Loading…

Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy

Saved in:
Bibliographic Details
Published in:European journal of cardio-thoracic surgery 2011-07, Vol.40 (1), p.269-269
Main Authors: Yu, Lei, Shi, Enyi, Gu, Tianxiang
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c418t-24e68e5c23df50b41482c5e461e2e0ebb179a5b14bc93ea7369f4318882223023
cites
container_end_page 269
container_issue 1
container_start_page 269
container_title European journal of cardio-thoracic surgery
container_volume 40
creator Yu, Lei
Shi, Enyi
Gu, Tianxiang
description
doi_str_mv 10.1016/j.ejcts.2010.11.009
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_871382169</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1016/j.ejcts.2010.11.009</oup_id><sourcerecordid>871382169</sourcerecordid><originalsourceid>FETCH-LOGICAL-c418t-24e68e5c23df50b41482c5e461e2e0ebb179a5b14bc93ea7369f4318882223023</originalsourceid><addsrcrecordid>eNqNkE1PxCAQhonRuOvHLzAxvRhPrQzQQo_G-JWYeNHEG6F0qt30S6CH_fey7qpXT5DheWeGh5AzoBlQKK5WGa5s8BmjmwpklJZ7ZAlK8lRy8bYf7_EllaWgC3Lk_YpSWnAmD8mCARRSsnxJXu5bM4TEYXCjD-gG0yWTx7keUzPg7Na-T8YmCR-YGG9xqNvhPTGjCybpTIjFJoaSCV1rjatbtGHs1yfkoDGdx9PdeUxe725fbh7Sp-f7x5vrp9QKUCFlAguFuWW8bnJaCRCK2RxFAciQYlWBLE1egahsydFIXpSN4KCUYoxxyvgxudz2ndz4OaMPum_jkl0XVx9nr5UErhgUZST5lrTxm95hoyfX9satNVC9salX-tum3tjUADrajKnzXf-56rH-zfzoi8DFDohyTNc4M9jW_3GClbIQm0bZlhvn6V-TvwBZyo4S</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>871382169</pqid></control><display><type>article</type><title>Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy</title><source>Oxford Journals Online</source><creator>Yu, Lei ; Shi, Enyi ; Gu, Tianxiang</creator><creatorcontrib>Yu, Lei ; Shi, Enyi ; Gu, Tianxiang</creatorcontrib><identifier>ISSN: 1010-7940</identifier><identifier>EISSN: 1873-734X</identifier><identifier>DOI: 10.1016/j.ejcts.2010.11.009</identifier><identifier>PMID: 21167725</identifier><identifier>CODEN: EJCSE7</identifier><language>eng</language><publisher>Oxford: Elsevier Science B.V</publisher><subject>Aneurysm, False - diagnostic imaging ; Aneurysm, False - etiology ; Aneurysm, False - surgery ; Aortic Aneurysm - diagnostic imaging ; Aortic Aneurysm - etiology ; Aortic Aneurysm - surgery ; Biological and medical sciences ; Cardiology. Vascular system ; Humans ; Male ; Medical sciences ; Middle Aged ; Pericardiectomy - adverse effects ; Pericardium - transplantation ; Pneumology ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the heart ; Tomography, X-Ray Computed</subject><ispartof>European journal of cardio-thoracic surgery, 2011-07, Vol.40 (1), p.269-269</ispartof><rights>European Association for Cardio-Thoracic Surgery 2011</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c418t-24e68e5c23df50b41482c5e461e2e0ebb179a5b14bc93ea7369f4318882223023</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=24297649$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21167725$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yu, Lei</creatorcontrib><creatorcontrib>Shi, Enyi</creatorcontrib><creatorcontrib>Gu, Tianxiang</creatorcontrib><title>Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy</title><title>European journal of cardio-thoracic surgery</title><addtitle>Eur J Cardiothorac Surg</addtitle><addtitle>Eur J Cardiothorac Surg</addtitle><subject>Aneurysm, False - diagnostic imaging</subject><subject>Aneurysm, False - etiology</subject><subject>Aneurysm, False - surgery</subject><subject>Aortic Aneurysm - diagnostic imaging</subject><subject>Aortic Aneurysm - etiology</subject><subject>Aortic Aneurysm - surgery</subject><subject>Biological and medical sciences</subject><subject>Cardiology. Vascular system</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Pericardiectomy - adverse effects</subject><subject>Pericardium - transplantation</subject><subject>Pneumology</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the heart</subject><subject>Tomography, X-Ray Computed</subject><issn>1010-7940</issn><issn>1873-734X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqNkE1PxCAQhonRuOvHLzAxvRhPrQzQQo_G-JWYeNHEG6F0qt30S6CH_fey7qpXT5DheWeGh5AzoBlQKK5WGa5s8BmjmwpklJZ7ZAlK8lRy8bYf7_EllaWgC3Lk_YpSWnAmD8mCARRSsnxJXu5bM4TEYXCjD-gG0yWTx7keUzPg7Na-T8YmCR-YGG9xqNvhPTGjCybpTIjFJoaSCV1rjatbtGHs1yfkoDGdx9PdeUxe725fbh7Sp-f7x5vrp9QKUCFlAguFuWW8bnJaCRCK2RxFAciQYlWBLE1egahsydFIXpSN4KCUYoxxyvgxudz2ndz4OaMPum_jkl0XVx9nr5UErhgUZST5lrTxm95hoyfX9satNVC9salX-tum3tjUADrajKnzXf-56rH-zfzoi8DFDohyTNc4M9jW_3GClbIQm0bZlhvn6V-TvwBZyo4S</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>Yu, Lei</creator><creator>Shi, Enyi</creator><creator>Gu, Tianxiang</creator><general>Elsevier Science B.V</general><general>Oxford University Press</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20110701</creationdate><title>Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy</title><author>Yu, Lei ; Shi, Enyi ; Gu, Tianxiang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c418t-24e68e5c23df50b41482c5e461e2e0ebb179a5b14bc93ea7369f4318882223023</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Aneurysm, False - diagnostic imaging</topic><topic>Aneurysm, False - etiology</topic><topic>Aneurysm, False - surgery</topic><topic>Aortic Aneurysm - diagnostic imaging</topic><topic>Aortic Aneurysm - etiology</topic><topic>Aortic Aneurysm - surgery</topic><topic>Biological and medical sciences</topic><topic>Cardiology. Vascular system</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Pericardiectomy - adverse effects</topic><topic>Pericardium - transplantation</topic><topic>Pneumology</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the heart</topic><topic>Tomography, X-Ray Computed</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yu, Lei</creatorcontrib><creatorcontrib>Shi, Enyi</creatorcontrib><creatorcontrib>Gu, Tianxiang</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of cardio-thoracic surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yu, Lei</au><au>Shi, Enyi</au><au>Gu, Tianxiang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy</atitle><jtitle>European journal of cardio-thoracic surgery</jtitle><stitle>Eur J Cardiothorac Surg</stitle><addtitle>Eur J Cardiothorac Surg</addtitle><date>2011-07-01</date><risdate>2011</risdate><volume>40</volume><issue>1</issue><spage>269</spage><epage>269</epage><pages>269-269</pages><issn>1010-7940</issn><eissn>1873-734X</eissn><coden>EJCSE7</coden><cop>Oxford</cop><pub>Elsevier Science B.V</pub><pmid>21167725</pmid><doi>10.1016/j.ejcts.2010.11.009</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1010-7940
ispartof European journal of cardio-thoracic surgery, 2011-07, Vol.40 (1), p.269-269
issn 1010-7940
1873-734X
language eng
recordid cdi_proquest_miscellaneous_871382169
source Oxford Journals Online
subjects Aneurysm, False - diagnostic imaging
Aneurysm, False - etiology
Aneurysm, False - surgery
Aortic Aneurysm - diagnostic imaging
Aortic Aneurysm - etiology
Aortic Aneurysm - surgery
Biological and medical sciences
Cardiology. Vascular system
Humans
Male
Medical sciences
Middle Aged
Pericardiectomy - adverse effects
Pericardium - transplantation
Pneumology
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the heart
Tomography, X-Ray Computed
title Giant retrosternal pseudo-aneurysm of the ascending aorta late after pericardiectomy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T05%3A53%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Giant%20retrosternal%20pseudo-aneurysm%20of%20the%20ascending%20aorta%20late%20after%20pericardiectomy&rft.jtitle=European%20journal%20of%20cardio-thoracic%20surgery&rft.au=Yu,%20Lei&rft.date=2011-07-01&rft.volume=40&rft.issue=1&rft.spage=269&rft.epage=269&rft.pages=269-269&rft.issn=1010-7940&rft.eissn=1873-734X&rft.coden=EJCSE7&rft_id=info:doi/10.1016/j.ejcts.2010.11.009&rft_dat=%3Cproquest_cross%3E871382169%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c418t-24e68e5c23df50b41482c5e461e2e0ebb179a5b14bc93ea7369f4318882223023%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=871382169&rft_id=info:pmid/21167725&rft_oup_id=10.1016/j.ejcts.2010.11.009&rfr_iscdi=true