Loading…

3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows

A new method is proposed to reconstruct and analyze the left ventricle (LV) from multiple acoustic window three-dimensional (3-D) ultrasound acquired using a transthoracic 3-D rotational probe. Prior research in this area has been based on one acoustic window acquisition. However, the data suffers f...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on medical imaging 2002-09, Vol.21 (9), p.1051-1058
Main Authors: Xujiong Ye, Noble, J.A., Atkinson, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23
cites cdi_FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23
container_end_page 1058
container_issue 9
container_start_page 1051
container_title IEEE transactions on medical imaging
container_volume 21
creator Xujiong Ye
Noble, J.A.
Atkinson, D.
description A new method is proposed to reconstruct and analyze the left ventricle (LV) from multiple acoustic window three-dimensional (3-D) ultrasound acquired using a transthoracic 3-D rotational probe. Prior research in this area has been based on one acoustic window acquisition. However, the data suffers from several limitations that degrade the reconstruction and reduce the clinical value of interpretation, such as the presence of shadow due to bone (ribs) and air (in the lungs) and motion of the probe during the acquisition. In this paper, we show how to overcome these limitations by automatically fusing information from multiple acoustic window sparse-view acquisitions and using a position sensor to track the probe in real time. Geometric constraints of the object shape, and spatiotemporal information relating to the image acquisition process, are used in new algorithms for 1) grouping endocardial edge cues from an initial image segmentation and 2) defining a novel reconstruction method that utilizes information from multiple acoustic windows. The new method has been validated on a phantom and three real heart data sets. In the phantom study, one finger of a latex glove was scanned from two acoustic windows and reconstructed using the new method. The volume error was measured to be less than 4%. In the clinical case study, 3-D ultrasound and magnetic resonance imaging (MRI) scanning were performed on the same healthy volunteers. Quantitative ejection fractions (EFs) and volume-time curves over a cardiac cycle were estimated using the new method and compared to cardiac MRI measurements. This showed that the new method agrees better with MRI measurements than the previous approach we have developed based on a single acoustic window. The EF errors of the new method with respect to MRI measurements were less than 6%. A more extensive clinical validation is required to establish whether these promising first results translate to a method suitable for routine clinical use.
doi_str_mv 10.1109/TMI.2002.804436
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_miscellaneous_888099098</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>1166634</ieee_id><sourcerecordid>72842570</sourcerecordid><originalsourceid>FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23</originalsourceid><addsrcrecordid>eNqF0s2L1DAYBvAgijuOnj0IEgQ_Lp3Nd9Kj7K66sOJlBW8lTd84WdpmNmld5r83ZQYGPKynQPPrw0N4EHpNyYZSUp_ffr_eMELYxhAhuHqCVlRKUzEpfj1FK8K0qQhR7Ay9yPmOECokqZ-jM8qkEkbzFdrz6hL7BLC1Y4fBbaOzqQvxd7K77R77mLCdpzjYKTjcg5_wHxinFFwPOIGLY57S7KYQR7wE2NH2-xwybm2GDpevw9xPYVe0dXHOS8pDGLv4kF-iZ972GV4dzzX6-eXq9uJbdfPj6_XF55vKSc6mSvKagqOtE9Z2rPXWUW4pADfOKaJ9KzSXLVOdooxJpjzhnlNfF2O47Bhfo4-H3F2K9zPkqRlCdtD3doTSqDHGkLomtSnyw6NSMyOY1OS_kBlaS1KKrdGnRyFVmgouqOGFvvuH3sU5ledcGgqhhSZLw_MDcinmnMA3uxQGm_YNJc0yiKYMolkG0RwGUf54e4yd2wG6kz8uoID3R2Czs71PdnQhn5wQShNaF_fm4AIAnK6pUooL_hfslMcn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>884474708</pqid></control><display><type>article</type><title>3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Xujiong Ye ; Noble, J.A. ; Atkinson, D.</creator><creatorcontrib>Xujiong Ye ; Noble, J.A. ; Atkinson, D.</creatorcontrib><description>A new method is proposed to reconstruct and analyze the left ventricle (LV) from multiple acoustic window three-dimensional (3-D) ultrasound acquired using a transthoracic 3-D rotational probe. Prior research in this area has been based on one acoustic window acquisition. However, the data suffers from several limitations that degrade the reconstruction and reduce the clinical value of interpretation, such as the presence of shadow due to bone (ribs) and air (in the lungs) and motion of the probe during the acquisition. In this paper, we show how to overcome these limitations by automatically fusing information from multiple acoustic window sparse-view acquisitions and using a position sensor to track the probe in real time. Geometric constraints of the object shape, and spatiotemporal information relating to the image acquisition process, are used in new algorithms for 1) grouping endocardial edge cues from an initial image segmentation and 2) defining a novel reconstruction method that utilizes information from multiple acoustic windows. The new method has been validated on a phantom and three real heart data sets. In the phantom study, one finger of a latex glove was scanned from two acoustic windows and reconstructed using the new method. The volume error was measured to be less than 4%. In the clinical case study, 3-D ultrasound and magnetic resonance imaging (MRI) scanning were performed on the same healthy volunteers. Quantitative ejection fractions (EFs) and volume-time curves over a cardiac cycle were estimated using the new method and compared to cardiac MRI measurements. This showed that the new method agrees better with MRI measurements than the previous approach we have developed based on a single acoustic window. The EF errors of the new method with respect to MRI measurements were less than 6%. A more extensive clinical validation is required to establish whether these promising first results translate to a method suitable for routine clinical use.</description><identifier>ISSN: 0278-0062</identifier><identifier>EISSN: 1558-254X</identifier><identifier>DOI: 10.1109/TMI.2002.804436</identifier><identifier>PMID: 12564873</identifier><identifier>CODEN: ITMID4</identifier><language>eng</language><publisher>New York, NY: IEEE</publisher><subject>Acoustic measurements ; Acoustics ; Acquisitions ; Algorithms ; Biological and medical sciences ; Degradation ; Echocardiography ; Echocardiography, Three-Dimensional ; Error analysis ; Errors ; Humans ; Image Processing, Computer-Assisted ; Image reconstruction ; Imaging phantoms ; Magnetic Resonance Imaging ; Marketing ; Medical sciences ; Phantoms, Imaging ; Probes ; Reconstruction ; Studies ; Ultrasonic imaging ; Ultrasonic variables measurement ; Ultrasound ; Ventricular Function, Left - physiology ; Volume measurement</subject><ispartof>IEEE transactions on medical imaging, 2002-09, Vol.21 (9), p.1051-1058</ispartof><rights>2003 INIST-CNRS</rights><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2002</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23</citedby><cites>FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/1166634$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,778,782,27907,27908,54779</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=14467019$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/12564873$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Xujiong Ye</creatorcontrib><creatorcontrib>Noble, J.A.</creatorcontrib><creatorcontrib>Atkinson, D.</creatorcontrib><title>3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows</title><title>IEEE transactions on medical imaging</title><addtitle>TMI</addtitle><addtitle>IEEE Trans Med Imaging</addtitle><description>A new method is proposed to reconstruct and analyze the left ventricle (LV) from multiple acoustic window three-dimensional (3-D) ultrasound acquired using a transthoracic 3-D rotational probe. Prior research in this area has been based on one acoustic window acquisition. However, the data suffers from several limitations that degrade the reconstruction and reduce the clinical value of interpretation, such as the presence of shadow due to bone (ribs) and air (in the lungs) and motion of the probe during the acquisition. In this paper, we show how to overcome these limitations by automatically fusing information from multiple acoustic window sparse-view acquisitions and using a position sensor to track the probe in real time. Geometric constraints of the object shape, and spatiotemporal information relating to the image acquisition process, are used in new algorithms for 1) grouping endocardial edge cues from an initial image segmentation and 2) defining a novel reconstruction method that utilizes information from multiple acoustic windows. The new method has been validated on a phantom and three real heart data sets. In the phantom study, one finger of a latex glove was scanned from two acoustic windows and reconstructed using the new method. The volume error was measured to be less than 4%. In the clinical case study, 3-D ultrasound and magnetic resonance imaging (MRI) scanning were performed on the same healthy volunteers. Quantitative ejection fractions (EFs) and volume-time curves over a cardiac cycle were estimated using the new method and compared to cardiac MRI measurements. This showed that the new method agrees better with MRI measurements than the previous approach we have developed based on a single acoustic window. The EF errors of the new method with respect to MRI measurements were less than 6%. A more extensive clinical validation is required to establish whether these promising first results translate to a method suitable for routine clinical use.</description><subject>Acoustic measurements</subject><subject>Acoustics</subject><subject>Acquisitions</subject><subject>Algorithms</subject><subject>Biological and medical sciences</subject><subject>Degradation</subject><subject>Echocardiography</subject><subject>Echocardiography, Three-Dimensional</subject><subject>Error analysis</subject><subject>Errors</subject><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Image reconstruction</subject><subject>Imaging phantoms</subject><subject>Magnetic Resonance Imaging</subject><subject>Marketing</subject><subject>Medical sciences</subject><subject>Phantoms, Imaging</subject><subject>Probes</subject><subject>Reconstruction</subject><subject>Studies</subject><subject>Ultrasonic imaging</subject><subject>Ultrasonic variables measurement</subject><subject>Ultrasound</subject><subject>Ventricular Function, Left - physiology</subject><subject>Volume measurement</subject><issn>0278-0062</issn><issn>1558-254X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNqF0s2L1DAYBvAgijuOnj0IEgQ_Lp3Nd9Kj7K66sOJlBW8lTd84WdpmNmld5r83ZQYGPKynQPPrw0N4EHpNyYZSUp_ffr_eMELYxhAhuHqCVlRKUzEpfj1FK8K0qQhR7Ay9yPmOECokqZ-jM8qkEkbzFdrz6hL7BLC1Y4fBbaOzqQvxd7K77R77mLCdpzjYKTjcg5_wHxinFFwPOIGLY57S7KYQR7wE2NH2-xwybm2GDpevw9xPYVe0dXHOS8pDGLv4kF-iZ972GV4dzzX6-eXq9uJbdfPj6_XF55vKSc6mSvKagqOtE9Z2rPXWUW4pADfOKaJ9KzSXLVOdooxJpjzhnlNfF2O47Bhfo4-H3F2K9zPkqRlCdtD3doTSqDHGkLomtSnyw6NSMyOY1OS_kBlaS1KKrdGnRyFVmgouqOGFvvuH3sU5ledcGgqhhSZLw_MDcinmnMA3uxQGm_YNJc0yiKYMolkG0RwGUf54e4yd2wG6kz8uoID3R2Czs71PdnQhn5wQShNaF_fm4AIAnK6pUooL_hfslMcn</recordid><startdate>20020901</startdate><enddate>20020901</enddate><creator>Xujiong Ye</creator><creator>Noble, J.A.</creator><creator>Atkinson, D.</creator><general>IEEE</general><general>Institute of Electrical and Electronics Engineers</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>RIA</scope><scope>RIE</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>NAPCQ</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20020901</creationdate><title>3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows</title><author>Xujiong Ye ; Noble, J.A. ; Atkinson, D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Acoustic measurements</topic><topic>Acoustics</topic><topic>Acquisitions</topic><topic>Algorithms</topic><topic>Biological and medical sciences</topic><topic>Degradation</topic><topic>Echocardiography</topic><topic>Echocardiography, Three-Dimensional</topic><topic>Error analysis</topic><topic>Errors</topic><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Image reconstruction</topic><topic>Imaging phantoms</topic><topic>Magnetic Resonance Imaging</topic><topic>Marketing</topic><topic>Medical sciences</topic><topic>Phantoms, Imaging</topic><topic>Probes</topic><topic>Reconstruction</topic><topic>Studies</topic><topic>Ultrasonic imaging</topic><topic>Ultrasonic variables measurement</topic><topic>Ultrasound</topic><topic>Ventricular Function, Left - physiology</topic><topic>Volume measurement</topic><toplevel>online_resources</toplevel><creatorcontrib>Xujiong Ye</creatorcontrib><creatorcontrib>Noble, J.A.</creatorcontrib><creatorcontrib>Atkinson, D.</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 1998-Present</collection><collection>IEEE Xplore</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>IEEE transactions on medical imaging</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xujiong Ye</au><au>Noble, J.A.</au><au>Atkinson, D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows</atitle><jtitle>IEEE transactions on medical imaging</jtitle><stitle>TMI</stitle><addtitle>IEEE Trans Med Imaging</addtitle><date>2002-09-01</date><risdate>2002</risdate><volume>21</volume><issue>9</issue><spage>1051</spage><epage>1058</epage><pages>1051-1058</pages><issn>0278-0062</issn><eissn>1558-254X</eissn><coden>ITMID4</coden><abstract>A new method is proposed to reconstruct and analyze the left ventricle (LV) from multiple acoustic window three-dimensional (3-D) ultrasound acquired using a transthoracic 3-D rotational probe. Prior research in this area has been based on one acoustic window acquisition. However, the data suffers from several limitations that degrade the reconstruction and reduce the clinical value of interpretation, such as the presence of shadow due to bone (ribs) and air (in the lungs) and motion of the probe during the acquisition. In this paper, we show how to overcome these limitations by automatically fusing information from multiple acoustic window sparse-view acquisitions and using a position sensor to track the probe in real time. Geometric constraints of the object shape, and spatiotemporal information relating to the image acquisition process, are used in new algorithms for 1) grouping endocardial edge cues from an initial image segmentation and 2) defining a novel reconstruction method that utilizes information from multiple acoustic windows. The new method has been validated on a phantom and three real heart data sets. In the phantom study, one finger of a latex glove was scanned from two acoustic windows and reconstructed using the new method. The volume error was measured to be less than 4%. In the clinical case study, 3-D ultrasound and magnetic resonance imaging (MRI) scanning were performed on the same healthy volunteers. Quantitative ejection fractions (EFs) and volume-time curves over a cardiac cycle were estimated using the new method and compared to cardiac MRI measurements. This showed that the new method agrees better with MRI measurements than the previous approach we have developed based on a single acoustic window. The EF errors of the new method with respect to MRI measurements were less than 6%. A more extensive clinical validation is required to establish whether these promising first results translate to a method suitable for routine clinical use.</abstract><cop>New York, NY</cop><pub>IEEE</pub><pmid>12564873</pmid><doi>10.1109/TMI.2002.804436</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0278-0062
ispartof IEEE transactions on medical imaging, 2002-09, Vol.21 (9), p.1051-1058
issn 0278-0062
1558-254X
language eng
recordid cdi_proquest_miscellaneous_888099098
source IEEE Electronic Library (IEL) Journals
subjects Acoustic measurements
Acoustics
Acquisitions
Algorithms
Biological and medical sciences
Degradation
Echocardiography
Echocardiography, Three-Dimensional
Error analysis
Errors
Humans
Image Processing, Computer-Assisted
Image reconstruction
Imaging phantoms
Magnetic Resonance Imaging
Marketing
Medical sciences
Phantoms, Imaging
Probes
Reconstruction
Studies
Ultrasonic imaging
Ultrasonic variables measurement
Ultrasound
Ventricular Function, Left - physiology
Volume measurement
title 3-D freehand echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T21%3A40%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3-D%20freehand%20echocardiography%20for%20automatic%20left%20ventricle%20reconstruction%20and%20analysis%20based%20on%20multiple%20acoustic%20windows&rft.jtitle=IEEE%20transactions%20on%20medical%20imaging&rft.au=Xujiong%20Ye&rft.date=2002-09-01&rft.volume=21&rft.issue=9&rft.spage=1051&rft.epage=1058&rft.pages=1051-1058&rft.issn=0278-0062&rft.eissn=1558-254X&rft.coden=ITMID4&rft_id=info:doi/10.1109/TMI.2002.804436&rft_dat=%3Cproquest_ieee_%3E72842570%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c532t-5391ec1bc4aad2bfac13a1ee38cc607fb4735b26d6122526f03f31f9a1e835d23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=884474708&rft_id=info:pmid/12564873&rft_ieee_id=1166634&rfr_iscdi=true