Loading…

Increasing the Internal Protection of a Pulsed Reactor Against Wrong or Illegal Actions

The physical features of fission pulse generation by a BARS-5 reactor in the "power" regime with a strong internal neutron source are described. It is shown that the pulse parameters are determined primarily by a rate of increase of reactivity, small errors in the calibration of the rods a...

Full description

Saved in:
Bibliographic Details
Published in:Atomic energy (New York, N.Y.) N.Y.), 2003-05, Vol.94 (5), p.350-354
Main Authors: Snopkov, A A, Markov, V N, Gorin, N V
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The physical features of fission pulse generation by a BARS-5 reactor in the "power" regime with a strong internal neutron source are described. It is shown that the pulse parameters are determined primarily by a rate of increase of reactivity, small errors in the calibration of the rods are negligible, safety in emergency situations, including those due to wrong or illegal actions taken by personnel, is ensured by physical factors which prevent the realization of the entire reactivity, introduced by the emergency, in a single pulse.[PUBLICATION ABSTRACT]
ISSN:1063-4258
1573-8205
DOI:10.1023/A:1025044129564