Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft
Among the hemodynamic factors influencing intimal hyperplasia in the anastomotic region of a vascular graft, wall shear rate is believed to be one of the most important. We would like to study the effects radial wall motion on the wall shear rate distribution in the end-to-end anastomosis model of a...
Saved in:
Published in: | Annals of biomedical engineering 1998-11, Vol.26 (6), p.955-964 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c358t-532acc481c255572412e4c58166b494502e6d8314eea69dbc9e4531c7dfbb5923 |
---|---|
cites | |
container_end_page | 964 |
container_issue | 6 |
container_start_page | 955 |
container_title | Annals of biomedical engineering |
container_volume | 26 |
creator | Rhee, K Lee, S M |
description | Among the hemodynamic factors influencing intimal hyperplasia in the anastomotic region of a vascular graft, wall shear rate is believed to be one of the most important. We would like to study the effects radial wall motion on the wall shear rate distribution in the end-to-end anastomosis model of an artery and a divergent graft. Rigid and elastic models are constructed and the wall shear rate distributions are measured along the anastomosis using photochromic flow visualization method for carotid and femoral flow waveform. The mean and peak of shear rate decrease along the divergent graft, and the decreases are more significant in the elastic model. The shear rate waves are decomposed using the Fourier transform in order to separate the effects of radial wall motion and geometry. The percentage reductions of mean wall shear rates compared to steady shear rates at mean flow are calculated, and additional 8% (carotid) and 22% (femoral) reductions are observed in the elastic models near the end of the divergent graft. Also radial wall motion decreases the amplitudes of higher harmonics of wall shear rates in the elastic models. Since radial wall motion may affect the flow field differently for different geometry, wall elasticity should be considered in studying arterial hemodynamics. |
doi_str_mv | 10.1114/1.31 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_831178121</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>70114786</sourcerecordid><originalsourceid>FETCH-LOGICAL-c358t-532acc481c255572412e4c58166b494502e6d8314eea69dbc9e4531c7dfbb5923</originalsourceid><addsrcrecordid>eNp90c9LHTEQB_BQKvap_RMKoZR6WpvJr02ORdQWhF7seclmE41kN69J9on_fWPfo0IPPQWGz3yHzCB0BuQCAPgXuGDwBm1A9KzTUsm3aEOIJp3Ukr9DJ6U8EgKgmDhGx1pxqRnfoHLlvbO14ORxNlMwET-ZGPGcakgLNsuEfUxPrbhzPuUZt2J9cHtUHpzJra06PIVScxjXP11hb6awc_neLRXvTLFrbPY-G1_P0JE3sbj3h_cU_by-urv81t3-uPl--fW2s0yo2glGjbVcgaVCiJ5yoI5boUDKkWsuCHVyUgy4c0bqabTaccHA9pMfR6EpO0Xn-9xtTr9WV-owh2JdjGZxaS1D64VeAYUmP_9X9m1xvFeywY__wMe05qX9YuiF7CWlhDf0aY9sTqVk54dtDrPJzwOQ4eVUAwzsZeiHQ9Y6zm76iw63eY3Ztu2Z6LNZbCivWUIrSiX7DZ8GmV8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>756762204</pqid></control><display><type>article</type><title>Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft</title><source>Springer Link</source><creator>Rhee, K ; Lee, S M</creator><creatorcontrib>Rhee, K ; Lee, S M</creatorcontrib><description>Among the hemodynamic factors influencing intimal hyperplasia in the anastomotic region of a vascular graft, wall shear rate is believed to be one of the most important. We would like to study the effects radial wall motion on the wall shear rate distribution in the end-to-end anastomosis model of an artery and a divergent graft. Rigid and elastic models are constructed and the wall shear rate distributions are measured along the anastomosis using photochromic flow visualization method for carotid and femoral flow waveform. The mean and peak of shear rate decrease along the divergent graft, and the decreases are more significant in the elastic model. The shear rate waves are decomposed using the Fourier transform in order to separate the effects of radial wall motion and geometry. The percentage reductions of mean wall shear rates compared to steady shear rates at mean flow are calculated, and additional 8% (carotid) and 22% (femoral) reductions are observed in the elastic models near the end of the divergent graft. Also radial wall motion decreases the amplitudes of higher harmonics of wall shear rates in the elastic models. Since radial wall motion may affect the flow field differently for different geometry, wall elasticity should be considered in studying arterial hemodynamics.</description><identifier>ISSN: 0090-6964</identifier><identifier>EISSN: 1573-9686</identifier><identifier>DOI: 10.1114/1.31</identifier><identifier>PMID: 9846934</identifier><identifier>CODEN: ABMECF</identifier><language>eng</language><publisher>New York, NY: Springer</publisher><subject>Anastomosis, Surgical ; Arteries - anatomy & histology ; Arteries - physiology ; Arteries - surgery ; Biological and medical sciences ; Biomechanical Phenomena ; Biomedical Engineering - instrumentation ; Blood ; Blood Vessel Prosthesis ; Blood Vessels - anatomy & histology ; Blood Vessels - physiology ; Blood Vessels - transplantation ; Carotid Arteries - physiology ; Elasticity ; Femoral Artery - physiology ; Fourier Analysis ; Fourier transforms ; Hemodynamics - physiology ; Humans ; Medical sciences ; Models, Cardiovascular ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels</subject><ispartof>Annals of biomedical engineering, 1998-11, Vol.26 (6), p.955-964</ispartof><rights>1999 INIST-CNRS</rights><rights>Biomedical Engineering Society 1998</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c358t-532acc481c255572412e4c58166b494502e6d8314eea69dbc9e4531c7dfbb5923</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1598226$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9846934$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rhee, K</creatorcontrib><creatorcontrib>Lee, S M</creatorcontrib><title>Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft</title><title>Annals of biomedical engineering</title><addtitle>Ann Biomed Eng</addtitle><description>Among the hemodynamic factors influencing intimal hyperplasia in the anastomotic region of a vascular graft, wall shear rate is believed to be one of the most important. We would like to study the effects radial wall motion on the wall shear rate distribution in the end-to-end anastomosis model of an artery and a divergent graft. Rigid and elastic models are constructed and the wall shear rate distributions are measured along the anastomosis using photochromic flow visualization method for carotid and femoral flow waveform. The mean and peak of shear rate decrease along the divergent graft, and the decreases are more significant in the elastic model. The shear rate waves are decomposed using the Fourier transform in order to separate the effects of radial wall motion and geometry. The percentage reductions of mean wall shear rates compared to steady shear rates at mean flow are calculated, and additional 8% (carotid) and 22% (femoral) reductions are observed in the elastic models near the end of the divergent graft. Also radial wall motion decreases the amplitudes of higher harmonics of wall shear rates in the elastic models. Since radial wall motion may affect the flow field differently for different geometry, wall elasticity should be considered in studying arterial hemodynamics.</description><subject>Anastomosis, Surgical</subject><subject>Arteries - anatomy & histology</subject><subject>Arteries - physiology</subject><subject>Arteries - surgery</subject><subject>Biological and medical sciences</subject><subject>Biomechanical Phenomena</subject><subject>Biomedical Engineering - instrumentation</subject><subject>Blood</subject><subject>Blood Vessel Prosthesis</subject><subject>Blood Vessels - anatomy & histology</subject><subject>Blood Vessels - physiology</subject><subject>Blood Vessels - transplantation</subject><subject>Carotid Arteries - physiology</subject><subject>Elasticity</subject><subject>Femoral Artery - physiology</subject><subject>Fourier Analysis</subject><subject>Fourier transforms</subject><subject>Hemodynamics - physiology</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Models, Cardiovascular</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels</subject><issn>0090-6964</issn><issn>1573-9686</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNp90c9LHTEQB_BQKvap_RMKoZR6WpvJr02ORdQWhF7seclmE41kN69J9on_fWPfo0IPPQWGz3yHzCB0BuQCAPgXuGDwBm1A9KzTUsm3aEOIJp3Ukr9DJ6U8EgKgmDhGx1pxqRnfoHLlvbO14ORxNlMwET-ZGPGcakgLNsuEfUxPrbhzPuUZt2J9cHtUHpzJra06PIVScxjXP11hb6awc_neLRXvTLFrbPY-G1_P0JE3sbj3h_cU_by-urv81t3-uPl--fW2s0yo2glGjbVcgaVCiJ5yoI5boUDKkWsuCHVyUgy4c0bqabTaccHA9pMfR6EpO0Xn-9xtTr9WV-owh2JdjGZxaS1D64VeAYUmP_9X9m1xvFeywY__wMe05qX9YuiF7CWlhDf0aY9sTqVk54dtDrPJzwOQ4eVUAwzsZeiHQ9Y6zm76iw63eY3Ztu2Z6LNZbCivWUIrSiX7DZ8GmV8</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>Rhee, K</creator><creator>Lee, S M</creator><general>Springer</general><general>Springer Nature B.V</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>H8G</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KR7</scope><scope>L6V</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>M7S</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope><scope>7X8</scope></search><sort><creationdate>19981101</creationdate><title>Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft</title><author>Rhee, K ; Lee, S M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c358t-532acc481c255572412e4c58166b494502e6d8314eea69dbc9e4531c7dfbb5923</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Anastomosis, Surgical</topic><topic>Arteries - anatomy & histology</topic><topic>Arteries - physiology</topic><topic>Arteries - surgery</topic><topic>Biological and medical sciences</topic><topic>Biomechanical Phenomena</topic><topic>Biomedical Engineering - instrumentation</topic><topic>Blood</topic><topic>Blood Vessel Prosthesis</topic><topic>Blood Vessels - anatomy & histology</topic><topic>Blood Vessels - physiology</topic><topic>Blood Vessels - transplantation</topic><topic>Carotid Arteries - physiology</topic><topic>Elasticity</topic><topic>Femoral Artery - physiology</topic><topic>Fourier Analysis</topic><topic>Fourier transforms</topic><topic>Hemodynamics - physiology</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Models, Cardiovascular</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rhee, K</creatorcontrib><creatorcontrib>Lee, S M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Civil Engineering Abstracts</collection><collection>ProQuest Engineering Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Engineering Database</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering Collection</collection><collection>MEDLINE - Academic</collection><jtitle>Annals of biomedical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rhee, K</au><au>Lee, S M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft</atitle><jtitle>Annals of biomedical engineering</jtitle><addtitle>Ann Biomed Eng</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>26</volume><issue>6</issue><spage>955</spage><epage>964</epage><pages>955-964</pages><issn>0090-6964</issn><eissn>1573-9686</eissn><coden>ABMECF</coden><abstract>Among the hemodynamic factors influencing intimal hyperplasia in the anastomotic region of a vascular graft, wall shear rate is believed to be one of the most important. We would like to study the effects radial wall motion on the wall shear rate distribution in the end-to-end anastomosis model of an artery and a divergent graft. Rigid and elastic models are constructed and the wall shear rate distributions are measured along the anastomosis using photochromic flow visualization method for carotid and femoral flow waveform. The mean and peak of shear rate decrease along the divergent graft, and the decreases are more significant in the elastic model. The shear rate waves are decomposed using the Fourier transform in order to separate the effects of radial wall motion and geometry. The percentage reductions of mean wall shear rates compared to steady shear rates at mean flow are calculated, and additional 8% (carotid) and 22% (femoral) reductions are observed in the elastic models near the end of the divergent graft. Also radial wall motion decreases the amplitudes of higher harmonics of wall shear rates in the elastic models. Since radial wall motion may affect the flow field differently for different geometry, wall elasticity should be considered in studying arterial hemodynamics.</abstract><cop>New York, NY</cop><pub>Springer</pub><pmid>9846934</pmid><doi>10.1114/1.31</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0090-6964 |
ispartof | Annals of biomedical engineering, 1998-11, Vol.26 (6), p.955-964 |
issn | 0090-6964 1573-9686 |
language | eng |
recordid | cdi_proquest_miscellaneous_831178121 |
source | Springer Link |
subjects | Anastomosis, Surgical Arteries - anatomy & histology Arteries - physiology Arteries - surgery Biological and medical sciences Biomechanical Phenomena Biomedical Engineering - instrumentation Blood Blood Vessel Prosthesis Blood Vessels - anatomy & histology Blood Vessels - physiology Blood Vessels - transplantation Carotid Arteries - physiology Elasticity Femoral Artery - physiology Fourier Analysis Fourier transforms Hemodynamics - physiology Humans Medical sciences Models, Cardiovascular Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases Vascular surgery: aorta, extremities, vena cava. Surgery of the lymphatic vessels |
title | Effects of radial wall motion and flow waveform on the wall shear rate distribution in the divergent vascular graft |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T21%3A11%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effects%20of%20radial%20wall%20motion%20and%20flow%20waveform%20on%20the%20wall%20shear%20rate%20distribution%20in%20the%20divergent%20vascular%20graft&rft.jtitle=Annals%20of%20biomedical%20engineering&rft.au=Rhee,%20K&rft.date=1998-11-01&rft.volume=26&rft.issue=6&rft.spage=955&rft.epage=964&rft.pages=955-964&rft.issn=0090-6964&rft.eissn=1573-9686&rft.coden=ABMECF&rft_id=info:doi/10.1114/1.31&rft_dat=%3Cproquest_cross%3E70114786%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c358t-532acc481c255572412e4c58166b494502e6d8314eea69dbc9e4531c7dfbb5923%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=756762204&rft_id=info:pmid/9846934&rfr_iscdi=true |