Flow-mediated dilatation of the brachial artery is a poorly reproducible indicator of microvascular function in Type I diabetes mellitus
Background: Flow-mediated dilatation (FMD) of the brachial artery is commonly measured as a surrogate marker of endothelial function. Its measurement is, however, technically demanding and reports regarding its reproducibility have not always been favourable. Aim: Two Type I diabetes and control gro...
Saved in:
Published in: | QJM : An International Journal of Medicine 2011-07, Vol.104 (7), p.589-597 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background: Flow-mediated dilatation (FMD) of the brachial artery is commonly measured as a surrogate marker of endothelial function. Its measurement is, however, technically demanding and reports regarding its reproducibility have not always been favourable.
Aim: Two Type I diabetes and control group comparator studies were conducted to assess the reproducibility of FMD and to analyse blood flow data normally discarded during FMD measurement.
Design: The studies were sequential and differed only with regard to operator and ultrasound machine. Seventy-two subjects with diabetes and 71 controls were studied in total.
Methods: Subjects had FMD measured conventionally. Blood velocity waveforms were averaged over 10 pulses post forearm ischaemia and their component frequencies analysed using the wavelet transform, a mathematical tool for waveform analysis. The component frequencies were grouped into 11 bands to facilitate analysis.
Results: Subjects were well-matched between studies. In Study 1, FMD was significantly impaired in subjects with Type I diabetes vs. controls (median 4.35%, interquartile range 3.10-4.80 vs. 6.50, 4.79-9.42, P |
---|---|