Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia

The dynamic nature of blood flow during hyperthermia therapy has made the control of minimum tumour temperature a difficult task. The paper presents initial studies of a novel approach to closed-loop control of local minimum tissue temperatures utilising a newly developed estimation algorithm for us...

Full description

Saved in:
Bibliographic Details
Published in:Medical & biological engineering & computing 1991-03, Vol.29 (2), p.197-206
Main Authors: DEFORD, J. A, BABBS, C. F, PATEL, U. H, FEARNOT, N. E, MARCHOSKY, J. A, MORAN, C. J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3
cites cdi_FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3
container_end_page 206
container_issue 2
container_start_page 197
container_title Medical & biological engineering & computing
container_volume 29
creator DEFORD, J. A
BABBS, C. F
PATEL, U. H
FEARNOT, N. E
MARCHOSKY, J. A
MORAN, C. J
description The dynamic nature of blood flow during hyperthermia therapy has made the control of minimum tumour temperature a difficult task. The paper presents initial studies of a novel approach to closed-loop control of local minimum tissue temperatures utilising a newly developed estimation algorithm for use with conductive interstitial heating systems. The local minimum tumour temperature is explicitly estimated from the power required to maintain each member of an array of electrically heated catheters at a known temperature, in conjunction with a new bioheat equation-based algorithm to predict the 'droop' or fractional decline in tissue temperature between heated catheters. A closed loop controller utilises the estimated minimum temperature near each catheter as a feedback parameter, which reflects variations in local blood flow. In response the controller alters delivered power to each catheter to compensate for changes in blood flow. The validity and stability of this estimation/control scheme were tested in computer simulations and in closed-loop control of nine patient treatments. The average estimation error from patient data analysis of 21 sites at which temperature was independently measured (three per patient) was 0.0 degree C, with a standard deviation of 0.8 degree C. These results suggest that estimation of local minimum temperature and feedback control of power delivery can be employed effectively during conductive interstitial heat therapy of intracranial tumours in man.
doi_str_mv 10.1007/BF02447108
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_80704789</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80704789</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3</originalsourceid><addsrcrecordid>eNpFkUFv1DAQhS1EVZbChTuSD4gDUspM4sTOkRYKSJV6gXPkOGPWENuL7RT1b_CLSbQrepqR3qfv8B5jrxAuEUC-v7qBWgiJoJ6wHUqBFQghnrIdoIAKENUz9jznnwA1trU4Z-eoWol1t2N_P1J2PwLXYeJ0r-dFFxcDj5abOWaaqjnGA7dE06jNL25iKCnOW-5dcH7xvJA_UNJlSZS5C3y_eB3WpyRtkg5Oz7wsPi4p85JIF5r4H1f2G0EpF1c2Yv-wOsqeknf6BTuzes708nQv2PebT9-uv1S3d5-_Xn-4rUyDWKpuIml7qFurjOyggVrZFlGg7FUjdNvTqLtGCrM10xvREOIIJGFUKzTa5oK9PXoPKf5eKJfBu2xonnWguORBgQQhVb-C746gSTHnRHY4JOd1ehgQhm2A4XGAFX59si6jp-kRPTa-5m9Ouc5Gz3atyLj8H2vF6ui65h-7EI9z</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80704789</pqid></control><display><type>article</type><title>Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia</title><source>SpringerLink Online Journals Archive Complete</source><creator>DEFORD, J. A ; BABBS, C. F ; PATEL, U. H ; FEARNOT, N. E ; MARCHOSKY, J. A ; MORAN, C. J</creator><creatorcontrib>DEFORD, J. A ; BABBS, C. F ; PATEL, U. H ; FEARNOT, N. E ; MARCHOSKY, J. A ; MORAN, C. J</creatorcontrib><description>The dynamic nature of blood flow during hyperthermia therapy has made the control of minimum tumour temperature a difficult task. The paper presents initial studies of a novel approach to closed-loop control of local minimum tissue temperatures utilising a newly developed estimation algorithm for use with conductive interstitial heating systems. The local minimum tumour temperature is explicitly estimated from the power required to maintain each member of an array of electrically heated catheters at a known temperature, in conjunction with a new bioheat equation-based algorithm to predict the 'droop' or fractional decline in tissue temperature between heated catheters. A closed loop controller utilises the estimated minimum temperature near each catheter as a feedback parameter, which reflects variations in local blood flow. In response the controller alters delivered power to each catheter to compensate for changes in blood flow. The validity and stability of this estimation/control scheme were tested in computer simulations and in closed-loop control of nine patient treatments. The average estimation error from patient data analysis of 21 sites at which temperature was independently measured (three per patient) was 0.0 degree C, with a standard deviation of 0.8 degree C. These results suggest that estimation of local minimum temperature and feedback control of power delivery can be employed effectively during conductive interstitial heat therapy of intracranial tumours in man.</description><identifier>ISSN: 0140-0118</identifier><identifier>EISSN: 1741-0444</identifier><identifier>DOI: 10.1007/BF02447108</identifier><identifier>PMID: 1857126</identifier><language>eng</language><publisher>Heidelberg: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Brain Neoplasms - therapy ; Computer Simulation ; Feedback ; Female ; Humans ; Hyperthermia, Induced - methods ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Models, Biological ; Temperature</subject><ispartof>Medical &amp; biological engineering &amp; computing, 1991-03, Vol.29 (2), p.197-206</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3</citedby><cites>FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=5408366$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1857126$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>DEFORD, J. A</creatorcontrib><creatorcontrib>BABBS, C. F</creatorcontrib><creatorcontrib>PATEL, U. H</creatorcontrib><creatorcontrib>FEARNOT, N. E</creatorcontrib><creatorcontrib>MARCHOSKY, J. A</creatorcontrib><creatorcontrib>MORAN, C. J</creatorcontrib><title>Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia</title><title>Medical &amp; biological engineering &amp; computing</title><addtitle>Med Biol Eng Comput</addtitle><description>The dynamic nature of blood flow during hyperthermia therapy has made the control of minimum tumour temperature a difficult task. The paper presents initial studies of a novel approach to closed-loop control of local minimum tissue temperatures utilising a newly developed estimation algorithm for use with conductive interstitial heating systems. The local minimum tumour temperature is explicitly estimated from the power required to maintain each member of an array of electrically heated catheters at a known temperature, in conjunction with a new bioheat equation-based algorithm to predict the 'droop' or fractional decline in tissue temperature between heated catheters. A closed loop controller utilises the estimated minimum temperature near each catheter as a feedback parameter, which reflects variations in local blood flow. In response the controller alters delivered power to each catheter to compensate for changes in blood flow. The validity and stability of this estimation/control scheme were tested in computer simulations and in closed-loop control of nine patient treatments. The average estimation error from patient data analysis of 21 sites at which temperature was independently measured (three per patient) was 0.0 degree C, with a standard deviation of 0.8 degree C. These results suggest that estimation of local minimum temperature and feedback control of power delivery can be employed effectively during conductive interstitial heat therapy of intracranial tumours in man.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Brain Neoplasms - therapy</subject><subject>Computer Simulation</subject><subject>Feedback</subject><subject>Female</subject><subject>Humans</subject><subject>Hyperthermia, Induced - methods</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Models, Biological</subject><subject>Temperature</subject><issn>0140-0118</issn><issn>1741-0444</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1991</creationdate><recordtype>article</recordtype><recordid>eNpFkUFv1DAQhS1EVZbChTuSD4gDUspM4sTOkRYKSJV6gXPkOGPWENuL7RT1b_CLSbQrepqR3qfv8B5jrxAuEUC-v7qBWgiJoJ6wHUqBFQghnrIdoIAKENUz9jznnwA1trU4Z-eoWol1t2N_P1J2PwLXYeJ0r-dFFxcDj5abOWaaqjnGA7dE06jNL25iKCnOW-5dcH7xvJA_UNJlSZS5C3y_eB3WpyRtkg5Oz7wsPi4p85JIF5r4H1f2G0EpF1c2Yv-wOsqeknf6BTuzes708nQv2PebT9-uv1S3d5-_Xn-4rUyDWKpuIml7qFurjOyggVrZFlGg7FUjdNvTqLtGCrM10xvREOIIJGFUKzTa5oK9PXoPKf5eKJfBu2xonnWguORBgQQhVb-C746gSTHnRHY4JOd1ehgQhm2A4XGAFX59si6jp-kRPTa-5m9Ouc5Gz3atyLj8H2vF6ui65h-7EI9z</recordid><startdate>19910301</startdate><enddate>19910301</enddate><creator>DEFORD, J. A</creator><creator>BABBS, C. F</creator><creator>PATEL, U. H</creator><creator>FEARNOT, N. E</creator><creator>MARCHOSKY, J. A</creator><creator>MORAN, C. J</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19910301</creationdate><title>Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia</title><author>DEFORD, J. A ; BABBS, C. F ; PATEL, U. H ; FEARNOT, N. E ; MARCHOSKY, J. A ; MORAN, C. J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1991</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Brain Neoplasms - therapy</topic><topic>Computer Simulation</topic><topic>Feedback</topic><topic>Female</topic><topic>Humans</topic><topic>Hyperthermia, Induced - methods</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Models, Biological</topic><topic>Temperature</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>DEFORD, J. A</creatorcontrib><creatorcontrib>BABBS, C. F</creatorcontrib><creatorcontrib>PATEL, U. H</creatorcontrib><creatorcontrib>FEARNOT, N. E</creatorcontrib><creatorcontrib>MARCHOSKY, J. A</creatorcontrib><creatorcontrib>MORAN, C. J</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical &amp; biological engineering &amp; computing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>DEFORD, J. A</au><au>BABBS, C. F</au><au>PATEL, U. H</au><au>FEARNOT, N. E</au><au>MARCHOSKY, J. A</au><au>MORAN, C. J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia</atitle><jtitle>Medical &amp; biological engineering &amp; computing</jtitle><addtitle>Med Biol Eng Comput</addtitle><date>1991-03-01</date><risdate>1991</risdate><volume>29</volume><issue>2</issue><spage>197</spage><epage>206</epage><pages>197-206</pages><issn>0140-0118</issn><eissn>1741-0444</eissn><abstract>The dynamic nature of blood flow during hyperthermia therapy has made the control of minimum tumour temperature a difficult task. The paper presents initial studies of a novel approach to closed-loop control of local minimum tissue temperatures utilising a newly developed estimation algorithm for use with conductive interstitial heating systems. The local minimum tumour temperature is explicitly estimated from the power required to maintain each member of an array of electrically heated catheters at a known temperature, in conjunction with a new bioheat equation-based algorithm to predict the 'droop' or fractional decline in tissue temperature between heated catheters. A closed loop controller utilises the estimated minimum temperature near each catheter as a feedback parameter, which reflects variations in local blood flow. In response the controller alters delivered power to each catheter to compensate for changes in blood flow. The validity and stability of this estimation/control scheme were tested in computer simulations and in closed-loop control of nine patient treatments. The average estimation error from patient data analysis of 21 sites at which temperature was independently measured (three per patient) was 0.0 degree C, with a standard deviation of 0.8 degree C. These results suggest that estimation of local minimum temperature and feedback control of power delivery can be employed effectively during conductive interstitial heat therapy of intracranial tumours in man.</abstract><cop>Heidelberg</cop><pub>Springer</pub><pmid>1857126</pmid><doi>10.1007/BF02447108</doi><tpages>10</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0140-0118
ispartof Medical & biological engineering & computing, 1991-03, Vol.29 (2), p.197-206
issn 0140-0118
1741-0444
language eng
recordid cdi_proquest_miscellaneous_80704789
source SpringerLink Online Journals Archive Complete
subjects Adult
Aged
Biological and medical sciences
Brain Neoplasms - therapy
Computer Simulation
Feedback
Female
Humans
Hyperthermia, Induced - methods
Investigative techniques, diagnostic techniques (general aspects)
Male
Medical sciences
Middle Aged
Models, Biological
Temperature
title Design and evaluation of closed-loop feedback control of minimum temperatures in human intracranial tumours treated with interstitial hyperthermia
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T05%3A05%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20evaluation%20of%20closed-loop%20feedback%20control%20of%20minimum%20temperatures%20in%20human%20intracranial%20tumours%20treated%20with%20interstitial%20hyperthermia&rft.jtitle=Medical%20&%20biological%20engineering%20&%20computing&rft.au=DEFORD,%20J.%20A&rft.date=1991-03-01&rft.volume=29&rft.issue=2&rft.spage=197&rft.epage=206&rft.pages=197-206&rft.issn=0140-0118&rft.eissn=1741-0444&rft_id=info:doi/10.1007/BF02447108&rft_dat=%3Cproquest_cross%3E80704789%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c311t-6de7f9025f8c7603028f5114179834a59eba6374c44719c43e11b0e70b8141bf3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=80704789&rft_id=info:pmid/1857126&rfr_iscdi=true