Loading…
Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital
Optimizing patient-ventilator synchrony is essential in managing patients who require prolonged mechanical ventilation in the long-term acute-care hospital. Inadequate synchrony can increase work of breathing, cause patient discomfort, and delay both weaning and general rehabilitation. Achieving opt...
Saved in:
Published in: | Respiratory care 2011-02, Vol.56 (2), p.207-213 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c462t-efdb0324be85862a05ef73c8a3a5a85f800d08f2c6afc14f3a52da1ed0b03d1b3 |
---|---|
cites | |
container_end_page | 213 |
container_issue | 2 |
container_start_page | 207 |
container_title | Respiratory care |
container_volume | 56 |
creator | GHAMLOUSH, Maher O'CONNOR, Heidi H WHITE, Alexander C |
description | Optimizing patient-ventilator synchrony is essential in managing patients who require prolonged mechanical ventilation in the long-term acute-care hospital. Inadequate synchrony can increase work of breathing, cause patient discomfort, and delay both weaning and general rehabilitation. Achieving optimal synchrony in the long-term acute-care hospital depends on a number of factors, including adjusting ventilator settings in response to improving lung function; adjusting psychotropic medications to control delirium, anxiety, and depression; and ensuring there is a well positioned correctly sized tracheostomy tube in the airway. The purpose of this review is to provide an update on issues pertinent to patient-ventilator synchrony in the LTACH setting. |
doi_str_mv | 10.4187/respcare.01084 |
format | article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_853471660</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A248404811</galeid><sourcerecordid>A248404811</sourcerecordid><originalsourceid>FETCH-LOGICAL-c462t-efdb0324be85862a05ef73c8a3a5a85f800d08f2c6afc14f3a52da1ed0b03d1b3</originalsourceid><addsrcrecordid>eNptkU1vEzEQhi0EoqFw5YhWQoXTBn_trnOMokIrRWoPhas18Y4bI68dbO-Bf49DUz6kytJYHj3vjGdeQt4yupRMDZ8S5oOBhEvKqJLPyIKtpGhF38nnZEEppy0TXJ6RVzl_r89edquX5IwzIQRTdEE2t1AchtJ-q8F5KDE116FgAlNcDI0LTdljs43hvr3DNDVrMxdsN7VlcxXzwRXwr8kLCz7jm9N9Tr5-vrzbXLXbmy_Xm_W2NbLnpUU77mj9zA5Vp3oOtEM7CKNAQAeqs4rSkSrLTQ_WMGlrmo_AcKRVNrKdOCcfH-oeUvwxYy56ctmg9xAwzlmrTsiB9T2t5PsH8h48ahdsLHWgI63XXCpJpWKsUssnqHpGnJyJAa2r-f8EH_4R7BF82efo5-Om8pOVTYo5J7T6kNwE6admVB9904--6d--VcG702jzbsLxD_5oVAUuTgBkA94mCMblv5xY8WEQK_EL9QKfjQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>853471660</pqid></control><display><type>article</type><title>Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital</title><source>Open Access: PubMed Central</source><creator>GHAMLOUSH, Maher ; O'CONNOR, Heidi H ; WHITE, Alexander C</creator><creatorcontrib>GHAMLOUSH, Maher ; O'CONNOR, Heidi H ; WHITE, Alexander C</creatorcontrib><description>Optimizing patient-ventilator synchrony is essential in managing patients who require prolonged mechanical ventilation in the long-term acute-care hospital. Inadequate synchrony can increase work of breathing, cause patient discomfort, and delay both weaning and general rehabilitation. Achieving optimal synchrony in the long-term acute-care hospital depends on a number of factors, including adjusting ventilator settings in response to improving lung function; adjusting psychotropic medications to control delirium, anxiety, and depression; and ensuring there is a well positioned correctly sized tracheostomy tube in the airway. The purpose of this review is to provide an update on issues pertinent to patient-ventilator synchrony in the LTACH setting.</description><identifier>ISSN: 0020-1324</identifier><identifier>EISSN: 1943-3654</identifier><identifier>DOI: 10.4187/respcare.01084</identifier><identifier>PMID: 21333180</identifier><identifier>CODEN: RECACP</identifier><language>eng</language><publisher>Irving, TX: Daedalus</publisher><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Anxiety - prevention & control ; Artificial respiration ; Biological and medical sciences ; Care and treatment ; Clinical death. Palliative care. Organ gift and preservation ; Delirium - prevention & control ; Depression - prevention & control ; Health aspects ; Hospital patients ; Humans ; Intensive care medicine ; Long-Term Care ; Medical sciences ; Physiological aspects ; Respiration ; Respiration, Artificial ; Respiratory Insufficiency - physiopathology ; Respiratory Insufficiency - therapy ; Risk Factors ; Tracheostomy ; Ventilator Weaning ; Ventilators, Mechanical ; Work of Breathing - physiology</subject><ispartof>Respiratory care, 2011-02, Vol.56 (2), p.207-213</ispartof><rights>2015 INIST-CNRS</rights><rights>COPYRIGHT 2011 Daedalus Enterprises, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c462t-efdb0324be85862a05ef73c8a3a5a85f800d08f2c6afc14f3a52da1ed0b03d1b3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,780,784,789,790,23928,23929,25138,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=23927739$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21333180$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>GHAMLOUSH, Maher</creatorcontrib><creatorcontrib>O'CONNOR, Heidi H</creatorcontrib><creatorcontrib>WHITE, Alexander C</creatorcontrib><title>Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital</title><title>Respiratory care</title><addtitle>Respir Care</addtitle><description>Optimizing patient-ventilator synchrony is essential in managing patients who require prolonged mechanical ventilation in the long-term acute-care hospital. Inadequate synchrony can increase work of breathing, cause patient discomfort, and delay both weaning and general rehabilitation. Achieving optimal synchrony in the long-term acute-care hospital depends on a number of factors, including adjusting ventilator settings in response to improving lung function; adjusting psychotropic medications to control delirium, anxiety, and depression; and ensuring there is a well positioned correctly sized tracheostomy tube in the airway. The purpose of this review is to provide an update on issues pertinent to patient-ventilator synchrony in the LTACH setting.</description><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Anxiety - prevention & control</subject><subject>Artificial respiration</subject><subject>Biological and medical sciences</subject><subject>Care and treatment</subject><subject>Clinical death. Palliative care. Organ gift and preservation</subject><subject>Delirium - prevention & control</subject><subject>Depression - prevention & control</subject><subject>Health aspects</subject><subject>Hospital patients</subject><subject>Humans</subject><subject>Intensive care medicine</subject><subject>Long-Term Care</subject><subject>Medical sciences</subject><subject>Physiological aspects</subject><subject>Respiration</subject><subject>Respiration, Artificial</subject><subject>Respiratory Insufficiency - physiopathology</subject><subject>Respiratory Insufficiency - therapy</subject><subject>Risk Factors</subject><subject>Tracheostomy</subject><subject>Ventilator Weaning</subject><subject>Ventilators, Mechanical</subject><subject>Work of Breathing - physiology</subject><issn>0020-1324</issn><issn>1943-3654</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNptkU1vEzEQhi0EoqFw5YhWQoXTBn_trnOMokIrRWoPhas18Y4bI68dbO-Bf49DUz6kytJYHj3vjGdeQt4yupRMDZ8S5oOBhEvKqJLPyIKtpGhF38nnZEEppy0TXJ6RVzl_r89edquX5IwzIQRTdEE2t1AchtJ-q8F5KDE116FgAlNcDI0LTdljs43hvr3DNDVrMxdsN7VlcxXzwRXwr8kLCz7jm9N9Tr5-vrzbXLXbmy_Xm_W2NbLnpUU77mj9zA5Vp3oOtEM7CKNAQAeqs4rSkSrLTQ_WMGlrmo_AcKRVNrKdOCcfH-oeUvwxYy56ctmg9xAwzlmrTsiB9T2t5PsH8h48ahdsLHWgI63XXCpJpWKsUssnqHpGnJyJAa2r-f8EH_4R7BF82efo5-Om8pOVTYo5J7T6kNwE6admVB9904--6d--VcG702jzbsLxD_5oVAUuTgBkA94mCMblv5xY8WEQK_EL9QKfjQ</recordid><startdate>20110201</startdate><enddate>20110201</enddate><creator>GHAMLOUSH, Maher</creator><creator>O'CONNOR, Heidi H</creator><creator>WHITE, Alexander C</creator><general>Daedalus</general><general>Daedalus Enterprises, Inc</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20110201</creationdate><title>Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital</title><author>GHAMLOUSH, Maher ; O'CONNOR, Heidi H ; WHITE, Alexander C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c462t-efdb0324be85862a05ef73c8a3a5a85f800d08f2c6afc14f3a52da1ed0b03d1b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Anxiety - prevention & control</topic><topic>Artificial respiration</topic><topic>Biological and medical sciences</topic><topic>Care and treatment</topic><topic>Clinical death. Palliative care. Organ gift and preservation</topic><topic>Delirium - prevention & control</topic><topic>Depression - prevention & control</topic><topic>Health aspects</topic><topic>Hospital patients</topic><topic>Humans</topic><topic>Intensive care medicine</topic><topic>Long-Term Care</topic><topic>Medical sciences</topic><topic>Physiological aspects</topic><topic>Respiration</topic><topic>Respiration, Artificial</topic><topic>Respiratory Insufficiency - physiopathology</topic><topic>Respiratory Insufficiency - therapy</topic><topic>Risk Factors</topic><topic>Tracheostomy</topic><topic>Ventilator Weaning</topic><topic>Ventilators, Mechanical</topic><topic>Work of Breathing - physiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>GHAMLOUSH, Maher</creatorcontrib><creatorcontrib>O'CONNOR, Heidi H</creatorcontrib><creatorcontrib>WHITE, Alexander C</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Respiratory care</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>GHAMLOUSH, Maher</au><au>O'CONNOR, Heidi H</au><au>WHITE, Alexander C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital</atitle><jtitle>Respiratory care</jtitle><addtitle>Respir Care</addtitle><date>2011-02-01</date><risdate>2011</risdate><volume>56</volume><issue>2</issue><spage>207</spage><epage>213</epage><pages>207-213</pages><issn>0020-1324</issn><eissn>1943-3654</eissn><coden>RECACP</coden><abstract>Optimizing patient-ventilator synchrony is essential in managing patients who require prolonged mechanical ventilation in the long-term acute-care hospital. Inadequate synchrony can increase work of breathing, cause patient discomfort, and delay both weaning and general rehabilitation. Achieving optimal synchrony in the long-term acute-care hospital depends on a number of factors, including adjusting ventilator settings in response to improving lung function; adjusting psychotropic medications to control delirium, anxiety, and depression; and ensuring there is a well positioned correctly sized tracheostomy tube in the airway. The purpose of this review is to provide an update on issues pertinent to patient-ventilator synchrony in the LTACH setting.</abstract><cop>Irving, TX</cop><pub>Daedalus</pub><pmid>21333180</pmid><doi>10.4187/respcare.01084</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0020-1324 |
ispartof | Respiratory care, 2011-02, Vol.56 (2), p.207-213 |
issn | 0020-1324 1943-3654 |
language | eng |
recordid | cdi_proquest_miscellaneous_853471660 |
source | Open Access: PubMed Central |
subjects | Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy Anxiety - prevention & control Artificial respiration Biological and medical sciences Care and treatment Clinical death. Palliative care. Organ gift and preservation Delirium - prevention & control Depression - prevention & control Health aspects Hospital patients Humans Intensive care medicine Long-Term Care Medical sciences Physiological aspects Respiration Respiration, Artificial Respiratory Insufficiency - physiopathology Respiratory Insufficiency - therapy Risk Factors Tracheostomy Ventilator Weaning Ventilators, Mechanical Work of Breathing - physiology |
title | Patient-Ventilator Interaction in the Long-Term Acute-Care Hospital |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T01%3A05%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Patient-Ventilator%20Interaction%20in%20the%20Long-Term%20Acute-Care%20Hospital&rft.jtitle=Respiratory%20care&rft.au=GHAMLOUSH,%20Maher&rft.date=2011-02-01&rft.volume=56&rft.issue=2&rft.spage=207&rft.epage=213&rft.pages=207-213&rft.issn=0020-1324&rft.eissn=1943-3654&rft.coden=RECACP&rft_id=info:doi/10.4187/respcare.01084&rft_dat=%3Cgale_proqu%3EA248404811%3C/gale_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c462t-efdb0324be85862a05ef73c8a3a5a85f800d08f2c6afc14f3a52da1ed0b03d1b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=853471660&rft_id=info:pmid/21333180&rft_galeid=A248404811&rfr_iscdi=true |