Loading…

An accurate and precise polynomial model of angular interrogation surface plasmon resonance data

We present a simple, statistically based method of fitting waveguide-coupled surface plasmon resonance (WCSPR) angular interrogation experiment data in the vicinity of the resonance angle using an appropriate polynomial model. This method allows one to determine the resonance angle to within precisi...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and actuators. B, Chemical Chemical, 2011-01, Vol.151 (2), p.309-319
Main Authors: Wang, Zhiyou, Diamond, J.J., Hou, Rui, Wang, Kun, Song, Lusheng, Su, Yalin, Zheng, Zheng, Zhu, Jinsong
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3
cites cdi_FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3
container_end_page 319
container_issue 2
container_start_page 309
container_title Sensors and actuators. B, Chemical
container_volume 151
creator Wang, Zhiyou
Diamond, J.J.
Hou, Rui
Wang, Kun
Song, Lusheng
Su, Yalin
Zheng, Zheng
Zhu, Jinsong
description We present a simple, statistically based method of fitting waveguide-coupled surface plasmon resonance (WCSPR) angular interrogation experiment data in the vicinity of the resonance angle using an appropriate polynomial model. This method allows one to determine the resonance angle to within precision of as little as 2% of the sampling step size, with mean results averaging about 8% of the step size, better than an order of magnitude improvement over no regression, achieved with little effort. In testing this method, we use theoretical and experimental WCSPR data. We have compared the statistical significance of using additional terms in a given polynomial representation. F-Ratio tests based on the “extra sum of squares” principle indicate that, in the vicinity of the resonance, approximately 20 millidegrees about the minimum, the addition of quintic or higher order terms to the quartic polynomial representation is not statistically significant. We have found that both cubic and quartic models produce estimates of the position of the minimum in which the confidence interval is both accurate and precise with an error of less than one tenth of a millidegree. In addition, a similar analysis of theoretical calculations suggests that this polynomial method, which is generally applicable to the determination of extrema in any spectrum, is capable of very high accuracy and precision.
doi_str_mv 10.1016/j.snb.2010.02.055
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_864410652</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400510001760</els_id><sourcerecordid>864410652</sourcerecordid><originalsourceid>FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhi0EEqXwA5jIxpRyju2kEVOF-JIqMUBnc3EulavELnaCxL_HVZmZTnfvh3QPY9ccFhx4ebdbRNcsCkg7FAtQ6oTN-LISuYCqOmUzqAuVSwB1zi5i3AGAFCXM2OfKZWjMFHCkDF2b7QMZGynb-_7H-cFinw2-pT7zXdK3U48hs26kEPwWR-tdFqfQoUmJHuOQ9kDRO3Tp0uKIl-yswz7S1d-cs83T48fDS75-e359WK1zI5QY87JD3qAsZaOkEkuOBDVJQURNrQgKScA7gFLWoq4Mr3kSq9q0nJSCRpGYs9tj7z74r4niqAcbDfU9OvJT1MtSSg6lKpKTH50m-BgDdXof7IDhR3PQB5h6pxNMfYCpodAJZsrcHDMdeo3bYKPevCeDAuC8UuLQen90UHry21LQ0VhKFFqbiI669faf_l9Z2Ya9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>864410652</pqid></control><display><type>article</type><title>An accurate and precise polynomial model of angular interrogation surface plasmon resonance data</title><source>ScienceDirect Freedom Collection</source><creator>Wang, Zhiyou ; Diamond, J.J. ; Hou, Rui ; Wang, Kun ; Song, Lusheng ; Su, Yalin ; Zheng, Zheng ; Zhu, Jinsong</creator><creatorcontrib>Wang, Zhiyou ; Diamond, J.J. ; Hou, Rui ; Wang, Kun ; Song, Lusheng ; Su, Yalin ; Zheng, Zheng ; Zhu, Jinsong</creatorcontrib><description>We present a simple, statistically based method of fitting waveguide-coupled surface plasmon resonance (WCSPR) angular interrogation experiment data in the vicinity of the resonance angle using an appropriate polynomial model. This method allows one to determine the resonance angle to within precision of as little as 2% of the sampling step size, with mean results averaging about 8% of the step size, better than an order of magnitude improvement over no regression, achieved with little effort. In testing this method, we use theoretical and experimental WCSPR data. We have compared the statistical significance of using additional terms in a given polynomial representation. F-Ratio tests based on the “extra sum of squares” principle indicate that, in the vicinity of the resonance, approximately 20 millidegrees about the minimum, the addition of quintic or higher order terms to the quartic polynomial representation is not statistically significant. We have found that both cubic and quartic models produce estimates of the position of the minimum in which the confidence interval is both accurate and precise with an error of less than one tenth of a millidegree. In addition, a similar analysis of theoretical calculations suggests that this polynomial method, which is generally applicable to the determination of extrema in any spectrum, is capable of very high accuracy and precision.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2010.02.055</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Actuators ; Angular interrogation ; Confidence interval ; Confidence intervals ; Interrogation ; Mathematical models ; Plasmons ; Polynomial fitting ; Regression ; Regression model ; Representations ; Sampling ; Spectroscopy ; SPR ; surface plasmon resonance</subject><ispartof>Sensors and actuators. B, Chemical, 2011-01, Vol.151 (2), p.309-319</ispartof><rights>2011 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3</citedby><cites>FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27900,27901</link.rule.ids></links><search><creatorcontrib>Wang, Zhiyou</creatorcontrib><creatorcontrib>Diamond, J.J.</creatorcontrib><creatorcontrib>Hou, Rui</creatorcontrib><creatorcontrib>Wang, Kun</creatorcontrib><creatorcontrib>Song, Lusheng</creatorcontrib><creatorcontrib>Su, Yalin</creatorcontrib><creatorcontrib>Zheng, Zheng</creatorcontrib><creatorcontrib>Zhu, Jinsong</creatorcontrib><title>An accurate and precise polynomial model of angular interrogation surface plasmon resonance data</title><title>Sensors and actuators. B, Chemical</title><description>We present a simple, statistically based method of fitting waveguide-coupled surface plasmon resonance (WCSPR) angular interrogation experiment data in the vicinity of the resonance angle using an appropriate polynomial model. This method allows one to determine the resonance angle to within precision of as little as 2% of the sampling step size, with mean results averaging about 8% of the step size, better than an order of magnitude improvement over no regression, achieved with little effort. In testing this method, we use theoretical and experimental WCSPR data. We have compared the statistical significance of using additional terms in a given polynomial representation. F-Ratio tests based on the “extra sum of squares” principle indicate that, in the vicinity of the resonance, approximately 20 millidegrees about the minimum, the addition of quintic or higher order terms to the quartic polynomial representation is not statistically significant. We have found that both cubic and quartic models produce estimates of the position of the minimum in which the confidence interval is both accurate and precise with an error of less than one tenth of a millidegree. In addition, a similar analysis of theoretical calculations suggests that this polynomial method, which is generally applicable to the determination of extrema in any spectrum, is capable of very high accuracy and precision.</description><subject>Actuators</subject><subject>Angular interrogation</subject><subject>Confidence interval</subject><subject>Confidence intervals</subject><subject>Interrogation</subject><subject>Mathematical models</subject><subject>Plasmons</subject><subject>Polynomial fitting</subject><subject>Regression</subject><subject>Regression model</subject><subject>Representations</subject><subject>Sampling</subject><subject>Spectroscopy</subject><subject>SPR</subject><subject>surface plasmon resonance</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhi0EEqXwA5jIxpRyju2kEVOF-JIqMUBnc3EulavELnaCxL_HVZmZTnfvh3QPY9ccFhx4ebdbRNcsCkg7FAtQ6oTN-LISuYCqOmUzqAuVSwB1zi5i3AGAFCXM2OfKZWjMFHCkDF2b7QMZGynb-_7H-cFinw2-pT7zXdK3U48hs26kEPwWR-tdFqfQoUmJHuOQ9kDRO3Tp0uKIl-yswz7S1d-cs83T48fDS75-e359WK1zI5QY87JD3qAsZaOkEkuOBDVJQURNrQgKScA7gFLWoq4Mr3kSq9q0nJSCRpGYs9tj7z74r4niqAcbDfU9OvJT1MtSSg6lKpKTH50m-BgDdXof7IDhR3PQB5h6pxNMfYCpodAJZsrcHDMdeo3bYKPevCeDAuC8UuLQen90UHry21LQ0VhKFFqbiI669faf_l9Z2Ya9</recordid><startdate>20110128</startdate><enddate>20110128</enddate><creator>Wang, Zhiyou</creator><creator>Diamond, J.J.</creator><creator>Hou, Rui</creator><creator>Wang, Kun</creator><creator>Song, Lusheng</creator><creator>Su, Yalin</creator><creator>Zheng, Zheng</creator><creator>Zhu, Jinsong</creator><general>Elsevier B.V</general><scope>FBQ</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20110128</creationdate><title>An accurate and precise polynomial model of angular interrogation surface plasmon resonance data</title><author>Wang, Zhiyou ; Diamond, J.J. ; Hou, Rui ; Wang, Kun ; Song, Lusheng ; Su, Yalin ; Zheng, Zheng ; Zhu, Jinsong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Actuators</topic><topic>Angular interrogation</topic><topic>Confidence interval</topic><topic>Confidence intervals</topic><topic>Interrogation</topic><topic>Mathematical models</topic><topic>Plasmons</topic><topic>Polynomial fitting</topic><topic>Regression</topic><topic>Regression model</topic><topic>Representations</topic><topic>Sampling</topic><topic>Spectroscopy</topic><topic>SPR</topic><topic>surface plasmon resonance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Zhiyou</creatorcontrib><creatorcontrib>Diamond, J.J.</creatorcontrib><creatorcontrib>Hou, Rui</creatorcontrib><creatorcontrib>Wang, Kun</creatorcontrib><creatorcontrib>Song, Lusheng</creatorcontrib><creatorcontrib>Su, Yalin</creatorcontrib><creatorcontrib>Zheng, Zheng</creatorcontrib><creatorcontrib>Zhu, Jinsong</creatorcontrib><collection>AGRIS</collection><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Zhiyou</au><au>Diamond, J.J.</au><au>Hou, Rui</au><au>Wang, Kun</au><au>Song, Lusheng</au><au>Su, Yalin</au><au>Zheng, Zheng</au><au>Zhu, Jinsong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An accurate and precise polynomial model of angular interrogation surface plasmon resonance data</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2011-01-28</date><risdate>2011</risdate><volume>151</volume><issue>2</issue><spage>309</spage><epage>319</epage><pages>309-319</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>We present a simple, statistically based method of fitting waveguide-coupled surface plasmon resonance (WCSPR) angular interrogation experiment data in the vicinity of the resonance angle using an appropriate polynomial model. This method allows one to determine the resonance angle to within precision of as little as 2% of the sampling step size, with mean results averaging about 8% of the step size, better than an order of magnitude improvement over no regression, achieved with little effort. In testing this method, we use theoretical and experimental WCSPR data. We have compared the statistical significance of using additional terms in a given polynomial representation. F-Ratio tests based on the “extra sum of squares” principle indicate that, in the vicinity of the resonance, approximately 20 millidegrees about the minimum, the addition of quintic or higher order terms to the quartic polynomial representation is not statistically significant. We have found that both cubic and quartic models produce estimates of the position of the minimum in which the confidence interval is both accurate and precise with an error of less than one tenth of a millidegree. In addition, a similar analysis of theoretical calculations suggests that this polynomial method, which is generally applicable to the determination of extrema in any spectrum, is capable of very high accuracy and precision.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2010.02.055</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2011-01, Vol.151 (2), p.309-319
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_miscellaneous_864410652
source ScienceDirect Freedom Collection
subjects Actuators
Angular interrogation
Confidence interval
Confidence intervals
Interrogation
Mathematical models
Plasmons
Polynomial fitting
Regression
Regression model
Representations
Sampling
Spectroscopy
SPR
surface plasmon resonance
title An accurate and precise polynomial model of angular interrogation surface plasmon resonance data
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-25T12%3A49%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20accurate%20and%20precise%20polynomial%20model%20of%20angular%20interrogation%20surface%20plasmon%20resonance%20data&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Wang,%20Zhiyou&rft.date=2011-01-28&rft.volume=151&rft.issue=2&rft.spage=309&rft.epage=319&rft.pages=309-319&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2010.02.055&rft_dat=%3Cproquest_cross%3E864410652%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c353t-6fa1ba464b545381ae09e43eeeb95e024e01f00649397c191e4379cd1e550b5e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=864410652&rft_id=info:pmid/&rfr_iscdi=true