Dynamical Error in Measuring VVÉR Coolant Temperature

A computational-experimental method for predicting and estimating the dynamical error in measuring the coolant temperature in VVÉR transient regimes is examined. The method is based on thermal probing of a thermocouple by passing an electric current pulse through the thermocouple wires and detecting...

Full description

Saved in:
Bibliographic Details
Published in:Atomic energy (New York, N.Y.) N.Y.), 2003-03, Vol.94 (3), p.149-153
Main Authors: Priimak, S V, Alekseev, S V, Oleinikov, P P, Kozachenko, K S, Shapovalov, Yu L, Shikalov, V F
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A computational-experimental method for predicting and estimating the dynamical error in measuring the coolant temperature in VVÉR transient regimes is examined. The method is based on thermal probing of a thermocouple by passing an electric current pulse through the thermocouple wires and detecting and analyzing the transient characteristic using a special algorithm. The special features of the transient characteristics are investigated and an example of estimating the error is presented.[PUBLICATION ABSTRACT]