Nitroglycerin Sublingual Tablets I: Stability of Conventional Tablets
Nitroglycerin in molded sublingual tablets volatilizes and undergoes intertablet migration. Consequently, tablets that are uniform when manufactured develop enough intertablet dose variation that they frequently fail the USP XVIII content uniformity test. Factors influencing volatilization and migra...
Saved in:
Published in: | Journal of pharmaceutical sciences 1973-01, Vol.62 (1), p.122-129 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Nitroglycerin in molded sublingual tablets volatilizes and undergoes intertablet migration. Consequently, tablets that are uniform when manufactured develop enough intertablet dose variation that they frequently fail the USP XVIII content uniformity test. Factors influencing volatilization and migration are discussed. |
---|---|
ISSN: | 0022-3549 1520-6017 |
DOI: | 10.1002/jps.2600620125 |