Loading…

Correlation between the Elecsys HBsAg II assay and the Architect assay for the quantification of hepatitis B surface antigen (HBsAg) in the serum

Abstract Background Hepatitis B surface antigen (HBsAg) clearance during chronic hepatitis B (CHB) infection is associated with improved long-term clinical outcome, so is considered an important therapeutic goal in CHB. Studies have shown that serum HBsAg quantification during, and at end of, treatm...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical virology 2011-04, Vol.50 (4), p.292-296
Main Authors: Wursthorn, Karsten, Jaroszewicz, Jerzy, Zacher, Behrend J, Darnedde, Martina, Raupach, Regina, Mederacke, Ingmar, Cornberg, Markus, Manns, Michael P, Wedemeyer, Heiner
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Hepatitis B surface antigen (HBsAg) clearance during chronic hepatitis B (CHB) infection is associated with improved long-term clinical outcome, so is considered an important therapeutic goal in CHB. Studies have shown that serum HBsAg quantification during, and at end of, treatment may predict long-term HBsAg loss. Objectives Performance comparison of the qualitative Elecsys HBsAg II assay using a quantitative research protocol and an established quantitative HBsAg assay. Study design A dilution algorithm was developed for the Elecsys HBsAg II assay to allow quantification of HBsAg levels; this was used to measure HBsAg levels in a range of samples including sera from patients infected with different HBV genotypes, HBV mutants, and longitudinal samples from patients undergoing antiviral treatment. Results were compared with those from the quantitative Architect HBsAg assay. Results There was significant overall correlation between Elecsys and Architect assays (correlation coefficient [ r ] = 0.97; p < 0.001). HBsAg levels measured with both assays correlated well in all phases of infection ( r = 0.80–0.96), across all genotypes tested (HBV genotype A, r = 0.89; HBV genotype D, r = 0.97), and in samples with lamivudine-resistant mutations ( r = 0.94). Bland–Altman analysis showed only minor discordance between assays in different phases of chronic HBV-infection (3.8–5.1%). This strong correlation was also present for sera with lower HBsAg concentrations. On-treatment HBsAg levels were similar when measured with either assay. Conclusions Using a simple dilution algorithm, the quantitative Elecsys HBsAg II assay reliably determined serum HBsAg levels in a wide range of samples, and showed very high correlation with the Architect HBsAg assay.
ISSN:1386-6532
1873-5967
DOI:10.1016/j.jcv.2010.12.008