Loading…

Reliability, standard error, and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain

Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable asses...

Full description

Saved in:
Bibliographic Details
Published in:The journal of orthopaedic and sports physical therapy 2011-09, Vol.41 (9), p.644-650
Main Authors: Walton, David M, Macdermid, Joy C, Nielson, Warren, Teasell, Robert W, Chiasson, Marco, Brown, Lauren
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.
ISSN:0190-6011
1938-1344
DOI:10.2519/jospt.2011.3666