Loading…
Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access”
Abstract The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-genera...
Saved in:
Published in: | European journal of vascular and endovascular surgery 2011-09, Vol.42, p.S48-S54 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873 |
---|---|
cites | cdi_FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873 |
container_end_page | S54 |
container_issue | |
container_start_page | S48 |
container_title | European journal of vascular and endovascular surgery |
container_volume | 42 |
creator | Wong, V Ward, R Taylor, J Selvakumar, S How, T.V Bakran, A |
description | Abstract The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up was performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery. |
doi_str_mv | 10.1016/j.ejvs.2011.06.023 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_886915755</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S107858841100387X</els_id><sourcerecordid>886915755</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873</originalsourceid><addsrcrecordid>eNp9kc-KFDEQxhtR3HX1BTxI3zxNW0km6TSIMCw7rrAg-Ae8hXS6GtNmOmOqe2Ru-yD6cvskppnVgwdPVVDf91H1q6J4zqBiwNSrocLhQBUHxipQFXDxoDhnUvAVZ0o-zD3UeiW1Xp8VT4gGAJBMyMfFGWdaSuD8vNh_wH3y44RduUmTdwHLu9ufW-ummKjcEEXn7TL94aev5ZVN4VhurQ9zwjL2iweTjwcc40zl1tM0B4tlH1N5bXEXO2_DkXxOcg6J7m5_PS0e9TYQPruvF8Xn7dWny-vVzfu37y43NysnVCPy1pZDrxumWN843jDN21a1CkTT1A1ahrYXjbNiDbLuZL8Gke_RrcC6U7WuxUXx8pS7T_H7jDSZnSeHIdgR865Ga9UwWUuZlfykdCkSJexNJrKz6WgYmAW0GcwC2iygDSiTQWfTi_v4ud1h99fyh2wWvD4JMB958JgMOY-jw84ndJPpov9__pt_7C740TsbvuERaYhzGjM-wwxxA-bj8url04wBCF1_Eb8Bf7-mJQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>886915755</pqid></control><display><type>article</type><title>Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access”</title><source>ScienceDirect Freedom Collection 2022-2024</source><creator>Wong, V ; Ward, R ; Taylor, J ; Selvakumar, S ; How, T.V ; Bakran, A</creator><creatorcontrib>Wong, V ; Ward, R ; Taylor, J ; Selvakumar, S ; How, T.V ; Bakran, A</creatorcontrib><description>Abstract The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up was performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery.</description><identifier>ISSN: 1078-5884</identifier><identifier>EISSN: 1532-2165</identifier><identifier>DOI: 10.1016/j.ejvs.2011.06.023</identifier><identifier>PMID: 21855022</identifier><language>eng</language><publisher>England: Elsevier Ltd</publisher><subject>Blood flow ; Cephalic vein ; Duplex ultrasound ; Radial artery ; Size ; Surgery</subject><ispartof>European journal of vascular and endovascular surgery, 2011-09, Vol.42, p.S48-S54</ispartof><rights>2011</rights><rights>Copyright © 2011. Published by Elsevier Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873</citedby><cites>FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21855022$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wong, V</creatorcontrib><creatorcontrib>Ward, R</creatorcontrib><creatorcontrib>Taylor, J</creatorcontrib><creatorcontrib>Selvakumar, S</creatorcontrib><creatorcontrib>How, T.V</creatorcontrib><creatorcontrib>Bakran, A</creatorcontrib><title>Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access”</title><title>European journal of vascular and endovascular surgery</title><addtitle>Eur J Vasc Endovasc Surg</addtitle><description>Abstract The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up was performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery.</description><subject>Blood flow</subject><subject>Cephalic vein</subject><subject>Duplex ultrasound</subject><subject>Radial artery</subject><subject>Size</subject><subject>Surgery</subject><issn>1078-5884</issn><issn>1532-2165</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kc-KFDEQxhtR3HX1BTxI3zxNW0km6TSIMCw7rrAg-Ae8hXS6GtNmOmOqe2Ru-yD6cvskppnVgwdPVVDf91H1q6J4zqBiwNSrocLhQBUHxipQFXDxoDhnUvAVZ0o-zD3UeiW1Xp8VT4gGAJBMyMfFGWdaSuD8vNh_wH3y44RduUmTdwHLu9ufW-ummKjcEEXn7TL94aev5ZVN4VhurQ9zwjL2iweTjwcc40zl1tM0B4tlH1N5bXEXO2_DkXxOcg6J7m5_PS0e9TYQPruvF8Xn7dWny-vVzfu37y43NysnVCPy1pZDrxumWN843jDN21a1CkTT1A1ahrYXjbNiDbLuZL8Gke_RrcC6U7WuxUXx8pS7T_H7jDSZnSeHIdgR865Ga9UwWUuZlfykdCkSJexNJrKz6WgYmAW0GcwC2iygDSiTQWfTi_v4ud1h99fyh2wWvD4JMB958JgMOY-jw84ndJPpov9__pt_7C740TsbvuERaYhzGjM-wwxxA-bj8url04wBCF1_Eb8Bf7-mJQ</recordid><startdate>201109</startdate><enddate>201109</enddate><creator>Wong, V</creator><creator>Ward, R</creator><creator>Taylor, J</creator><creator>Selvakumar, S</creator><creator>How, T.V</creator><creator>Bakran, A</creator><general>Elsevier Ltd</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201109</creationdate><title>Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access”</title><author>Wong, V ; Ward, R ; Taylor, J ; Selvakumar, S ; How, T.V ; Bakran, A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Blood flow</topic><topic>Cephalic vein</topic><topic>Duplex ultrasound</topic><topic>Radial artery</topic><topic>Size</topic><topic>Surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wong, V</creatorcontrib><creatorcontrib>Ward, R</creatorcontrib><creatorcontrib>Taylor, J</creatorcontrib><creatorcontrib>Selvakumar, S</creatorcontrib><creatorcontrib>How, T.V</creatorcontrib><creatorcontrib>Bakran, A</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of vascular and endovascular surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wong, V</au><au>Ward, R</au><au>Taylor, J</au><au>Selvakumar, S</au><au>How, T.V</au><au>Bakran, A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access”</atitle><jtitle>European journal of vascular and endovascular surgery</jtitle><addtitle>Eur J Vasc Endovasc Surg</addtitle><date>2011-09</date><risdate>2011</risdate><volume>42</volume><spage>S48</spage><epage>S54</epage><pages>S48-S54</pages><issn>1078-5884</issn><eissn>1532-2165</eissn><abstract>Abstract The radiocephalic arteriovenous fistula remains the method of choice for haemodialysis access. In order to assess their suitability for fistula formation, the radial arteries and cephalic veins were examined preoperatively by ultrasound colour flow scanner in conjunction with a pulse-generated run-off system. Intraoperative blood flow was measured after construction of the fistulae. Post-operative follow-up was performed at various intervals to monitor the development of the fistulae. Radial artery and cephalic vein diameter less than 1.6 mm was associated with early fistula failure. The intraoperative fistula blood flow did not correlate with the outcome of the operation probably due to vessel spasm from manipulation. However, blood flow velocities measured non-invasively 1 day after the operation were significantly lower in fistulae that failed early compared with those that were adequate for haemodialysis. Most of the increase in fistula diameter and blood flow occur within the first 2 weeks of surgery.</abstract><cop>England</cop><pub>Elsevier Ltd</pub><pmid>21855022</pmid><doi>10.1016/j.ejvs.2011.06.023</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1078-5884 |
ispartof | European journal of vascular and endovascular surgery, 2011-09, Vol.42, p.S48-S54 |
issn | 1078-5884 1532-2165 |
language | eng |
recordid | cdi_proquest_miscellaneous_886915755 |
source | ScienceDirect Freedom Collection 2022-2024 |
subjects | Blood flow Cephalic vein Duplex ultrasound Radial artery Size Surgery |
title | Reprinted Article “Factors Associated with Early Failure of Arteriovenous Fistulae for Haemodialysis Access” |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T03%3A18%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reprinted%20Article%20%E2%80%9CFactors%20Associated%20with%20Early%20Failure%20of%20Arteriovenous%20Fistulae%20for%20Haemodialysis%20Access%E2%80%9D&rft.jtitle=European%20journal%20of%20vascular%20and%20endovascular%20surgery&rft.au=Wong,%20V&rft.date=2011-09&rft.volume=42&rft.spage=S48&rft.epage=S54&rft.pages=S48-S54&rft.issn=1078-5884&rft.eissn=1532-2165&rft_id=info:doi/10.1016/j.ejvs.2011.06.023&rft_dat=%3Cproquest_cross%3E886915755%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3693-58a20f89161f9c29182bb6b6039979ea1eaf39ca34057d5f4030228b3e7d67873%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=886915755&rft_id=info:pmid/21855022&rfr_iscdi=true |