Special features of steam-gas flow through a crack in the protective envelope of a nuclear power plant

Experimental data on the escape of steam and liquid drops with the outflow of a steam-air mixture through a model of a crack in a concrete protective envelope are presented. The experiments are performed using cold and heated concrete assemblies. Complete condensation of the steam on the surface of...

Full description

Saved in:
Bibliographic Details
Published in:Atomic energy (New York, N.Y.) N.Y.), 2004-11, Vol.97 (5), p.744-749
Main Authors: Kalyakin, S G, Tsyganok, A A, Taranov, G S, Grigor'ev, M M
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Experimental data on the escape of steam and liquid drops with the outflow of a steam-air mixture through a model of a crack in a concrete protective envelope are presented. The experiments are performed using cold and heated concrete assemblies. Complete condensation of the steam on the surface of a crack occurs at relatively low temperatures of the concrete assembly. As the concrete assembly is heated, drops appear in the gas flow at the exit.[PUBLICATION ABSTRACT]
ISSN:1063-4258
1573-8205
DOI:10.1007/s10512-004-0002-8