Loading…
Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution
We have examined p-tert-butylcalix[4]arenetetrathiolate (BCAT) monolayers for their potential use as molecular recognition elements for in situ aqueous chemical sensors. Spectroscopic and wetting studies of BCAT monolayers on Au{111} reveal that the calixarene molecules exist in monolayers, preferen...
Saved in:
Published in: | Analytical chemistry (Washington) 1999-01, Vol.71 (1), p.142-148 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3 |
---|---|
cites | cdi_FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3 |
container_end_page | 148 |
container_issue | 1 |
container_start_page | 142 |
container_title | Analytical chemistry (Washington) |
container_volume | 71 |
creator | Cygan, M. T Collins, G. E Dunbar, T. D Allara, D. L Gibbs, C. G Gutsche, C. D |
description | We have examined p-tert-butylcalix[4]arenetetrathiolate (BCAT) monolayers for their potential use as molecular recognition elements for in situ aqueous chemical sensors. Spectroscopic and wetting studies of BCAT monolayers on Au{111} reveal that the calixarene molecules exist in monolayers, preferentially oriented with their phenyl rings parallel to the surface normal axis. Using quartz crystal microbalance (QCM) sensors with gold-coated electrodes, the chemical specificity of monolayers and thin films to a variety of aromatic and aliphatic analytes in aqueous solution was examined. The response of BCAT sensors was compared to the responses of p-tert-butylcalix[4]arene (BCA)- and decanethiolate (DT)-coated QCM electrodes. BCAT is very selective for alkylbenzenes, much more so than either its spray-coated thin-film analogue, BCA, or the highly ordered DT monolayer. From these measurements, the factors behind molecular differentiation in each film are explored. Drawing upon these findings, the roles of cavitation and film order in molecular recognition for calixarene films are discussed. |
doi_str_mv | 10.1021/ac980659b |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_872527360</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>38839590</sourcerecordid><originalsourceid>FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3</originalsourceid><addsrcrecordid>eNpl0EtvEzEUBWALgWgoLPgDyEIgxGLg2h4_ZllFDUU04pEixMq6mbGRy8RT7Bmp4dfjNiGVYOWFPx2dewh5yuANA87eYtsYULJZ3yMzJjlUyhh-n8wAQFRcAxyRRzlfAjAGTD0kR5wpxRuhZuT7HPtwjclFR5dDHHrcupQpZvp5wjT-pvO0zSP2dBnaNKyxx9g6unIxh_iDnvZu4-KYaYj05NfkhinT1dBPYxjiY_LAY5_dk_17TL4uTi_mZ9X5x3fv5yfnFdaNHKsOQTsAX8sOGWu6tTYtGGG4r_3tWQIkA9TQ8Np30vmuFi16j8Y3UgovjsmrXe5VGkqFPNpNyK3rS9ObPtZoLrkWCop8_o-8HKYUSznLmTYaBDcFvd6hcm7OyXl7lcIG09YysDdr28PaxT7bB07rjesO8u-8BbzYA8wt9j6V9UK-SywpUvPCqh0LeXTXh29MP63SQkt78Wll1ZeFgG-LD3ZZ_Mudxzbf3fB_vz_m_KF1</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217870328</pqid></control><display><type>article</type><title>Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Cygan, M. T ; Collins, G. E ; Dunbar, T. D ; Allara, D. L ; Gibbs, C. G ; Gutsche, C. D</creator><creatorcontrib>Cygan, M. T ; Collins, G. E ; Dunbar, T. D ; Allara, D. L ; Gibbs, C. G ; Gutsche, C. D</creatorcontrib><description>We have examined p-tert-butylcalix[4]arenetetrathiolate (BCAT) monolayers for their potential use as molecular recognition elements for in situ aqueous chemical sensors. Spectroscopic and wetting studies of BCAT monolayers on Au{111} reveal that the calixarene molecules exist in monolayers, preferentially oriented with their phenyl rings parallel to the surface normal axis. Using quartz crystal microbalance (QCM) sensors with gold-coated electrodes, the chemical specificity of monolayers and thin films to a variety of aromatic and aliphatic analytes in aqueous solution was examined. The response of BCAT sensors was compared to the responses of p-tert-butylcalix[4]arene (BCA)- and decanethiolate (DT)-coated QCM electrodes. BCAT is very selective for alkylbenzenes, much more so than either its spray-coated thin-film analogue, BCA, or the highly ordered DT monolayer. From these measurements, the factors behind molecular differentiation in each film are explored. Drawing upon these findings, the roles of cavitation and film order in molecular recognition for calixarene films are discussed.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac980659b</identifier><identifier>PMID: 21662936</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemicals ; Chemistry ; Exact sciences and technology ; General, instrumentation ; Sensors</subject><ispartof>Analytical chemistry (Washington), 1999-01, Vol.71 (1), p.142-148</ispartof><rights>Copyright © 1999 American Chemical Society</rights><rights>1999 INIST-CNRS</rights><rights>Copyright American Chemical Society Jan 1, 1999</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3</citedby><cites>FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1659572$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21662936$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cygan, M. T</creatorcontrib><creatorcontrib>Collins, G. E</creatorcontrib><creatorcontrib>Dunbar, T. D</creatorcontrib><creatorcontrib>Allara, D. L</creatorcontrib><creatorcontrib>Gibbs, C. G</creatorcontrib><creatorcontrib>Gutsche, C. D</creatorcontrib><title>Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>We have examined p-tert-butylcalix[4]arenetetrathiolate (BCAT) monolayers for their potential use as molecular recognition elements for in situ aqueous chemical sensors. Spectroscopic and wetting studies of BCAT monolayers on Au{111} reveal that the calixarene molecules exist in monolayers, preferentially oriented with their phenyl rings parallel to the surface normal axis. Using quartz crystal microbalance (QCM) sensors with gold-coated electrodes, the chemical specificity of monolayers and thin films to a variety of aromatic and aliphatic analytes in aqueous solution was examined. The response of BCAT sensors was compared to the responses of p-tert-butylcalix[4]arene (BCA)- and decanethiolate (DT)-coated QCM electrodes. BCAT is very selective for alkylbenzenes, much more so than either its spray-coated thin-film analogue, BCA, or the highly ordered DT monolayer. From these measurements, the factors behind molecular differentiation in each film are explored. Drawing upon these findings, the roles of cavitation and film order in molecular recognition for calixarene films are discussed.</description><subject>Analytical chemistry</subject><subject>Chemicals</subject><subject>Chemistry</subject><subject>Exact sciences and technology</subject><subject>General, instrumentation</subject><subject>Sensors</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNpl0EtvEzEUBWALgWgoLPgDyEIgxGLg2h4_ZllFDUU04pEixMq6mbGRy8RT7Bmp4dfjNiGVYOWFPx2dewh5yuANA87eYtsYULJZ3yMzJjlUyhh-n8wAQFRcAxyRRzlfAjAGTD0kR5wpxRuhZuT7HPtwjclFR5dDHHrcupQpZvp5wjT-pvO0zSP2dBnaNKyxx9g6unIxh_iDnvZu4-KYaYj05NfkhinT1dBPYxjiY_LAY5_dk_17TL4uTi_mZ9X5x3fv5yfnFdaNHKsOQTsAX8sOGWu6tTYtGGG4r_3tWQIkA9TQ8Np30vmuFi16j8Y3UgovjsmrXe5VGkqFPNpNyK3rS9ObPtZoLrkWCop8_o-8HKYUSznLmTYaBDcFvd6hcm7OyXl7lcIG09YysDdr28PaxT7bB07rjesO8u-8BbzYA8wt9j6V9UK-SywpUvPCqh0LeXTXh29MP63SQkt78Wll1ZeFgG-LD3ZZ_Mudxzbf3fB_vz_m_KF1</recordid><startdate>19990101</startdate><enddate>19990101</enddate><creator>Cygan, M. T</creator><creator>Collins, G. E</creator><creator>Dunbar, T. D</creator><creator>Allara, D. L</creator><creator>Gibbs, C. G</creator><creator>Gutsche, C. D</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>19990101</creationdate><title>Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution</title><author>Cygan, M. T ; Collins, G. E ; Dunbar, T. D ; Allara, D. L ; Gibbs, C. G ; Gutsche, C. D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Analytical chemistry</topic><topic>Chemicals</topic><topic>Chemistry</topic><topic>Exact sciences and technology</topic><topic>General, instrumentation</topic><topic>Sensors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cygan, M. T</creatorcontrib><creatorcontrib>Collins, G. E</creatorcontrib><creatorcontrib>Dunbar, T. D</creatorcontrib><creatorcontrib>Allara, D. L</creatorcontrib><creatorcontrib>Gibbs, C. G</creatorcontrib><creatorcontrib>Gutsche, C. D</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cygan, M. T</au><au>Collins, G. E</au><au>Dunbar, T. D</au><au>Allara, D. L</au><au>Gibbs, C. G</au><au>Gutsche, C. D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>1999-01-01</date><risdate>1999</risdate><volume>71</volume><issue>1</issue><spage>142</spage><epage>148</epage><pages>142-148</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>We have examined p-tert-butylcalix[4]arenetetrathiolate (BCAT) monolayers for their potential use as molecular recognition elements for in situ aqueous chemical sensors. Spectroscopic and wetting studies of BCAT monolayers on Au{111} reveal that the calixarene molecules exist in monolayers, preferentially oriented with their phenyl rings parallel to the surface normal axis. Using quartz crystal microbalance (QCM) sensors with gold-coated electrodes, the chemical specificity of monolayers and thin films to a variety of aromatic and aliphatic analytes in aqueous solution was examined. The response of BCAT sensors was compared to the responses of p-tert-butylcalix[4]arene (BCA)- and decanethiolate (DT)-coated QCM electrodes. BCAT is very selective for alkylbenzenes, much more so than either its spray-coated thin-film analogue, BCA, or the highly ordered DT monolayer. From these measurements, the factors behind molecular differentiation in each film are explored. Drawing upon these findings, the roles of cavitation and film order in molecular recognition for calixarene films are discussed.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>21662936</pmid><doi>10.1021/ac980659b</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 1999-01, Vol.71 (1), p.142-148 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_872527360 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Analytical chemistry Chemicals Chemistry Exact sciences and technology General, instrumentation Sensors |
title | Calixarene Monolayers as Quartz Crystal Microbalance Sensing Elements in Aqueous Solution |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T16%3A47%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calixarene%20Monolayers%20as%20Quartz%20Crystal%20Microbalance%20Sensing%20Elements%20in%20Aqueous%20Solution&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Cygan,%20M.%20T&rft.date=1999-01-01&rft.volume=71&rft.issue=1&rft.spage=142&rft.epage=148&rft.pages=142-148&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac980659b&rft_dat=%3Cproquest_cross%3E38839590%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a495t-da07e00f45da119db78c08382f4fc980630510a70924fd5efd43caffa8f9553f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=217870328&rft_id=info:pmid/21662936&rfr_iscdi=true |