Loading…

Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs

Retrograde transmission of left atrial pressure across the pulmonary capillary bed was studied in dogs employing graduated left atrial pressures. Left atrial pressures below a level of 30 to 35 mm. Hg were transmitted across the pulmonary capillary bed as mean pressures; in the case of higher left a...

Full description

Saved in:
Bibliographic Details
Published in:Circulation research 1954-09, Vol.2 (5), p.426-431
Main Authors: Mueller, Helmut, Gensini, Goffredo, Prevedel, Arthur E, Blount, S Gilbert
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4139-d92f31578db01233e5186d0527c4980be0118326c17ff23cefadc6555337d54b3
cites
container_end_page 431
container_issue 5
container_start_page 426
container_title Circulation research
container_volume 2
creator Mueller, Helmut
Gensini, Goffredo
Prevedel, Arthur E
Blount, S Gilbert
description Retrograde transmission of left atrial pressure across the pulmonary capillary bed was studied in dogs employing graduated left atrial pressures. Left atrial pressures below a level of 30 to 35 mm. Hg were transmitted across the pulmonary capillary bed as mean pressures; in the case of higher left atrial pressures the cyclic changes were transmitted with a certain amount of damping. Pressures were recorded both from the tip of a catheter wedged into a peripheral pulmonary artery and from the occluded main artery of one lung. Pressures recorded from the occluded main artery of one lung are a reflection of cyclic left atrial pressure variations and are less damped than those recorded from a wedged catheter tip.
doi_str_mv 10.1161/01.RES.2.5.426
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81358521</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81358521</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4139-d92f31578db01233e5186d0527c4980be0118326c17ff23cefadc6555337d54b3</originalsourceid><addsrcrecordid>eNpFkctv2zAMxoWhw5p2u-446LSbXVIP2zpm6RMI0CBrz4Ji0403x8okG8X--ypNgJ74wI8Ev4-MfUfIEQu8AszXN79zketcieITm6EWKlO6xDM2AwCTlVLCObuI8Q8AKinMF3aOEg0UQs-YW9MY_EtwDfGn4Ia462Ls_MB9y5fUjnw-hs71fBUoxikQX019pMjndfAx8nH73tn5wYX_fOH2Xd8fsl_U8G7g1_4lfmWfW5dmvp3iJXu-vXla3GfLx7uHxXyZ1QqlyRojWom6rJoNoJCSNFZFA1qUtTIVbAgQKymKGsu2FbKm1jV1obWWsmy02shL9vO4dx_8v4niaJOUmtI9A_kp2gqlrrTABOZH8F1CoNbuQ7dLV1sEezDVAtpkqhVW22RqGvhx2jxtdtR84CcXE6COwKvvRwrxbz-9UrBbcv24tekLIJOmDI1WYFKVHVpGvgEgtoEi</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81358521</pqid></control><display><type>article</type><title>Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs</title><source>Freely Accessible Science Journals</source><creator>Mueller, Helmut ; Gensini, Goffredo ; Prevedel, Arthur E ; Blount, S Gilbert</creator><creatorcontrib>Mueller, Helmut ; Gensini, Goffredo ; Prevedel, Arthur E ; Blount, S Gilbert</creatorcontrib><description>Retrograde transmission of left atrial pressure across the pulmonary capillary bed was studied in dogs employing graduated left atrial pressures. Left atrial pressures below a level of 30 to 35 mm. Hg were transmitted across the pulmonary capillary bed as mean pressures; in the case of higher left atrial pressures the cyclic changes were transmitted with a certain amount of damping. Pressures were recorded both from the tip of a catheter wedged into a peripheral pulmonary artery and from the occluded main artery of one lung. Pressures recorded from the occluded main artery of one lung are a reflection of cyclic left atrial pressure variations and are less damped than those recorded from a wedged catheter tip.</description><identifier>ISSN: 0009-7330</identifier><identifier>EISSN: 1524-4571</identifier><identifier>DOI: 10.1161/01.RES.2.5.426</identifier><identifier>PMID: 13190625</identifier><language>eng</language><publisher>United States: American Heart Association, Inc</publisher><subject>Animals ; Aorta - physiology ; Atrial Pressure ; Capillaries ; Dogs ; Heart ; Humans ; Lung ; Old Medline ; Pulmonary Artery - physiology ; Pulse</subject><ispartof>Circulation research, 1954-09, Vol.2 (5), p.426-431</ispartof><rights>1954 American Heart Association, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4139-d92f31578db01233e5186d0527c4980be0118326c17ff23cefadc6555337d54b3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/13190625$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mueller, Helmut</creatorcontrib><creatorcontrib>Gensini, Goffredo</creatorcontrib><creatorcontrib>Prevedel, Arthur E</creatorcontrib><creatorcontrib>Blount, S Gilbert</creatorcontrib><title>Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs</title><title>Circulation research</title><addtitle>Circ Res</addtitle><description>Retrograde transmission of left atrial pressure across the pulmonary capillary bed was studied in dogs employing graduated left atrial pressures. Left atrial pressures below a level of 30 to 35 mm. Hg were transmitted across the pulmonary capillary bed as mean pressures; in the case of higher left atrial pressures the cyclic changes were transmitted with a certain amount of damping. Pressures were recorded both from the tip of a catheter wedged into a peripheral pulmonary artery and from the occluded main artery of one lung. Pressures recorded from the occluded main artery of one lung are a reflection of cyclic left atrial pressure variations and are less damped than those recorded from a wedged catheter tip.</description><subject>Animals</subject><subject>Aorta - physiology</subject><subject>Atrial Pressure</subject><subject>Capillaries</subject><subject>Dogs</subject><subject>Heart</subject><subject>Humans</subject><subject>Lung</subject><subject>Old Medline</subject><subject>Pulmonary Artery - physiology</subject><subject>Pulse</subject><issn>0009-7330</issn><issn>1524-4571</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1954</creationdate><recordtype>article</recordtype><recordid>eNpFkctv2zAMxoWhw5p2u-446LSbXVIP2zpm6RMI0CBrz4Ji0403x8okG8X--ypNgJ74wI8Ev4-MfUfIEQu8AszXN79zketcieITm6EWKlO6xDM2AwCTlVLCObuI8Q8AKinMF3aOEg0UQs-YW9MY_EtwDfGn4Ia462Ls_MB9y5fUjnw-hs71fBUoxikQX019pMjndfAx8nH73tn5wYX_fOH2Xd8fsl_U8G7g1_4lfmWfW5dmvp3iJXu-vXla3GfLx7uHxXyZ1QqlyRojWom6rJoNoJCSNFZFA1qUtTIVbAgQKymKGsu2FbKm1jV1obWWsmy02shL9vO4dx_8v4niaJOUmtI9A_kp2gqlrrTABOZH8F1CoNbuQ7dLV1sEezDVAtpkqhVW22RqGvhx2jxtdtR84CcXE6COwKvvRwrxbz-9UrBbcv24tekLIJOmDI1WYFKVHVpGvgEgtoEi</recordid><startdate>195409</startdate><enddate>195409</enddate><creator>Mueller, Helmut</creator><creator>Gensini, Goffredo</creator><creator>Prevedel, Arthur E</creator><creator>Blount, S Gilbert</creator><general>American Heart Association, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>195409</creationdate><title>Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs</title><author>Mueller, Helmut ; Gensini, Goffredo ; Prevedel, Arthur E ; Blount, S Gilbert</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4139-d92f31578db01233e5186d0527c4980be0118326c17ff23cefadc6555337d54b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1954</creationdate><topic>Animals</topic><topic>Aorta - physiology</topic><topic>Atrial Pressure</topic><topic>Capillaries</topic><topic>Dogs</topic><topic>Heart</topic><topic>Humans</topic><topic>Lung</topic><topic>Old Medline</topic><topic>Pulmonary Artery - physiology</topic><topic>Pulse</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mueller, Helmut</creatorcontrib><creatorcontrib>Gensini, Goffredo</creatorcontrib><creatorcontrib>Prevedel, Arthur E</creatorcontrib><creatorcontrib>Blount, S Gilbert</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Circulation research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mueller, Helmut</au><au>Gensini, Goffredo</au><au>Prevedel, Arthur E</au><au>Blount, S Gilbert</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs</atitle><jtitle>Circulation research</jtitle><addtitle>Circ Res</addtitle><date>1954-09</date><risdate>1954</risdate><volume>2</volume><issue>5</issue><spage>426</spage><epage>431</epage><pages>426-431</pages><issn>0009-7330</issn><eissn>1524-4571</eissn><abstract>Retrograde transmission of left atrial pressure across the pulmonary capillary bed was studied in dogs employing graduated left atrial pressures. Left atrial pressures below a level of 30 to 35 mm. Hg were transmitted across the pulmonary capillary bed as mean pressures; in the case of higher left atrial pressures the cyclic changes were transmitted with a certain amount of damping. Pressures were recorded both from the tip of a catheter wedged into a peripheral pulmonary artery and from the occluded main artery of one lung. Pressures recorded from the occluded main artery of one lung are a reflection of cyclic left atrial pressure variations and are less damped than those recorded from a wedged catheter tip.</abstract><cop>United States</cop><pub>American Heart Association, Inc</pub><pmid>13190625</pmid><doi>10.1161/01.RES.2.5.426</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0009-7330
ispartof Circulation research, 1954-09, Vol.2 (5), p.426-431
issn 0009-7330
1524-4571
language eng
recordid cdi_proquest_miscellaneous_81358521
source Freely Accessible Science Journals
subjects Animals
Aorta - physiology
Atrial Pressure
Capillaries
Dogs
Heart
Humans
Lung
Old Medline
Pulmonary Artery - physiology
Pulse
title Retrograde Transmission of Left Atrial Pressure Pulses Across the Pulmonary Capillary Bed in Dogs
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T07%3A57%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Retrograde%20Transmission%20of%20Left%20Atrial%20Pressure%20Pulses%20Across%20the%20Pulmonary%20Capillary%20Bed%20in%20Dogs&rft.jtitle=Circulation%20research&rft.au=Mueller,%20Helmut&rft.date=1954-09&rft.volume=2&rft.issue=5&rft.spage=426&rft.epage=431&rft.pages=426-431&rft.issn=0009-7330&rft.eissn=1524-4571&rft_id=info:doi/10.1161/01.RES.2.5.426&rft_dat=%3Cproquest_cross%3E81358521%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4139-d92f31578db01233e5186d0527c4980be0118326c17ff23cefadc6555337d54b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=81358521&rft_id=info:pmid/13190625&rfr_iscdi=true