CARTO-guided vs. NavX-guided pulmonary vein antrum isolation and pulmonary vein antrum isolation performed without 3-D mapping: effect of the 3-D mapping system on procedure duration and fluoroscopy time
Purpose Pulmonary vein antrum isolation (PVAI) guided by intracardiac echocardiography and a roaming circular mapping catheter is an effective treatment modality for atrial fibrillation. Unfortunately, the complexity of this technique leads to long procedure times and high fluoroscopy exposure. This...
Saved in:
Published in: | Journal of interventional cardiac electrophysiology 2011-04, Vol.30 (3), p.233-240 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
Pulmonary vein antrum isolation (PVAI) guided by intracardiac echocardiography and a roaming circular mapping catheter is an effective treatment modality for atrial fibrillation. Unfortunately, the complexity of this technique leads to long procedure times and high fluoroscopy exposure. This study examined the effect of two different mapping systems on the procedural characteristics and clinical outcomes of PVAI for atrial fibrillation.
Methods
Referred patients underwent PVAI using a magnetic-based 3-dimensional (3-D) mapping (CARTO® System; group 1), a current-based system (EnSite NavX™; group 2), or fluoroscopy without 3-D mapping (group 3) between February 2004 and November 2009.
Results
Data were analyzed from 71 patients in group 1, 165 patients in group 2, and 197 patients in group 3. Baseline characteristics and measured long-term outcomes did not differ between the groups. Although patients in group 1 were more likely to undergo a concurrent flutter ablation (
P
= 0.01), they had significantly shorter procedure time, fluoroscopy time, and radiofrequency energy delivery time compared with group 2 and 3 patients. No difference was detected among the groups with respect to recurrence, mean time to recurrence, or number of PVAI procedures.
Conclusions
Use of a magnetic-based 3-D mapping system, which allows precise spatial localization of the ablation catheter, was associated with significantly lower procedure time, fluoroscopy duration, and radiofrequency energy delivery time during catheter ablation for atrial fibrillation compared with a current-based system and ablation performed without 3-D mapping, although measured short- and long-term clinical outcomes were similar. |
---|---|
ISSN: | 1383-875X 1572-8595 |
DOI: | 10.1007/s10840-010-9538-9 |