Loading…

Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution

Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh....

Full description

Saved in:
Bibliographic Details
Published in:Hernia : the journal of hernias and abdominal wall surgery 2011-08, Vol.15 (4), p.463-468
Main Authors: Muysoms, F. E., Bontinck, J., Pletinckx, P.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03
cites cdi_FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03
container_end_page 468
container_issue 4
container_start_page 463
container_title Hernia : the journal of hernias and abdominal wall surgery
container_volume 15
creator Muysoms, F. E.
Bontinck, J.
Pletinckx, P.
description Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.
doi_str_mv 10.1007/s10029-010-0692-x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_880136263</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2409063681</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03</originalsourceid><addsrcrecordid>eNp1kMtq3TAURUVJaB7tB3QSRCYdOTmSZVnKLFzaphDIpJ0VhCwfNwq25Uh2c_P3lbl5QCATHcFZe0ssQr4wOGMA9XnKJ9cFMChAal5sP5BDxoUqNAext95lVQgN8oAcpXQHAEpI9ZEccKgqKYQ6JH82YZh67-zsw5ho6OiA6Za2-M87TLQLkfpxjnbC6Ocwou3pMjR-TfT0FuPoLY04WR8vqKUPIbZrh7PL2veJ7He2T_j5aR6T39-__dpcFdc3P35uLq8LV9YwF8op1na2YY4j8JpJJzrAqgIQsrGic-CE1E5yzXWjasugdaUthXaihQahPCZfd71TDPcLptkMPjnseztiWJJRClgpuSwzefqGvAtLHPPnjKp1VqWEyhDbQS6GlCJ2Zop-sPHRMDCreLMTb7J4s4o325w5eSpemgHbl8Sz6QzwHZDyavyL8fXl91v_A2iyjq8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>879490848</pqid></control><display><type>article</type><title>Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution</title><source>Springer Nature</source><creator>Muysoms, F. E. ; Bontinck, J. ; Pletinckx, P.</creator><creatorcontrib>Muysoms, F. E. ; Bontinck, J. ; Pletinckx, P.</creatorcontrib><description>Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.</description><identifier>ISSN: 1265-4906</identifier><identifier>EISSN: 1248-9204</identifier><identifier>DOI: 10.1007/s10029-010-0692-x</identifier><identifier>PMID: 20556448</identifier><language>eng</language><publisher>Paris: Springer-Verlag</publisher><subject>Abdominal Surgery ; Aged ; Case Report ; Female ; Hernia, Umbilical - surgery ; Herniorrhaphy - adverse effects ; Humans ; Intestinal Perforation - etiology ; Intestine, Small ; Male ; Medicine ; Medicine &amp; Public Health ; Middle Aged ; Prosthesis Failure - adverse effects ; Recurrence ; Surgical Mesh - adverse effects</subject><ispartof>Hernia : the journal of hernias and abdominal wall surgery, 2011-08, Vol.15 (4), p.463-468</ispartof><rights>Springer-Verlag 2010</rights><rights>Springer-Verlag 2011</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03</citedby><cites>FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20556448$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Muysoms, F. E.</creatorcontrib><creatorcontrib>Bontinck, J.</creatorcontrib><creatorcontrib>Pletinckx, P.</creatorcontrib><title>Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution</title><title>Hernia : the journal of hernias and abdominal wall surgery</title><addtitle>Hernia</addtitle><addtitle>Hernia</addtitle><description>Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.</description><subject>Abdominal Surgery</subject><subject>Aged</subject><subject>Case Report</subject><subject>Female</subject><subject>Hernia, Umbilical - surgery</subject><subject>Herniorrhaphy - adverse effects</subject><subject>Humans</subject><subject>Intestinal Perforation - etiology</subject><subject>Intestine, Small</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Middle Aged</subject><subject>Prosthesis Failure - adverse effects</subject><subject>Recurrence</subject><subject>Surgical Mesh - adverse effects</subject><issn>1265-4906</issn><issn>1248-9204</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp1kMtq3TAURUVJaB7tB3QSRCYdOTmSZVnKLFzaphDIpJ0VhCwfNwq25Uh2c_P3lbl5QCATHcFZe0ssQr4wOGMA9XnKJ9cFMChAal5sP5BDxoUqNAext95lVQgN8oAcpXQHAEpI9ZEccKgqKYQ6JH82YZh67-zsw5ho6OiA6Za2-M87TLQLkfpxjnbC6Ocwou3pMjR-TfT0FuPoLY04WR8vqKUPIbZrh7PL2veJ7He2T_j5aR6T39-__dpcFdc3P35uLq8LV9YwF8op1na2YY4j8JpJJzrAqgIQsrGic-CE1E5yzXWjasugdaUthXaihQahPCZfd71TDPcLptkMPjnseztiWJJRClgpuSwzefqGvAtLHPPnjKp1VqWEyhDbQS6GlCJ2Zop-sPHRMDCreLMTb7J4s4o325w5eSpemgHbl8Sz6QzwHZDyavyL8fXl91v_A2iyjq8</recordid><startdate>20110801</startdate><enddate>20110801</enddate><creator>Muysoms, F. E.</creator><creator>Bontinck, J.</creator><creator>Pletinckx, P.</creator><general>Springer-Verlag</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20110801</creationdate><title>Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution</title><author>Muysoms, F. E. ; Bontinck, J. ; Pletinckx, P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Abdominal Surgery</topic><topic>Aged</topic><topic>Case Report</topic><topic>Female</topic><topic>Hernia, Umbilical - surgery</topic><topic>Herniorrhaphy - adverse effects</topic><topic>Humans</topic><topic>Intestinal Perforation - etiology</topic><topic>Intestine, Small</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Middle Aged</topic><topic>Prosthesis Failure - adverse effects</topic><topic>Recurrence</topic><topic>Surgical Mesh - adverse effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Muysoms, F. E.</creatorcontrib><creatorcontrib>Bontinck, J.</creatorcontrib><creatorcontrib>Pletinckx, P.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>ProQuest Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Hernia : the journal of hernias and abdominal wall surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Muysoms, F. E.</au><au>Bontinck, J.</au><au>Pletinckx, P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution</atitle><jtitle>Hernia : the journal of hernias and abdominal wall surgery</jtitle><stitle>Hernia</stitle><addtitle>Hernia</addtitle><date>2011-08-01</date><risdate>2011</risdate><volume>15</volume><issue>4</issue><spage>463</spage><epage>468</epage><pages>463-468</pages><issn>1265-4906</issn><eissn>1248-9204</eissn><abstract>Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.</abstract><cop>Paris</cop><pub>Springer-Verlag</pub><pmid>20556448</pmid><doi>10.1007/s10029-010-0692-x</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1265-4906
ispartof Hernia : the journal of hernias and abdominal wall surgery, 2011-08, Vol.15 (4), p.463-468
issn 1265-4906
1248-9204
language eng
recordid cdi_proquest_miscellaneous_880136263
source Springer Nature
subjects Abdominal Surgery
Aged
Case Report
Female
Hernia, Umbilical - surgery
Herniorrhaphy - adverse effects
Humans
Intestinal Perforation - etiology
Intestine, Small
Male
Medicine
Medicine & Public Health
Middle Aged
Prosthesis Failure - adverse effects
Recurrence
Surgical Mesh - adverse effects
title Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T17%3A38%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Complications%20of%20mesh%20devices%20for%20intraperitoneal%20umbilical%20hernia%20repair:%20a%20word%20of%20caution&rft.jtitle=Hernia%20:%20the%20journal%20of%20hernias%20and%20abdominal%20wall%20surgery&rft.au=Muysoms,%20F.%20E.&rft.date=2011-08-01&rft.volume=15&rft.issue=4&rft.spage=463&rft.epage=468&rft.pages=463-468&rft.issn=1265-4906&rft.eissn=1248-9204&rft_id=info:doi/10.1007/s10029-010-0692-x&rft_dat=%3Cproquest_cross%3E2409063681%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c370t-8c81dfab1c2e02716c4f0e550046ba4fc0c469c62929b87a10dc3a349c4d0be03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=879490848&rft_id=info:pmid/20556448&rfr_iscdi=true