Loading…
An insertion device for the soft X-ray photochemistry beamline at SPring-8
A figure‐8 undulator is an insertion device (ID) proposed at SPring‐8 to reduce the heat‐load problems encountered with ordinary linear undulators. This device is useful when the K value is high in order to obtain low‐energy photons as the fundamental of the undulator radiation. It has therefore bee...
Saved in:
Published in: | Journal of synchrotron radiation 1998-05, Vol.5 (3), p.459-461 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c4943-617d4a9016cad516c81529240a1103655e791add1e857b09c39c6960765faf3e3 |
---|---|
cites | |
container_end_page | 461 |
container_issue | 3 |
container_start_page | 459 |
container_title | Journal of synchrotron radiation |
container_volume | 5 |
creator | Tanaka, Takashi Maréchal, Xavier-Marie Hara, Toru Tanabe, Toshiya Kitamura, Hideo |
description | A figure‐8 undulator is an insertion device (ID) proposed at SPring‐8 to reduce the heat‐load problems encountered with ordinary linear undulators. This device is useful when the K value is high in order to obtain low‐energy photons as the fundamental of the undulator radiation. It has therefore been adopted as the ID for the soft X‐ray photochemistry beamline (BL27SU) at SPring‐8 because linearly polarized photons between 100 and 2000 eV are necessary for the experiments on this beamline. The figure‐8 undulator for BL27SU is now under construction and, in the first phase of operation, is expected to cover the energy range down to 500 eV. In the second and third phases, the lowest energy may be reduced to 170 and 100 eV, respectively. |
doi_str_mv | 10.1107/S0909049597013733 |
format | article |
fullrecord | <record><control><sourceid>proquest_24P</sourceid><recordid>TN_cdi_proquest_miscellaneous_817618257</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>817618257</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4943-617d4a9016cad516c81529240a1103655e791add1e857b09c39c6960765faf3e3</originalsourceid><addsrcrecordid>eNqFkFFPwjAUhRujEUR_gC-mbz5NW7q26yMhiBKiEhTRl6ZsdzIdG7ZD3b-3BKImPpib9PbhnC_nHoSOKTmjlMjzMVF-QsWVJJRJxnZQkwpCAi4l3_31b6AD514IoUK22T5qUN4WjIe8iQadAmeFA1tlZYETeM9iwGlpcTUH7Mq0wtPAmhov52VVxnNYZK6yNZ6BWeRZAdhUeHxrs-I5iA7RXmpyB0fb3UL3F7277mUwvOlfdTvDIA5VyAJBZRIa5bPEJuH-jXwa1Q6J8TcxwTlIRU2SUIi4nBEVMxULJYgUPDUpA9ZCpxvu0pZvK3CV9qFiyHNTQLlyOqJS0KjNpVfSjTK2pXMWUr202cLYWlOi1w3qPw16z8mWvpotIPlxbCvzgmgj-MhyqP8n6sH4sTdklK7ZwcbqS4TPb6uxr1pIJrl-uO7rydNETvujkR6xL74riPU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>817618257</pqid></control><display><type>article</type><title>An insertion device for the soft X-ray photochemistry beamline at SPring-8</title><source>Wiley Online Library</source><creator>Tanaka, Takashi ; Maréchal, Xavier-Marie ; Hara, Toru ; Tanabe, Toshiya ; Kitamura, Hideo</creator><creatorcontrib>Tanaka, Takashi ; Maréchal, Xavier-Marie ; Hara, Toru ; Tanabe, Toshiya ; Kitamura, Hideo</creatorcontrib><description>A figure‐8 undulator is an insertion device (ID) proposed at SPring‐8 to reduce the heat‐load problems encountered with ordinary linear undulators. This device is useful when the K value is high in order to obtain low‐energy photons as the fundamental of the undulator radiation. It has therefore been adopted as the ID for the soft X‐ray photochemistry beamline (BL27SU) at SPring‐8 because linearly polarized photons between 100 and 2000 eV are necessary for the experiments on this beamline. The figure‐8 undulator for BL27SU is now under construction and, in the first phase of operation, is expected to cover the energy range down to 500 eV. In the second and third phases, the lowest energy may be reduced to 170 and 100 eV, respectively.</description><identifier>ISSN: 1600-5775</identifier><identifier>ISSN: 0909-0495</identifier><identifier>EISSN: 1600-5775</identifier><identifier>DOI: 10.1107/S0909049597013733</identifier><identifier>PMID: 15263545</identifier><language>eng</language><publisher>5 Abbey Square, Chester, Cheshire CH1 2HU, England: International Union of Crystallography</publisher><subject>low heat loads ; undulators</subject><ispartof>Journal of synchrotron radiation, 1998-05, Vol.5 (3), p.459-461</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4943-617d4a9016cad516c81529240a1103655e791add1e857b09c39c6960765faf3e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1107%2FS0909049597013733$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1107%2FS0909049597013733$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,11562,27924,27925,46052,46476</link.rule.ids><linktorsrc>$$Uhttps://onlinelibrary.wiley.com/doi/abs/10.1107%2FS0909049597013733$$EView_record_in_Wiley-Blackwell$$FView_record_in_$$GWiley-Blackwell</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15263545$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tanaka, Takashi</creatorcontrib><creatorcontrib>Maréchal, Xavier-Marie</creatorcontrib><creatorcontrib>Hara, Toru</creatorcontrib><creatorcontrib>Tanabe, Toshiya</creatorcontrib><creatorcontrib>Kitamura, Hideo</creatorcontrib><title>An insertion device for the soft X-ray photochemistry beamline at SPring-8</title><title>Journal of synchrotron radiation</title><addtitle>J. Synchrotron Rad</addtitle><description>A figure‐8 undulator is an insertion device (ID) proposed at SPring‐8 to reduce the heat‐load problems encountered with ordinary linear undulators. This device is useful when the K value is high in order to obtain low‐energy photons as the fundamental of the undulator radiation. It has therefore been adopted as the ID for the soft X‐ray photochemistry beamline (BL27SU) at SPring‐8 because linearly polarized photons between 100 and 2000 eV are necessary for the experiments on this beamline. The figure‐8 undulator for BL27SU is now under construction and, in the first phase of operation, is expected to cover the energy range down to 500 eV. In the second and third phases, the lowest energy may be reduced to 170 and 100 eV, respectively.</description><subject>low heat loads</subject><subject>undulators</subject><issn>1600-5775</issn><issn>0909-0495</issn><issn>1600-5775</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkFFPwjAUhRujEUR_gC-mbz5NW7q26yMhiBKiEhTRl6ZsdzIdG7ZD3b-3BKImPpib9PbhnC_nHoSOKTmjlMjzMVF-QsWVJJRJxnZQkwpCAi4l3_31b6AD514IoUK22T5qUN4WjIe8iQadAmeFA1tlZYETeM9iwGlpcTUH7Mq0wtPAmhov52VVxnNYZK6yNZ6BWeRZAdhUeHxrs-I5iA7RXmpyB0fb3UL3F7277mUwvOlfdTvDIA5VyAJBZRIa5bPEJuH-jXwa1Q6J8TcxwTlIRU2SUIi4nBEVMxULJYgUPDUpA9ZCpxvu0pZvK3CV9qFiyHNTQLlyOqJS0KjNpVfSjTK2pXMWUr202cLYWlOi1w3qPw16z8mWvpotIPlxbCvzgmgj-MhyqP8n6sH4sTdklK7ZwcbqS4TPb6uxr1pIJrl-uO7rydNETvujkR6xL74riPU</recordid><startdate>19980501</startdate><enddate>19980501</enddate><creator>Tanaka, Takashi</creator><creator>Maréchal, Xavier-Marie</creator><creator>Hara, Toru</creator><creator>Tanabe, Toshiya</creator><creator>Kitamura, Hideo</creator><general>International Union of Crystallography</general><scope>BSCLL</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19980501</creationdate><title>An insertion device for the soft X-ray photochemistry beamline at SPring-8</title><author>Tanaka, Takashi ; Maréchal, Xavier-Marie ; Hara, Toru ; Tanabe, Toshiya ; Kitamura, Hideo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4943-617d4a9016cad516c81529240a1103655e791add1e857b09c39c6960765faf3e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>low heat loads</topic><topic>undulators</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tanaka, Takashi</creatorcontrib><creatorcontrib>Maréchal, Xavier-Marie</creatorcontrib><creatorcontrib>Hara, Toru</creatorcontrib><creatorcontrib>Tanabe, Toshiya</creatorcontrib><creatorcontrib>Kitamura, Hideo</creatorcontrib><collection>Istex</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of synchrotron radiation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Tanaka, Takashi</au><au>Maréchal, Xavier-Marie</au><au>Hara, Toru</au><au>Tanabe, Toshiya</au><au>Kitamura, Hideo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An insertion device for the soft X-ray photochemistry beamline at SPring-8</atitle><jtitle>Journal of synchrotron radiation</jtitle><addtitle>J. Synchrotron Rad</addtitle><date>1998-05-01</date><risdate>1998</risdate><volume>5</volume><issue>3</issue><spage>459</spage><epage>461</epage><pages>459-461</pages><issn>1600-5775</issn><issn>0909-0495</issn><eissn>1600-5775</eissn><abstract>A figure‐8 undulator is an insertion device (ID) proposed at SPring‐8 to reduce the heat‐load problems encountered with ordinary linear undulators. This device is useful when the K value is high in order to obtain low‐energy photons as the fundamental of the undulator radiation. It has therefore been adopted as the ID for the soft X‐ray photochemistry beamline (BL27SU) at SPring‐8 because linearly polarized photons between 100 and 2000 eV are necessary for the experiments on this beamline. The figure‐8 undulator for BL27SU is now under construction and, in the first phase of operation, is expected to cover the energy range down to 500 eV. In the second and third phases, the lowest energy may be reduced to 170 and 100 eV, respectively.</abstract><cop>5 Abbey Square, Chester, Cheshire CH1 2HU, England</cop><pub>International Union of Crystallography</pub><pmid>15263545</pmid><doi>10.1107/S0909049597013733</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 1600-5775 |
ispartof | Journal of synchrotron radiation, 1998-05, Vol.5 (3), p.459-461 |
issn | 1600-5775 0909-0495 1600-5775 |
language | eng |
recordid | cdi_proquest_miscellaneous_817618257 |
source | Wiley Online Library |
subjects | low heat loads undulators |
title | An insertion device for the soft X-ray photochemistry beamline at SPring-8 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T20%3A30%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_24P&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20insertion%20device%20for%20the%20soft%20X-ray%20photochemistry%20beamline%20at%20SPring-8&rft.jtitle=Journal%20of%20synchrotron%20radiation&rft.au=Tanaka,%20Takashi&rft.date=1998-05-01&rft.volume=5&rft.issue=3&rft.spage=459&rft.epage=461&rft.pages=459-461&rft.issn=1600-5775&rft.eissn=1600-5775&rft_id=info:doi/10.1107/S0909049597013733&rft_dat=%3Cproquest_24P%3E817618257%3C/proquest_24P%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4943-617d4a9016cad516c81529240a1103655e791add1e857b09c39c6960765faf3e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=817618257&rft_id=info:pmid/15263545&rfr_iscdi=true |