Loading…

Realignment capability of the nCPMG sequence

[Display omitted] ► The nCPMG sequence aims at phase insensitive generation of a long train of echoes. ► The magnetization it generates presents a symmetry property in the frequency domain. ► This is taken advantage of to determine an inverse sequence. ► A realignment of any type of magnetization at...

Full description

Saved in:
Bibliographic Details
Published in:Journal of magnetic resonance (1997) 2011-08, Vol.211 (2), p.121-133
Main Authors: Le Roux, P., McKinnon, G., Yen, Y.-F., Fernandez, B.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763
cites cdi_FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763
container_end_page 133
container_issue 2
container_start_page 121
container_title Journal of magnetic resonance (1997)
container_volume 211
creator Le Roux, P.
McKinnon, G.
Yen, Y.-F.
Fernandez, B.
description [Display omitted] ► The nCPMG sequence aims at phase insensitive generation of a long train of echoes. ► The magnetization it generates presents a symmetry property in the frequency domain. ► This is taken advantage of to determine an inverse sequence. ► A realignment of any type of magnetization at the last echo time is then possible. ► An experimental verification of this claim is presented here. The nCPMG sequence is based on a particular phase modulation of the refocusing pulse train, and was originally designed for rendering the spin echo amplitude insensitive to the initial magnetization phase. This pulse sequence has the peculiarity of being easily invertible, which enables perfect driven equilibrium experiments, in the absence of relaxation. This magnetization ‘realignment’ is effective for all three components. Hence the overall operation is transparent. Supporting theory is presented here, together with the first direct experimental proof of the claim. The experiment shows that, with the present stabilization sequence, perfect realignment is indeed made possible for a range of refocusing pulse nutation angles from 130° to 230°.
doi_str_mv 10.1016/j.jmr.2011.05.005
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_879103529</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1090780711001625</els_id><sourcerecordid>879103529</sourcerecordid><originalsourceid>FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763</originalsourceid><addsrcrecordid>eNp9kE1LxDAURYMojo7-ADfSnS5sfa9t0gZXMugoKIroOqTpi2box9h0BP-9GUddunp3ce59cBg7QkgQUJwvkkU7JCkgJsATAL7F9hCkiKHkYvs7Q1yUUEzYvvcLCCAvYJdNUhQ5pjnfY2dPpBv32rXUjZHRS125xo2fUW-j8Y2ibvZ4P488va-oM3TAdqxuPB3-3Cl7ub56nt3Edw_z29nlXWyyko9xVZPIJBJPy9roymoyFnPShc1kXqUGua0l2sLWwEmiFFxnBvIqs5wqKEQ2ZSeb3eXQh89-VK3zhppGd9SvvCoLiZDxVAby9F8SUyGKXMq0DChuUDP03g9k1XJwrR4-FYJa61QLFXSqtU4FXAWdoXP8M7-qWqr_Gr_-AnCxASjo-HA0KG_cWlXtBjKjqnv3z_wXbsaEQg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1266749928</pqid></control><display><type>article</type><title>Realignment capability of the nCPMG sequence</title><source>ScienceDirect Journals</source><creator>Le Roux, P. ; McKinnon, G. ; Yen, Y.-F. ; Fernandez, B.</creator><creatorcontrib>Le Roux, P. ; McKinnon, G. ; Yen, Y.-F. ; Fernandez, B.</creatorcontrib><description>[Display omitted] ► The nCPMG sequence aims at phase insensitive generation of a long train of echoes. ► The magnetization it generates presents a symmetry property in the frequency domain. ► This is taken advantage of to determine an inverse sequence. ► A realignment of any type of magnetization at the last echo time is then possible. ► An experimental verification of this claim is presented here. The nCPMG sequence is based on a particular phase modulation of the refocusing pulse train, and was originally designed for rendering the spin echo amplitude insensitive to the initial magnetization phase. This pulse sequence has the peculiarity of being easily invertible, which enables perfect driven equilibrium experiments, in the absence of relaxation. This magnetization ‘realignment’ is effective for all three components. Hence the overall operation is transparent. Supporting theory is presented here, together with the first direct experimental proof of the claim. The experiment shows that, with the present stabilization sequence, perfect realignment is indeed made possible for a range of refocusing pulse nutation angles from 130° to 230°.</description><identifier>ISSN: 1090-7807</identifier><identifier>EISSN: 1096-0856</identifier><identifier>DOI: 10.1016/j.jmr.2011.05.005</identifier><identifier>PMID: 21641245</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Algorithms ; Amplitudes ; Carr–Purcell–Meiboom–Gill (CPMG) ; Driven equilibrium Fourier transform (DEFT) ; Electromagnetic Fields ; Electron Spin Resonance Spectroscopy - methods ; Indicators and Reagents ; Magnetization ; MLEV ; nCPMG ; Nutation ; Phase modulation ; Realignment ; Rendering ; Shinnar–LeRoux ; Signal Processing, Computer-Assisted ; Stabilization ; Trains</subject><ispartof>Journal of magnetic resonance (1997), 2011-08, Vol.211 (2), p.121-133</ispartof><rights>2011 Elsevier Inc.</rights><rights>Copyright © 2011 Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763</citedby><cites>FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21641245$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Le Roux, P.</creatorcontrib><creatorcontrib>McKinnon, G.</creatorcontrib><creatorcontrib>Yen, Y.-F.</creatorcontrib><creatorcontrib>Fernandez, B.</creatorcontrib><title>Realignment capability of the nCPMG sequence</title><title>Journal of magnetic resonance (1997)</title><addtitle>J Magn Reson</addtitle><description>[Display omitted] ► The nCPMG sequence aims at phase insensitive generation of a long train of echoes. ► The magnetization it generates presents a symmetry property in the frequency domain. ► This is taken advantage of to determine an inverse sequence. ► A realignment of any type of magnetization at the last echo time is then possible. ► An experimental verification of this claim is presented here. The nCPMG sequence is based on a particular phase modulation of the refocusing pulse train, and was originally designed for rendering the spin echo amplitude insensitive to the initial magnetization phase. This pulse sequence has the peculiarity of being easily invertible, which enables perfect driven equilibrium experiments, in the absence of relaxation. This magnetization ‘realignment’ is effective for all three components. Hence the overall operation is transparent. Supporting theory is presented here, together with the first direct experimental proof of the claim. The experiment shows that, with the present stabilization sequence, perfect realignment is indeed made possible for a range of refocusing pulse nutation angles from 130° to 230°.</description><subject>Algorithms</subject><subject>Amplitudes</subject><subject>Carr–Purcell–Meiboom–Gill (CPMG)</subject><subject>Driven equilibrium Fourier transform (DEFT)</subject><subject>Electromagnetic Fields</subject><subject>Electron Spin Resonance Spectroscopy - methods</subject><subject>Indicators and Reagents</subject><subject>Magnetization</subject><subject>MLEV</subject><subject>nCPMG</subject><subject>Nutation</subject><subject>Phase modulation</subject><subject>Realignment</subject><subject>Rendering</subject><subject>Shinnar–LeRoux</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Stabilization</subject><subject>Trains</subject><issn>1090-7807</issn><issn>1096-0856</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAURYMojo7-ADfSnS5sfa9t0gZXMugoKIroOqTpi2box9h0BP-9GUddunp3ce59cBg7QkgQUJwvkkU7JCkgJsATAL7F9hCkiKHkYvs7Q1yUUEzYvvcLCCAvYJdNUhQ5pjnfY2dPpBv32rXUjZHRS125xo2fUW-j8Y2ibvZ4P488va-oM3TAdqxuPB3-3Cl7ub56nt3Edw_z29nlXWyyko9xVZPIJBJPy9roymoyFnPShc1kXqUGua0l2sLWwEmiFFxnBvIqs5wqKEQ2ZSeb3eXQh89-VK3zhppGd9SvvCoLiZDxVAby9F8SUyGKXMq0DChuUDP03g9k1XJwrR4-FYJa61QLFXSqtU4FXAWdoXP8M7-qWqr_Gr_-AnCxASjo-HA0KG_cWlXtBjKjqnv3z_wXbsaEQg</recordid><startdate>20110801</startdate><enddate>20110801</enddate><creator>Le Roux, P.</creator><creator>McKinnon, G.</creator><creator>Yen, Y.-F.</creator><creator>Fernandez, B.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope></search><sort><creationdate>20110801</creationdate><title>Realignment capability of the nCPMG sequence</title><author>Le Roux, P. ; McKinnon, G. ; Yen, Y.-F. ; Fernandez, B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Algorithms</topic><topic>Amplitudes</topic><topic>Carr–Purcell–Meiboom–Gill (CPMG)</topic><topic>Driven equilibrium Fourier transform (DEFT)</topic><topic>Electromagnetic Fields</topic><topic>Electron Spin Resonance Spectroscopy - methods</topic><topic>Indicators and Reagents</topic><topic>Magnetization</topic><topic>MLEV</topic><topic>nCPMG</topic><topic>Nutation</topic><topic>Phase modulation</topic><topic>Realignment</topic><topic>Rendering</topic><topic>Shinnar–LeRoux</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Stabilization</topic><topic>Trains</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Le Roux, P.</creatorcontrib><creatorcontrib>McKinnon, G.</creatorcontrib><creatorcontrib>Yen, Y.-F.</creatorcontrib><creatorcontrib>Fernandez, B.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of magnetic resonance (1997)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Le Roux, P.</au><au>McKinnon, G.</au><au>Yen, Y.-F.</au><au>Fernandez, B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Realignment capability of the nCPMG sequence</atitle><jtitle>Journal of magnetic resonance (1997)</jtitle><addtitle>J Magn Reson</addtitle><date>2011-08-01</date><risdate>2011</risdate><volume>211</volume><issue>2</issue><spage>121</spage><epage>133</epage><pages>121-133</pages><issn>1090-7807</issn><eissn>1096-0856</eissn><abstract>[Display omitted] ► The nCPMG sequence aims at phase insensitive generation of a long train of echoes. ► The magnetization it generates presents a symmetry property in the frequency domain. ► This is taken advantage of to determine an inverse sequence. ► A realignment of any type of magnetization at the last echo time is then possible. ► An experimental verification of this claim is presented here. The nCPMG sequence is based on a particular phase modulation of the refocusing pulse train, and was originally designed for rendering the spin echo amplitude insensitive to the initial magnetization phase. This pulse sequence has the peculiarity of being easily invertible, which enables perfect driven equilibrium experiments, in the absence of relaxation. This magnetization ‘realignment’ is effective for all three components. Hence the overall operation is transparent. Supporting theory is presented here, together with the first direct experimental proof of the claim. The experiment shows that, with the present stabilization sequence, perfect realignment is indeed made possible for a range of refocusing pulse nutation angles from 130° to 230°.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>21641245</pmid><doi>10.1016/j.jmr.2011.05.005</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1090-7807
ispartof Journal of magnetic resonance (1997), 2011-08, Vol.211 (2), p.121-133
issn 1090-7807
1096-0856
language eng
recordid cdi_proquest_miscellaneous_879103529
source ScienceDirect Journals
subjects Algorithms
Amplitudes
Carr–Purcell–Meiboom–Gill (CPMG)
Driven equilibrium Fourier transform (DEFT)
Electromagnetic Fields
Electron Spin Resonance Spectroscopy - methods
Indicators and Reagents
Magnetization
MLEV
nCPMG
Nutation
Phase modulation
Realignment
Rendering
Shinnar–LeRoux
Signal Processing, Computer-Assisted
Stabilization
Trains
title Realignment capability of the nCPMG sequence
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T23%3A42%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Realignment%20capability%20of%20the%20nCPMG%20sequence&rft.jtitle=Journal%20of%20magnetic%20resonance%20(1997)&rft.au=Le%20Roux,%20P.&rft.date=2011-08-01&rft.volume=211&rft.issue=2&rft.spage=121&rft.epage=133&rft.pages=121-133&rft.issn=1090-7807&rft.eissn=1096-0856&rft_id=info:doi/10.1016/j.jmr.2011.05.005&rft_dat=%3Cproquest_cross%3E879103529%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c385t-bde6391e528dcabfaecf14ea7f394b2c15fd91f7fd05e91965a3c04b3f5eb0763%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1266749928&rft_id=info:pmid/21641245&rfr_iscdi=true