A 25-microliter aliquot of the sample is deproteinized with acetonitrile containing 3-nitrophenol (internal standard) and injected into a radial compression module equipped with a 10-micron, 8 mm x 10-cm C18 cartridge, using a 0.025 M aqueous solution of sodium acetate and acetonitrile (88.5:11.5). The minimum measurable concentration was 0.2 microgram/ml. The obtained CLAP values in five healthy subjects and five patients with chronic liver disease coincided well (r greater than 0.9994) with those generated by the use of an established method. The antipyrine clearance in the healthy subjects ranged from 2.203 to 5.721 liters/hr, while in patients with chronic liver disease it was significantly (P less than 0.0027) less (range, 0.544 to 1.103 liter/hr). We also determined antipyrine clearance in two of these subjects given lower doses of this drug and found that the dose has no significant impact on this parameter.</description><identifier>ISSN: 0724-8741</identifier><identifier>EISSN: 1573-904X</identifier><identifier>DOI: 10.1023/A:1015816825920</identifier><identifier>PMID: 2023880</identifier><identifier>CODEN: PHREEB</identifier><language>eng</language><publisher>New York, NY: Springer</publisher><subject>Analysis ; Antipyrine - blood ; Antipyrine - pharmacokinetics ; Biological and medical sciences ; Chromatography, Liquid ; General pharmacology ; Humans ; Medical sciences ; Metabolic Clearance Rate ; Pharmacology. Drug treatments ; Saliva - metabolism</subject><ispartof>Pharmaceutical research, 1991-02, Vol.8 (2), p.269-272</ispartof><rights>1991 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c282t-6943ab1d919c10c24d2b732d8457164cbfd86a8532d955db471fb5c5fc60d35c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=19788527$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2023880$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ADNAN EL-YAZIGI</creatorcontrib><creatorcontrib>RAINES, D. A</creatorcontrib><creatorcontrib>HATIM ALI</creatorcontrib><creatorcontrib>SIECK, J</creatorcontrib><creatorcontrib>ERNST, P</creatorcontrib><creatorcontrib>DOSSING, M</creatorcontrib><title>Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma</title><title>Pharmaceutical research</title><addtitle>Pharm Res</addtitle><description>We describe a simplified and rapid liquid chromatographic determination of antipyrine clearance (CLAP) calculated from peak height ratios of drug/internal standard. Saliva or plasma was collected 24 hr after the oral administration of 1 g of antipyrine to the subject. A 25-microliter aliquot of the sample is deproteinized with acetonitrile containing 3-nitrophenol (internal standard) and injected into a radial compression module equipped with a 10-micron, 8 mm x 10-cm C18 cartridge, using a 0.025 M aqueous solution of sodium acetate and acetonitrile (88.5:11.5). The minimum measurable concentration was 0.2 microgram/ml. The obtained CLAP values in five healthy subjects and five patients with chronic liver disease coincided well (r greater than 0.9994) with those generated by the use of an established method. The antipyrine clearance in the healthy subjects ranged from 2.203 to 5.721 liters/hr, while in patients with chronic liver disease it was significantly (P less than 0.0027) less (range, 0.544 to 1.103 liter/hr). We also determined antipyrine clearance in two of these subjects given lower doses of this drug and found that the dose has no significant impact on this parameter.</description><subject>Analysis</subject><subject>Antipyrine - blood</subject><subject>Antipyrine - pharmacokinetics</subject><subject>Biological and medical sciences</subject><subject>Chromatography, Liquid</subject><subject>General pharmacology</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Metabolic Clearance Rate</subject><subject>Pharmacology. Drug treatments</subject><subject>Saliva - metabolism</subject><issn>0724-8741</issn><issn>1573-904X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><recordid>eNo9kE1LxDAYhIMo67p69iTkordqkiZt4m1Z_IIFDyp4K2-T1I2kH5u0Qv-9VYungZln5jAInVNyTQlLb9a3lFAhaSaZUIwcoCUVeZoowt8P0ZLkjCcy5_QYncT4SQiRVPEFWrCpKyVZoubF1Z13lbMGG9vbULsGetc2uK0wNL3rxuAai7W3EKDRFpcj9m4_OIP1LrQ19O1HgG43_hZw7XRoI0yb9seI4N0X4DbgzkOs4RQdVeCjPZt1hd7u7143j8n2-eFps94mmknWJ5niKZTUKKo0JZpxw8o8ZUZykdOM67IyMgMpJksJYUqe06oUWlQ6IyYVOl2hq7_dLrT7wca-qF3U1ntobDvEQhKRKs7FBF7M4FDW1hRdcDWEsZgPmvLLOYeowVc_H7j4j1GVSylYnn4DB952Ng</recordid><startdate>19910201</startdate><enddate>19910201</enddate><creator>ADNAN EL-YAZIGI</creator><creator>RAINES, D. A</creator><creator>HATIM ALI</creator><creator>SIECK, J</creator><creator>ERNST, P</creator><creator>DOSSING, M</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19910201</creationdate><title>Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma</title><author>ADNAN EL-YAZIGI ; RAINES, D. A ; HATIM ALI ; SIECK, J ; ERNST, P ; DOSSING, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c282t-6943ab1d919c10c24d2b732d8457164cbfd86a8532d955db471fb5c5fc60d35c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Analysis</topic><topic>Antipyrine - blood</topic><topic>Antipyrine - pharmacokinetics</topic><topic>Biological and medical sciences</topic><topic>Chromatography, Liquid</topic><topic>General pharmacology</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Metabolic Clearance Rate</topic><topic>Pharmacology. Drug treatments</topic><topic>Saliva - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ADNAN EL-YAZIGI</creatorcontrib><creatorcontrib>RAINES, D. A</creatorcontrib><creatorcontrib>HATIM ALI</creatorcontrib><creatorcontrib>SIECK, J</creatorcontrib><creatorcontrib>ERNST, P</creatorcontrib><creatorcontrib>DOSSING, M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Pharmaceutical research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ADNAN EL-YAZIGI</au><au>RAINES, D. A</au><au>HATIM ALI</au><au>SIECK, J</au><au>ERNST, P</au><au>DOSSING, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma</atitle><jtitle>Pharmaceutical research</jtitle><addtitle>Pharm Res</addtitle><date>1991-02-01</date><risdate>1991</risdate><volume>8</volume><issue>2</issue><spage>269</spage><epage>272</epage><pages>269-272</pages><issn>0724-8741</issn><eissn>1573-904X</eissn><coden>PHREEB</coden><abstract>We describe a simplified and rapid liquid chromatographic determination of antipyrine clearance (CLAP) calculated from peak height ratios of drug/internal standard. Saliva or plasma was collected 24 hr after the oral administration of 1 g of antipyrine to the subject. A 25-microliter aliquot of the sample is deproteinized with acetonitrile containing 3-nitrophenol (internal standard) and injected into a radial compression module equipped with a 10-micron, 8 mm x 10-cm C18 cartridge, using a 0.025 M aqueous solution of sodium acetate and acetonitrile (88.5:11.5). The minimum measurable concentration was 0.2 microgram/ml. The obtained CLAP values in five healthy subjects and five patients with chronic liver disease coincided well (r greater than 0.9994) with those generated by the use of an established method. The antipyrine clearance in the healthy subjects ranged from 2.203 to 5.721 liters/hr, while in patients with chronic liver disease it was significantly (P less than 0.0027) less (range, 0.544 to 1.103 liter/hr). We also determined antipyrine clearance in two of these subjects given lower doses of this drug and found that the dose has no significant impact on this parameter.</abstract><cop>New York, NY</cop><pub>Springer</pub><pmid>2023880</pmid><doi>10.1023/A:1015816825920</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0724-8741 |
ispartof | Pharmaceutical research, 1991-02, Vol.8 (2), p.269-272 |
issn | 0724-8741 1573-904X |
language | eng |
recordid | cdi_proquest_miscellaneous_80539445 |
source | Springer Online Journal Archives (Through 1996) |
subjects | Analysis Antipyrine - blood Antipyrine - pharmacokinetics Biological and medical sciences Chromatography, Liquid General pharmacology Humans Medical sciences Metabolic Clearance Rate Pharmacology. Drug treatments Saliva - metabolism |
title | Simplified determination of antipyrine clearance by liquid chromatography of a microsample of saliva or plasma |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T16%3A59%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simplified%20determination%20of%20antipyrine%20clearance%20by%20liquid%20chromatography%20of%20a%20microsample%20of%20saliva%20or%20plasma&rft.jtitle=Pharmaceutical%20research&rft.au=ADNAN%20EL-YAZIGI&rft.date=1991-02-01&rft.volume=8&rft.issue=2&rft.spage=269&rft.epage=272&rft.pages=269-272&rft.issn=0724-8741&rft.eissn=1573-904X&rft.coden=PHREEB&rft_id=info:doi/10.1023/A:1015816825920&rft_dat=%3Cproquest_pubme%3E80539445%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c282t-6943ab1d919c10c24d2b732d8457164cbfd86a8532d955db471fb5c5fc60d35c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=80539445&rft_id=info:pmid/2023880&rfr_iscdi=true |